Literature DB >> 28759793

Modelling recovery of ammonium from urine by electro-concentration in a 3-chamber cell.

Emma Thompson Brewster1, Johannes Jermakka2, Stefano Freguia1, Damien J Batstone3.   

Abstract

Electro-concentration enables treatment and nutrient recovery from source-separated urine, and is a potential technology for on-site treatment using a 3 compartment configuration that has anode, cathode and middle concentrate compartments. There is a particular focus on driving concentration towards the precipitation threshold in the concentrate compartment to generate solid ammonium salts, including ammonium bicarbonate. To evaluate controlling mechanisms and the feasibility of achieving high concentrations, a dynamic mechanistic model was developed and validated using experiments with synthetic urine. It was identified that high concentrations are prevented by increased back diffusion (diffusion from the middle chamber to the anolyte and catholyte) due to large concentration gradients, and the preferential migration of protons or hydroxide ions due to a loss of buffering capacity in the anolyte and catholyte (due to pH extremes). Model-based sensitivity analysis also identified that electrolyte ion concentrations (including buffer capacity) were the main controlling mechanisms, rather than membrane or electrolyte current transfer capacity. To attain high concentrations, operation should be done using a) a high current density (however there is a maximum efficient current density); b) feed at short hydraulic retention time to ensure sufficient buffer capacity; and c) a feed high in ammonium and carbonate, not diluted, and not contaminated with other salts, such as pure ureolysed urine. Taking into account electron supply and bio-anodic buffer limitations, model testing shows at least double the aqueous concentrations observed in the experiments may be achieved by optimising simple process and operational parameters such as flow rate, current density and feed solution composition. Removal of total ammonium nitrogen (TAN) and total carbonate carbon (TCC) was between 43-57% and 39-53%, respectively. Balancing the sometimes conflicting process goals of high concentrations and removal percentage will need to be considered in further application. Future experimental work should be directed towards developing electrodes capable of higher current densities. In addition it would be desirable to use ion exchange membranes with higher resistance to water fluxes and which limit back diffusion. Future modelling work should describe osmotic and electro-osmotic water fluxes as a function of the concentration gradient across the membranes and ionic fluxes, respectively. More generalised wastewater physico-chemistry speciation models should identify best methods where relatively simple Davies activity corrections do not apply.
Copyright © 2017 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Ammonium bicarbonate; Electro-concentration; Electrochemical model; Nutrient recovery; Physicochemical model; Urine

Mesh:

Substances:

Year:  2017        PMID: 28759793     DOI: 10.1016/j.watres.2017.07.043

Source DB:  PubMed          Journal:  Water Res        ISSN: 0043-1354            Impact factor:   11.236


  2 in total

1.  Energy-Efficient Ammonia Recovery in an Up-Scaled Hydrogen Gas Recycling Electrochemical System.

Authors:  Philipp Kuntke; Mariana Rodrigues; Tom Sleutels; Michel Saakes; Hubertus V M Hamelers; Cees J N Buisman
Journal:  ACS Sustain Chem Eng       Date:  2018-05-08       Impact factor: 8.198

2.  A modelling approach to assess the long-term stability of a novel microbial/electrochemical system for the treatment of acid mine drainage.

Authors:  Emma Thompson Brewster; Guillermo Pozo; Damien J Batstone; Stefano Freguia; Pablo Ledezma
Journal:  RSC Adv       Date:  2018-05-22       Impact factor: 3.361

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.