Elastic Versus Rigid Image Registration in Magnetic Resonance Imaging-transrectal Ultrasound Fusion Prostate Biopsy: A Systematic Review and Meta-analysis.

Wulphert Venderink1, Maarten de Rooij2, J P Michiel Sedelaar3, Henkjan J Huisman2, Jurgen J Fütterer2.   

Abstract

CONTEXT: The main difference between the available magnetic resonance imaging-transrectal ultrasound (MRI-TRUS) fusion platforms for prostate biopsy is the method of image registration being either rigid or elastic. As elastic registration compensates for possible deformation caused by the introduction of an ultrasound probe for example, it is expected that it would perform better than rigid registration.
OBJECTIVE: The aim of this meta-analysis is to compare rigid with elastic registration by calculating the detection odds ratio (OR) for both subgroups. The detection OR is defined as the ratio of the odds of detecting clinically significant prostate cancer (csPCa) by MRI-TRUS fusion biopsy compared with systematic TRUS biopsy. Secondary objectives were the OR for any PCa and the OR after pooling both registration techniques. EVIDENCE ACQUISITION: The electronic databases PubMed, Embase, and Cochrane were systematically searched for relevant studies according to the Preferred Reporting Items for Systematic Review and Meta-analysis Statement. Studies comparing MRI-TRUS fusion and systematic TRUS-guided biopsies in the same patient were included. The quality assessment of included studies was performed using the Quality Assessment of Diagnostic Accuracy Studies version 2. EVIDENCE SYNTHESIS: Eleven papers describing elastic and 10 describing rigid registration were included. Meta-analysis showed an OR of csPCa for elastic and rigid registration of 1.45 (95% confidence interval [CI]: 1.21-1.73, p<0.0001) and 1.40 (95% CI: 1.13-1.75, p=0.002), respectively. No significant difference was seen between the subgroups (p=0.83). Pooling subgroups resulted in an OR of 1.43 (95% CI: 1.25-1.63, p<0.00001).
CONCLUSIONS: No significant difference was identified between rigid and elastic registration for MRI-TRUS fusion-guided biopsy in the detection of csPCa; however, both techniques detected more csPCa than TRUS-guided biopsy alone. PATIENT
SUMMARY: We did not identify any significant differences in prostate cancer detection between two distinct magnetic resonance imaging-transrectal ultrasound fusion systems which vary in their method of compensating for prostate deformation.
Copyright © 2016 European Association of Urology. Published by Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Elastic; Image registration; MRI-TRUS fusion; Prostate cancer; Rigid

Mesh:

Year:  2016        PMID: 28753777     DOI: 10.1016/j.euf.2016.07.003

Source DB:  PubMed          Journal:  Eur Urol Focus        ISSN: 2405-4569


  15 in total

Review 1.  Techniques and Outcomes of MRI-TRUS Fusion Prostate Biopsy.

Authors:  Masatomo Kaneko; Dordaneh Sugano; Amir H Lebastchi; Vinay Duddalwar; Jamal Nabhani; Christopher Haiman; Inderbir S Gill; Giovanni E Cacciamani; Andre Luis Abreu
Journal:  Curr Urol Rep       Date:  2021-03-22       Impact factor: 3.092

Review 2.  [Fusion biopsies for primary diagnosis of prostate cancer : Implementation, benefits, and clinical aspects].

Authors:  L Püllen; B Hadaschik; D Eberli; T H Kuru
Journal:  Urologe A       Date:  2019-05       Impact factor: 0.639

3.  Comparison of Elastic and Rigid Registration during Magnetic Resonance Imaging/Ultrasound Fusion-Guided Prostate Biopsy: A Multi-Operator Phantom Study.

Authors:  Graham R Hale; Marcin Czarniecki; Alexis Cheng; Jonathan B Bloom; Reza Seifabadi; Samuel A Gold; Kareem N Rayn; Vikram K Sabarwal; Sherif Mehralivand; Peter L Choyke; Baris Turkbey; Brad Wood; Peter A Pinto
Journal:  J Urol       Date:  2018-06-22       Impact factor: 7.450

4.  [Importance of magnetic resonance imaging/ultrasound-guided fusion biopsy for the detection and monitoring of prostate cancer].

Authors:  R Ganzer; W Brummeisl; F S Siokou; R Scheck; T Franz; P Ho-Thi; A Mangold
Journal:  Urologe A       Date:  2019-12       Impact factor: 0.639

5.  Usability and diagnostic accuracy of different MRI/ultrasound-guided fusion biopsy systems for the detection of clinically significant and insignificant prostate cancer: a prospective cohort study.

Authors:  Ioannis Sokolakis; Nikolaos Pyrgidis; Lukas Koneval; Markus Krebs; Annette Thurner; Hubert Kübler; Georgios Hatzichristodoulou
Journal:  World J Urol       Date:  2021-06-17       Impact factor: 4.226

6.  Prostate cancer detection by targeted prostate biopsy using the 3D Navigo system: a prospective study.

Authors:  Alexandre Magnier; Cosmina Nedelcu; Samuel Chelly; Marie-Christine Rousselet-Chapeau; Abdel Rahmene Azzouzi; Souhil Lebdai
Journal:  Abdom Radiol (NY)       Date:  2021-04-15

Review 7.  MRI-targeted prostate biopsy: the next step forward!

Authors:  Emanuel Darius Cata; Iulia Andras; Teodora Telecan; Attila Tamas-Szora; Radu-Tudor Coman; Dan-Vasile Stanca; Ioan Coman; Nicolae Crisan
Journal:  Med Pharm Rep       Date:  2021-04-29

8.  Analyzing the learning curves of a novice and an experienced urologist for transrectal magnetic resonance imaging-ultrasound fusion prostate biopsy.

Authors:  Emanuel Darius Cata; Charles Van Praet; Iulia Andras; Pierre Kadula; Razvan Ognean; Maximilian Buzoianu; Daniel Leucuta; Cosmin Caraiani; Attila Tamas-Szora; Karel Decaestecker; Ioan Coman; Nicolae Crisan
Journal:  Transl Androl Urol       Date:  2021-05

Review 9.  Magnetic resonance imaging-transrectal ultrasound fusion image-guided prostate biopsy: Current status of the cancer detection and the prospects of tailor-made medicine of the prostate cancer.

Authors:  Sunao Shoji
Journal:  Investig Clin Urol       Date:  2018-12-27

Review 10.  The challenge of prostate biopsy guidance in the era of mpMRI detected lesion: ultrasound-guided versus in-bore biopsy.

Authors:  Auke Jager; Joan C Vilanova; Massimo Michi; Hessel Wijkstra; Jorg R Oddens
Journal:  Br J Radiol       Date:  2021-07-29       Impact factor: 3.039

View more