Literature DB >> 28751181

Short implants (6mm) vs. vertical bone augmentation and standard-length implants (≥9mm) in atrophic posterior mandibles: a 5-year retrospective study.

F Pieri1, C Forlivesi2, E Caselli3, G Corinaldesi4.   

Abstract

This retrospective study compared the 5-year clinical and radiographic outcomes of short implants (6 mm) (short group), and standard-length implants (≥9mm) placed after a vertical augmentation with autologous bone blocks (augmentation group), supporting partial fixed prostheses in the posterior mandible. Forty-five partially edentulous patients were enrolled in the study and evaluated after 5 years: 22 (51 implants) in the augmentation group and 23 (46 implants) in the short group. Eight surgical complications occurred in the augmentation group versus none in the short group (P=0.003). One short implant failed before loading and one standard-length implant failed after 4 years because of peri-implantitis (P=1.0). Eight biological and two prosthetic complications occurred in the augmentation group vs. three biological and three prosthetic complications in the short group (P=0.09 and P=1.0, respectively). A mean marginal bone loss of 1.61±1.12mm in the augmentation group and 0.68±0.68mm in the short group was found (P=0.002). Within the limitations of this study, both techniques resulted in successful clinical results after 5 years, but short implants exhibited less surgical complications and marginal bone loss than standard-length implants placed in augmented bone.
Copyright © 2017 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  atrophic mandible; bone graft; short dental implants; vertical augmentation

Mesh:

Substances:

Year:  2017        PMID: 28751181     DOI: 10.1016/j.ijom.2017.07.005

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Surg        ISSN: 0901-5027            Impact factor:   2.789


  7 in total

1.  Influence of Implant Tilting and Length on the Biomechanics of Single-Tooth Restoration: A Finite Element Analysis in Atrophic Mandible.

Authors:  Eduardo Anitua; Naiara Larrazabal Saez de Ibarra; Iñigo Morales Martín; Luis Saracho Rotaeche
Journal:  Dent J (Basel)       Date:  2022-05-06

2.  Internal oblique line implants in severe mandibular atrophies.

Authors:  Argimiro Hernández-Suarez; Luis-Guillermo Oliveros-López; María-Ángeles Serrera-Figallo; Celia Vázquez-Pachón; Daniel Torres-Lagares; José-Luis Gutiérrez-Pérez
Journal:  J Clin Exp Dent       Date:  2020-12-01

Review 3.  Prosthetic Rehabilitation of the Partially Edentulous Atrophic Posterior Mandible with Short Implants (≤ 8 mm) Compared with the Sandwich Osteotomy and Delayed Placement of Standard Length Implants (> 8 mm): a Systematic Review.

Authors:  Thomas Starch-Jensen; Helle Baungaard Nielsen
Journal:  J Oral Maxillofac Res       Date:  2018-06-29

4.  Prospective, Clinical Pilot Study with Eleven 4-Mm Extra-Short Implants Splinted to Longer Implants for Posterior Maxilla Rehabilitation.

Authors:  Daniel Torassa; Pablo Naldini; José Luis Calvo-Guirado; Enrique Fernández-Bodereau
Journal:  J Clin Med       Date:  2020-01-28       Impact factor: 4.241

5.  Single crown restorations supported by 6-mm implants in the resorbed posterior mandible: A five-year prospective case series.

Authors:  Felix L Guljé; Gerry M Raghoebar; Arjan Vissink; Henny J A Meijer
Journal:  Clin Implant Dent Relat Res       Date:  2019-07-28       Impact factor: 3.932

6.  Principles of biomechanics in oral implantology.

Authors:  Avram Manea; Simion Bran; Cristian Dinu; Horatiu Rotaru; Ioan Barbur; Bogdan Crisan; Gabriel Armencea; Florin Onisor; Madalina Lazar; Daniel Ostas; Mihaela Baciut; Sergiu Vacaras; Ileana Mitre; Liana Crisan; Ovidiu Muresan; Rares Roman; Grigore Baciut
Journal:  Med Pharm Rep       Date:  2019-12-15

7.  CT-based dentulous mandibular alveolar ridge measurements as predictors of crown-to-implant ratio for short and extra short dental implants.

Authors:  Francesco Cavallin; Stefano Sivolella; Silvia Meggiorin; Nadia Ferrarese; Amalia Lupi; Antonino Fiorino; Chiara Giraudo
Journal:  Sci Rep       Date:  2020-10-01       Impact factor: 4.379

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.