Thomas Bahmer1,2, Anne-Marie Kirsten3,4, Benjamin Waschki5,4, Klaus F Rabe5,4, Helgo Magnussen3,4, Detlef Kirsten5,4, Marco Gramm3,4, Simone Hummler6,7, Eva Brunnemer6,7, Michael Kreuter6,7, Henrik Watz3,4.
Abstract
BACKGROUND: Physical activity (PA) is associated with disease severity in idiopathic pulmonary fibrosis (IPF), but longitudinal studies evaluating its prognostic value and changes over time are lacking.Entities:
Keywords: Functional status (activity levels); Idiopathic pulmonary fibrosis; Longitudinal studies; Mortality; Physical exercise; Triaxial accelerometer
Mesh:
Substances:
Year: 2017 PMID: 28743305 PMCID: PMC5526311 DOI: 10.1186/s12890-017-0444-0
Source DB: PubMed Journal: BMC Pulm Med ISSN: 1471-2466 Impact factor: 3.317
Patient characteristics at baseline by survival status
| Characteristic | Survivors ( | Non-survivors ( |
|
|---|---|---|---|
| Description | |||
| Age, years | 65.8 (6.8) | 69.2 (8.5) | 0.14 |
| Male | 18 (69%) | 17 (85%) | 0.21 |
| BMI, kg/m2 | 28.2 (4.0) | 27.7 (4.9) | 0.67 |
| Use of Antifibrotic Therapy | 24 (92%) | 14 (70%) | 0.048 |
| LTOT | 5 (20%) | 5 (25%) | 0.69 |
| pO2 at rest, mmHg | 72.1 (8.2) | 70.2 (9.7) | 0.50 |
| Lung Function | |||
| FVC, liter | 3.1 (0.8) | 2.3 (0.7) | 0.002 |
| FVC, %pred. | 85.1 (21.4) | 64.3 (17.2) | 0.001 |
| FEV1 / FVC | 0.85 (0.06) | 0.81 (0.07) | 0.08 |
| DLCO, %pred. | 48.7 (13.5) | 35.9 (12.9) | 0.002 |
| Exercise Capacity | |||
| 6MWD, meters | 415 (128) | 299 (118) | 0.003 |
| Physical Activity | |||
| Steps per day | 6606 (3064) | 3433 (2655) | +0.001 |
| Disease Severity | |||
| GAP Score | 4 [2–4] | 5 [4–5] | 0.005 |
| GAP Stage | II [I – II] | II [II – II] | 0.02 |
| Comorbidities | |||
| Pulmonary Hypertension | 1 (4%) | 1 (5%) | 0.85 |
| Arterial Hypertension | 9 (35%) | 10 (50%) | 0.29 |
| Cardiovascular Diseasesa | 7 (27%) | 7 (35%) | 0.56 |
| Diabetes Mellitus | 1 (4%) | 4 (20%) | 0.08 |
| GERD | 6 (23%) | 2 (10%) | 0.25 |
| Lung Cancer | 0 | 1 (4%) | 0.25 |
| Depression | 1 (4%) | 0 | 0.38 |
| Mean number of comorbidities per patient ≥ 1b | 17 (65%) | 17 (85%) | 0.13 |
Data are presented as mean (SD), median [IQR] or n (%) depending on scale and distributional characteristics
Data were missing for LTOT (n = 1) and pO2 (n = 2)
Abbreviations: LTOT long-term oxygen therapy, pO partial pressure of oxygen in capillary blood analysis, FVC forced vital capacity, FEV forced expiratory volume at one second, DLCO diffusing capacity of the lung for carbon monoxide, 6MWD 6-min walking-distance, GAP Gender-Age-Physiology, GERD gastro-esophageal reflux disease
aCardiovascular diseases encompassed coronary artery disease, left heart failure or any other cardiovascular diseases, respectively
b N = 9 (35%) and n = 3 (15%) patients had no comorbidities, respectively. Nobody had ≥4 comorbidities
Fig. 1Kaplan-Meier survival curves for tertiles of baseline values of forced vital capacity (FVC %pred.) (a), diffusing capacity of the lung for carbon monoxide (DLCO %pred.) (b), 6-min walking distance (6MWD) (c) and steps per day (d) are displayed on the left. Longitudinal changes (i.e. baseline and follow-up values of survivors) of FVC %pred. (e), DLCO %pred. (f), 6MWD (g) and steps per day (h) are displayed as bar-charts on the right. In Kaplan-Meier survival curves solid lines represent the lowest tertile, dashed lines the mid tertile and dotted lines the highest tertile of the baseline values of FVC %pred. (a), DLCO %pred.(b), 6MWD (c) and steps per day (d), respectively. Censored data of surviving patients are represented as vertical dashes. P-values are presented within the single graphs. Bar-charts represent baseline (dark grey, left) and follow-up (light grey, right) data of FVC %pred. (e), DLCO %pred. (f), 6MWD (g) and steps per day (h). Comparissons between baseline and follow-up were made with paired t-tests and p-values were <0.001, 0.024, 0.055 and <0.001, respectively
Prognostic value of physical activity and established predictors of mortality in patients with IPF
| C statistic | Crude Cox regression of the raw predictors | Adjusted Cox regression of the standardized predictors | |||||||
|---|---|---|---|---|---|---|---|---|---|
| AUROC | 95% CI |
| HR | 95% CI |
| HR | 95% CI |
| |
| Lung Function | |||||||||
| FVC %pred. | 0.79 | 0.65–0.92 | 0.001 | 0.96 | 0.94–0.99 | 0.001 | 0.36 | 0.20–0.66 | 0.001 |
| DLCO %pred. | 0.78 | 0.64–0.92 | 0.001 | 0.94 | 0.91–0.98 | 0.002 | 0.33 | 0.17–0.67 | 0.002 |
| Exercise Capacity | |||||||||
| 6MWD | 0.77 | 0.63–0.91 | 0.002 | 0.96a | 0.93-0.98 | 0.003 | 0.56 | 0.37–0.87 | 0.009 |
| Physical Activity | |||||||||
| Steps per day | 0.79 | 0.65–0.92 | 0.001 | 0.97b | 0.96-0.99 | 0.002 | 0.46 | 0.26–0.82 | 0.008 |
| Disease Severity | |||||||||
| GAP Score | 0.74 | 0.59–0.89 | 0.006 | 1.63 | 1.19–2.24 | 0.003 | n/a | n/a | n/a |
Adjustment was done for sex, age and antifibrotic therapy. For standardization, all continuous variables were divided by one standard deviation
Abbreviations: AUROC area under the receiver operating characteristics, HR hazard ratio, CI confidence interval, FVC forced vital capacity, DLCO diffusing capacity of the lung for carbon monoxide, 6MWD 6-min walking-distance, GAP Gender-Age-Physiology
aCrude HR for 6MWD is reported per 10 m change. Therefore 6MWD results were divided by 10
bCrude HR for SPD is reported per 100 steps change. Therefore SPD results were divided by 100
Fig. 2Receiver operating characteristic (ROC) curves for the GAP score and the number of steps per day. The corresponding areas under the curves (AUROC) were 0.74 and 0.79, respectively
Longitudinal changes in lung function, exercise capacity and physical activity in survivors
| Characteristic | Absolute value at baseline | Absolute value at follow-up | Absolute decline (Baseline to follow-up) | Relative decline (Baseline to follow-up) | Average annual decline |
|
|---|---|---|---|---|---|---|
| FVC, liter | 3.05 (0.81) | 2.64 (0.78) | −0.41 (0.33) | 13.3% | −0.13 (0.11) | <0.001 |
| FVC, %pred. | 84.8 (22.9) | 76.1 (23.9) | −8.7 (9.6) | 10.5% | −2.8 (3.0) | <0.001 |
| DLCO, %pred. | 50.7 (13.6) | 43.5 (18.4) | −7.3 (13.3) | 14.4% | −2.2 (4.2) | 0.024 |
| 6MWD, meters | 418 (117) | 389 (132) | −29 (64) | 7.8% | −8.8 (20) | 0.055 |
| Steps per day | 6499 (3192) | 3482 (2350) | −3017 (2372) | 48.3% | −973 (743) | <0.001 |
Data are presented as mean (SD) and % for n = 23 survivors with complete physical activity data at follow-up. Differences between baseline and follow-up visit were tested by paired t-tests. Follow-up data were missing for FVC (n = 1), DLCO (n = 3), and 6MWD (n = 2)
Abbreviations: FVC forced vital capacity, DLCO diffusing capacity of the lung for carbon monoxide, 6MWD 6-min walking-distance