Assessment of diastolic function of normal fetal heart using dual-gate Doppler.

M Takano1, M Nakata1,2, S Nagasaki1,2, R Ueyama1, M Morita1,2.   

Abstract

OBJECTIVES: The ratio of mitral peak early diastolic filling to early diastolic mitral annular velocity (E/e') reflects diastolic cardiac function in adults. Dual-gate Doppler (DD) enables measurements of E/e' in the same heart beat. This study was designed to assess the utility of the DD method for measurement of fetal E/e' and determine reference ranges for normal fetuses.
METHODS: This prospective study comprised normal singleton pregnancies undergoing fetal echocardiography between 16 and 36 weeks of gestation. According to the DD method, E-wave velocity on pulsed-wave Doppler and e'-wave on tissue Doppler imaging were measured simultaneously on an apical or basal four-chamber view, and fetal E/e' was calculated. Spearman's correlation coefficient was used to assess the relationship between gestational age (GA) and E-wave and e'-wave velocities and E/e'.
RESULTS: A total of 133 pregnancies were included in this study and all E/e' measurements were successful. Significant correlation was observed between GA and both left ventricular (LV) E/e' (r s  = -0.666, P < 0.001) and right ventricular (RV) E/e' (r s  = -0.607, P < 0.001). The regression equations for bilateral E/e' were: LV-E/e' = 17.341 - 0.631GA + 0.008 × GA2 (mean ± SD, R 2  = 0.440 ± 1.333); and RV-E/e' = 19.156 - 0.794GA + 0.012GA2 (R 2  = 0.419 ± 1.329).
CONCLUSIONS: Bilateral E/e' of normal fetuses, measured using the DD method, decreased with GA, which is considered to be related to myocardial maturity. DD is a useful and convenient method for evaluating fetal E/e' in order to assess diastolic function in the prenatal period.
Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2017 ISUOG. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  E/e′; diastolic function; dual-gate Doppler method; fetal cardiac function; tissue Doppler imaging

Mesh:

Year:  2018        PMID: 28741751     DOI: 10.1002/uog.18821

Source DB:  PubMed          Journal:  Ultrasound Obstet Gynecol        ISSN: 0960-7692            Impact factor:   7.299


  4 in total

1.  Feasibility of automated fetal fractional shortening measurement with two-dimensional tracking and construction of a reference range for normal fetuses.

Authors:  Sumito Nagasaki; Masahiko Nakata; Mayumi Takano; Kento Usui; Junya Sakuma; Eijiro Hayata; Mineto Morita
Journal:  J Med Ultrason (2001)       Date:  2019-04-05       Impact factor: 1.314

2.  Comparison between conventional duplex ultrasonography and the dual-gate Doppler mode for hemodynamic measurements of the carotid arteries.

Authors:  Jeanne Hersant; Pierre Ramondou; Delphine Douillet; Stanislas Abrard; Patrick Vandeputte; François-Xavier Lapébie; Pierre Abraham; Samir Henni
Journal:  Ultrasonography       Date:  2021-11-10

3.  Assessment of fetal cardiac diastolic function of gestational diabetes mellitus using dual-gate Doppler.

Authors:  Qingsha Hou; Fang Yan; Xudong Dong; Huanling Liu; Jie Wu; Jiao Li; Yunchuan Ding
Journal:  Medicine (Baltimore)       Date:  2021-07-16       Impact factor: 1.817

4.  Obstetric ultrasound: where are we and where are we going?

Authors:  Jacques S Abramowicz
Journal:  Ultrasonography       Date:  2020-08-25