| Literature DB >> 28740939 |
Milena de Oliveira Bravo Monteiro1, Danúbia da Cunha de Sá-Caputo1,2, Eloá Moreira-Marconi1,2, Éric Heleno Freire Ferreira Frederico1,3, Cintia Renata de Sousa-Gonçalves4,1, Luciana Camargo Bernardo1, Carlos Alberto Sampaio Guimarães1, Mario Bernardo-Filho1.
Abstract
BACKGROUND: Exposure to whole body vibration exercises (WBVE), besides some biological effects, causes alterations in the concentration of some blood biomarkers. The aim of this study is to evaluate the action of vibration (10 Hz) of WBVE on the concentration of blood biomarkers in Wistar rats.Entities:
Keywords: Wistar rats; biomarkers; mechanical vibration; oscillating/vibratory platform; whole-body vibration
Mesh:
Substances:
Year: 2017 PMID: 28740939 PMCID: PMC5514436 DOI: 10.21010/ajtcam.v14i4S.2
Source DB: PubMed Journal: Afr J Tradit Complement Altern Med ISSN: 2505-0044
Effects of vibration of 10 Hz on the level of some biomarkers (some related to the liver function) in the blood of rats
| Biomarker | CG | EG | Effect size | |
|---|---|---|---|---|
| Glucose (mmol/L) | 8.00±1.72 | 7.94±1.57 | 0.9573 | 0.03 |
| CK (UI/h) | 617.2±196.26 | 337.00±42.42 | 0.0315 | 1.97 |
| Albumin (g/dl) | 3.30±0.20 | 3.70±0.89 | 0.4142 | 0.62 |
| Alkaline phosphatase (U/ml) | 120.1±20.1 | 140.3±45.62 | 0.4486 | 0.57 |
| TGP (UI/I) | 58.8±21.04 | 88.5±2.12 | 0.0308 | 1.98 |
| TGO (UI/I) | 124.8±45.9 | 458.0±53.74 | 0.0001 | 6.66 |
| γGT (UI/I) | 6.7±2.5 | 6.3±1.09 | 0.7791 | 0.20 |
CG - control group, EG - group submitted to vibration
Effects of vibration of 10 Hz on the values of some plasma biomarkers related to the lipid metabolism in the blood of rats
| Biomarker | CG | EG | Effect size | |
|---|---|---|---|---|
| Total cholesterol (mg/dl) | 43.16±11.30 | 46.67±6.81 | 0.6138 | 0.36 |
| Triglycerides (mg/dl) | 21.33±13.96 | 24.00±14.14 | 0.7971 | 0.19 |
| HDL (mg/dl) | 40.83±9.98 | 40.67±4.51 | 0.9776 | 0.02 |
| LDL (mg/dl) | 1.50±0.98 | 0.20±0.001 | 0.0379 | 1.87 |
| VLDL (mg/dl) | 4.46±1.15 | 4.80±2.82 | 0.8307 | 0.157 |
CG - control group, EG - group submitted to vibration
Effects of the vibration of 10 Hz on the biochemical values of some biomarkers related to kidney and pancreas functions
| Biomarker | CG | EG | P | Effect size |
|---|---|---|---|---|
| Lipase (µg/ml) | 4.95±0.75 | 6.40±2.19 | 0.2569 | 0.88 |
| Amylase (µg/l) | 2360.16±265.21 | 2798.33±740.81 | 0.3080 | 0.78 |
| Urea (mg/ml) | 54.83±9.02 | 54.00±10.00 | 0.9059 | 0.08 |
| Creatinine (mg/ml) | 0.36±0.08 | 0.40±0.10 | 0.5552 | 0.44 |
CG - control group, EG - group submitted to vibration
Effects of vibrations of 10 Hz on the number of white blood cells and platelets in the blood of rats
| Cell type | CG | EG | P | Effect size |
|---|---|---|---|---|
| WBC (109/L) | 4353±359 | 8000±127 | 0.0001 | 13.54 |
| Neutrophils (%) | 2.60±0.91 | 2.89±0.36 | 0.6969 | 0.41 |
| Lymphocytes (%) | 5.00±2.38 | 5.02±0.30 | 0.9872 | 0.01 |
| Monocytes (%) | 0.032±0.014 | 0.047±0.037 | 0.4770 | 0.53 |
| Eosinophils (%) | 0.037±0.019 | 0.035±0.009 | 0.8554 | 0.13 |
| Basophils (%) | 0.071±0.04 | 0.041±0.028 | 0.2651 | 0.83 |
| Platelets (103cells/ µl) | 922±152 | 1074±86 | 0.1324 | 1.23 |
CG - control group, EG - group submitted to vibration