Literature DB >> 28739417

Neutron tomographic imaging of bone-implant interface: Comparison with X-ray tomography.

Hanna Isaksson1, Sophie Le Cann2, Christina Perdikouri3, Mikael J Turunen4, Anders Kaestner5, Magnus Tägil6, Stephen A Hall7, Erika Tudisco8.   

Abstract

Metal implants, in e.g. joint replacements, are generally considered to be a success. As mechanical stability is important for the longevity of a prosthesis, the biological reaction of the bone to the mechanical loading conditions after implantation and during remodelling determines its fate. The bone reaction at the implant interface can be studied using high-resolution imaging. However, commonly used X-ray imaging suffers from image artefacts in the close proximity of metal implants, which limit the possibility to closely examine the bone at the bone-implant interface. An alternative ex vivo 3D imaging method is offered by neutron tomography. Neutrons interact with matter differently than X-rays; therefore, this study explores if neutron tomography may be used to enrich studies on bone-implant interfaces. A stainless steel screw was implanted in a rat tibia and left to integrate for 6weeks. After extracting the tibia, the bone-screw construct was imaged using X-ray and neutron tomography at different resolutions. Artefacts were visible in all X-ray images in the close proximity of the implant, which limited the ability to accurately quantify the bone around the implant. In contrast, neutron images were free of metal artefacts, enabling full analysis of the bone-implant interface. Trabecular structural bone parameters were quantified in the metaphyseal bone away from the implant using all imaging modalities. The structural bone parameters were similar for all images except for the lowest resolution neutron images. This study presents the first proof-of-concept that neutron tomographic imaging can be used for ex-vivo evaluation of bone microstructure and that it constitutes a viable, new tool to study the bone-implant interface tissue remodelling.
Copyright © 2017 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Bone; Metal implant; Neutron tomography; X-ray tomography

Mesh:

Year:  2017        PMID: 28739417     DOI: 10.1016/j.bone.2017.07.022

Source DB:  PubMed          Journal:  Bone        ISSN: 1873-2763            Impact factor:   4.398


  4 in total

Review 1.  Biomechanical behaviours of the bone-implant interface: a review.

Authors:  Xing Gao; Manon Fraulob; Guillaume Haïat
Journal:  J R Soc Interface       Date:  2019-07-31       Impact factor: 4.118

2.  Investigating the Mechanical Characteristics of Bone-Metal Implant Interface Using in situ Synchrotron Tomographic Imaging.

Authors:  Sophie Le Cann; Erika Tudisco; Mikael J Turunen; Alessandra Patera; Rajmund Mokso; Magnus Tägil; Ola Belfrage; Stephen A Hall; Hanna Isaksson
Journal:  Front Bioeng Biotechnol       Date:  2019-01-21

3.  The Hydration State of Bone Tissue Affects Contrast in Neutron Tomographic Images.

Authors:  Elin Törnquist; Sophie Le Cann; Alessandro Tengattini; Lukas Helfen; Joeri Kok; Stephen A Hall; Hanna Isaksson
Journal:  Front Bioeng Biotechnol       Date:  2022-06-17

4.  Characterizing pearls structures using X-ray phase-contrast and neutron imaging: a pilot study.

Authors:  D Micieli; D Di Martino; M Musa; L Gori; A Kaestner; A Bravin; A Mittone; R Navone; G Gorini
Journal:  Sci Rep       Date:  2018-08-14       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.