Literature DB >> 28738572

Sequential determination of nickel and cadmium in tobacco, molasses and refill solutions for e-cigarettes samples by molecular fluorescence.

María Carolina Talio1, Magdalena Alesso2, Mariano Acosta1, Verónica S Wills3, Liliana P Fernández4.   

Abstract

In this work, a new procedure was developed for separation and preconcentration of nickel(II) and cadmium(II) in several and varied tobacco samples. Tobacco samples were selected considering the main products consumed by segments of the population, in particular the age (youth) and lifestyle of the consumer. To guarantee representative samples, a randomized strategy of sampling was used. In the first step, a chemofiltration on nylon membrane is carried out employing eosin (Eo) and carbon nanotubes dispersed in sodium dodecylsulfate (SDS) solution (phosphate buffer pH 7). In this condition, Ni(II) was selectively retained on the solid support. After that, the filtrate liquid with Cd(II) was re-conditioned with acetic acid /acetate buffer solution (pH 5) and followed by detection. A spectrofluorimetric determination of both metals was carried out, on the solid support and the filtered aqueous solution, for Ni(II) and Cd(II), respectively. The solid surface fluorescence (SSF) determination was performed at λem = 545nm (λex = 515nm) for Ni(II)-Eo complex and the fluorescence of Cd(II)-Eo was quantified in aqueous solution using λem = 565nm (λex = 540nm). The calibration graphs resulted linear in a range of 0.058-29.35μgL-1 for Ni(II) and 0.124-56.20μgL-1 for Cd(II), with detection limits of 0.019 and 0.041μgL-1 (S/N = 3). The developed methodology shows good sensitivity and adequate selectivity, and it was successfully applied to the determination of trace amounts of nickel and cadmium present in tobacco samples (refill solutions for e-cigarettes, snuff used in narguille (molasses) and traditional tobacco) with satisfactory results. The new methodology was validated by ICP-MS with adequate agreement. The proposed methodology represents a novel fluorescence application to Ni(II) and Cd(II) quantification with sensitivity and accuracy similar to atomic spectroscopies, introducing for the first time the quenching effect on SSF.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Cadmium; E-cigarettes; Eosin; Luminescence; Molasses and tobacco samples; Nickel

Mesh:

Substances:

Year:  2017        PMID: 28738572     DOI: 10.1016/j.talanta.2017.06.015

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  4 in total

1.  Polystyrene-coated magnetic nanoparticles based dispersive solid phase extraction for the determination of cadmium in cigarette ash prior to slotted quartz tube flame atomic absorption spectrometry system.

Authors:  Gamze Dalgıç Bozyiğit; Yağmur Kılınç; Buse Tuğba Zaman; Dotse Selali Chormey; Sezgin Bakırdere
Journal:  Anal Sci       Date:  2022-03-27       Impact factor: 2.081

Review 2.  Analytical methods for the identification of micro/nano metals in e-cigarette emission samples: a review.

Authors:  Wafaa Waleed Al-Qaysi; Fatma H Abdulla
Journal:  Chem Zvesti       Date:  2021-08-18       Impact factor: 2.097

3.  Method Validation Approaches for Analysis of Constituents in ENDS.

Authors:  Samantha M Reilly; Tianrong Cheng; Jenna DuMond
Journal:  Tob Regul Sci       Date:  2020-07

4.  Metal/Metalloid Levels in Electronic Cigarette Liquids, Aerosols, and Human Biosamples: A Systematic Review.

Authors:  Di Zhao; Atul Aravindakshan; Markus Hilpert; Pablo Olmedo; Ana M Rule; Ana Navas-Acien; Angela Aherrera
Journal:  Environ Health Perspect       Date:  2020-03-18       Impact factor: 9.031

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.