Thermal response to firefighting activities in residential structure fires: impact of job assignment and suppression tactic.

Gavin P Horn1, Richard M Kesler1, Steve Kerber2, Kenneth W Fent3, Tad J Schroeder1, William S Scott4, Patricia C Fehling5, Bo Fernhall6, Denise L Smith1,5.   

Abstract

Firefighters' thermal burden is generally attributed to high heat loads from the fire and metabolic heat generation, which may vary between job assignments and suppression tactic employed. Utilising a full-sized residential structure, firefighters were deployed in six job assignments utilising two attack tactics (1. Water applied from the interior, or 2. Exterior water application before transitioning to the interior). Environmental temperatures decreased after water application, but more rapidly with transitional attack. Local ambient temperatures for inside operation firefighters were higher than other positions (average ~10-30 °C). Rapid elevations in skin temperature were found for all job assignments other than outside command. Neck skin temperatures for inside attack firefighters were ~0.5 °C lower when the transitional tactic was employed. Significantly higher core temperatures were measured for the outside ventilation and overhaul positions than the inside positions (~0.6-0.9 °C). Firefighters working at all fireground positions must be monitored and relieved based on intensity and duration. Practitioner Summary: Testing was done to characterise the thermal burden experienced by firefighters in different job assignments who responded to controlled residential fires (with typical furnishings) using two tactics. Ambient, skin and core temperatures varied based on job assignment and tactic employed, with rapid elevations in core temperature in many roles.

Entities:  

Keywords:  Firefighting; body temperature; core temperature; heat strain; heat stress

Mesh:

Year:  2017        PMID: 28737481     DOI: 10.1080/00140139.2017.1355072

Source DB:  PubMed          Journal:  Ergonomics        ISSN: 0014-0139            Impact factor:   2.778


  12 in total

1.  Targeted GC-MS analysis of firefighters' exhaled breath: Exploring biomarker response at the individual level.

Authors:  M Ariel Geer Wallace; Joachim D Pleil; Karen D Oliver; Donald A Whitaker; Sibel Mentese; Kenneth W Fent; Gavin P Horn
Journal:  J Occup Environ Hyg       Date:  2019-04-01       Impact factor: 2.155

2.  Development of Fireground Exposure Simulator (FES) Prop for PPE Testing and Evaluation.

Authors:  Gavin P Horn; Steve Kerber; Jeffery Lattz; Richard M Kesler; Denise L Smith; Alex Mayer; Kenneth W Fent
Journal:  Fire Technol       Date:  2020-04-24       Impact factor: 3.605

3.  Management of Firefighters' Chemical & Cardiovascular Exposure Risks on the Fireground.

Authors:  Gavin P Horn; Steve Kerber; Kenneth W Fent; Denise L Smith
Journal:  Int Fire Serv J Leadersh Manag       Date:  2020

4.  Impact of Repeated Exposure and Cleaning on Protective Properties of Structural Firefighting Turnout Gear.

Authors:  Gavin P Horn; Steve Kerber; Jessica Andrews; Richard M Kesler; Hannah Newman; Jacob W Stewart; Kenneth W Fent; Denise L Smith
Journal:  Fire Technol       Date:  2021       Impact factor: 3.605

5.  Non-targeted GC/MS analysis of exhaled breath samples: Exploring human biomarkers of exogenous exposure and endogenous response from professional firefighting activity.

Authors:  M Ariel Geer Wallace; Joachim D Pleil; Karen D Oliver; Donald A Whitaker; Sibel Mentese; Kenneth W Fent; Gavin P Horn
Journal:  J Toxicol Environ Health A       Date:  2019-03-23

6.  Firefighter hemodynamic responses to different fire training environments.

Authors:  Elizabeth C Lefferts; Alexander J Rosenberg; Georgios Grigoriadis; Sang Ouk Wee; Stephen Kerber; Kenneth W Fent; Gavin P Horn; Denise L Smith; Bo Fernhall
Journal:  Vasc Med       Date:  2021-02-19       Impact factor: 3.239

7.  Effects of firefighting hood design, laundering and doffing on smoke protection, heat stress and wearability.

Authors:  Richard M Kesler; Alex Mayer; Kenneth W Fent; I-Chen Chen; A Shawn Deaton; R Bryan Ormond; Denise L Smith; Andrea Wilkinson; Steve Kerber; Gavin P Horn
Journal:  Ergonomics       Date:  2021-02-01       Impact factor: 2.561

8.  Real-Time Thermal Modulation of High Bandwidth MOX Gas Sensors for Mobile Robot Applications.

Authors:  Yuxin Xing; Timothy A Vincent; Marina Cole; Julian W Gardner
Journal:  Sensors (Basel)       Date:  2019-03-08       Impact factor: 3.576

9.  Evaluation of a Wearable Non-Invasive Thermometer for Monitoring Ear Canal Temperature during Physically Demanding (Outdoor) Work.

Authors:  Charlotte Christina Roossien; Audy Paul Hodselmans; Ronald Heus; Michiel Felix Reneman; Gijsbertus Jacob Verkerke
Journal:  Int J Environ Res Public Health       Date:  2021-05-04       Impact factor: 3.390

10.  Characterizing exposures to flame retardants, dioxins, and furans among firefighters responding to controlled residential fires.

Authors:  Alexander C Mayer; Kenneth W Fent; I-Chen Chen; Deborah Sammons; Christine Toennis; Shirley Robertson; Steve Kerber; Gavin P Horn; Denise L Smith; Antonia M Calafat; Maria Ospina; Andreas Sjodin
Journal:  Int J Hyg Environ Health       Date:  2021-06-10       Impact factor: 7.401

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.