Literature DB >> 28736054

Low sensitivity of anion gap to detect clinically significant lactic acidosis in the emergency department.

Q Xu1, S HowlettClyne1, A Fuezery1, G S Cembrowski2.   

Abstract

INTRODUCTION: Lactic acidosis represents the pathologic accumulation of lactate and hydrogen ions. It is important to efficiently diagnose lactic acidosis as delayed treatment will lead to poor patient outcomes. As plasma lactate levels may not be rapidly available, some physicians may use elevated anion gaps to test for the need to measure lactate. All Edmonton metropolitan hospitals have Radiometer blood gas/electrolyte instruments in the ED or close by. As lactate is measured for each set of electrolytes, we were able to determine the effectiveness of a screening anion gap for lactic acidosis.
METHODS: Two years of emergency department lactates and electrolytes from Edmonton's 5 metropolitan hospitals were analyzed. We determined the sensitivity, specificity and positive predictive value of detecting an elevated lactate, defined as ≥2.5mmol/L or ≥4mmol/L.
RESULTS: Depending on the elevated anion gap cut-off and the definition of elevated lactate, between 40-80% of elevated lactates are missed. In general, the positive predictive value approaches 40% for AGs ≥12mmol/L and 60% for AGs ≥16mmol/L.
CONCLUSIONS: Anion gap is an inadequate marker of lactic acidosis. We recommend that lactate be done with each set of electrolytes and/or blood gases. In this way lactic acidosis will not be missed.
Copyright © 2017. Published by Elsevier Inc.

Entities:  

Keywords:  Anion gap; Emergency department; Lactate

Mesh:

Substances:

Year:  2017        PMID: 28736054     DOI: 10.1016/j.clinbiochem.2017.07.008

Source DB:  PubMed          Journal:  Clin Biochem        ISSN: 0009-9120            Impact factor:   3.281


  3 in total

1.  Does the Same Hyperlactatemia Cut-Off in the Context of Acute Diseases Hold the Same Meaning in Diabetes Mellitus?

Authors:  Inês H Vieira; Maja Petrova; José P Moura
Journal:  Cureus       Date:  2022-05-20

2.  Can base excess and anion gap predict lactate level in diagnosis of septic shock?

Authors:  Werapon Pongmanee; Veerapong Vattanavanit
Journal:  Open Access Emerg Med       Date:  2017-12-20

3.  False-negative diagnosis of high anion gap in patients with end-stage kidney disease.

Authors:  You Komatsuzaki; Masato Ikeda; Akihiro Shimizu; Nanae Matsuo; Yukio Maruyama; Takashi Yokoo; Hiroyuki Yamamoto; Nobuhiko Joki; Ryoichi Ando; Daijo Inaguma; Toshihiko Yamaka; Masaaki Nakayama; Fumihiko Koiwa; Shinya Kawamoto; Shigeo Negi; Takashi Shigematsu
Journal:  Sci Rep       Date:  2021-02-25       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.