Prone Percutaneous Nephrolithotomy: Does Bolster Orientation Matter?

Daniel Sagalovich1, Cecilia Besa2, Timothy Y Tran3, Haresh Thummar3, Blake Le Grand3, Bachir Taouli4, Mantu Gupta3.   

Abstract

OBJECTIVE: To assess whether horizontal vs vertical bolster orientation affects kidney position during prone percutaneous nephrolithotomy as this could impact the need for supracostal access and therefore the likelihood of pleural injury.
MATERIALS AND METHODS: In a prospective trial, 10 subjects with 20 renal units underwent magnetic resonance imaging in prone position with standard cylindrical bolsters oriented vertically and then horizontally. Vertical bolsters were placed along the lateral aspect of the chest. Horizontal bolsters were placed at the xiphoid and symphysis pubis. The position of the kidney relative to the pleura was assessed by measuring distances from the kidney upper pole to diaphragm, to the top of the first lumbar vertebra, and inferior-most rib. Nephrostomy tract length and tract proximity to adjacent organs were also measured.
RESULTS: Right and left kidney-to-diaphragm distance significantly increased with horizontal vs vertical bolsters by 3.44 cm and 1.86 cm, respectively (P = .02, P = .01). Right kidney-to-rib distance significantly increased by 2.4 cm (P = .025); left kidney-to-rib distance increased by 0.5 cm (P = .123). Right kidney-to-vertebral distance significantly increased by 2.16 cm (P = .007); left kidney-to-vertebral distance increased by 0.9 cm (P = .059). There was no significant difference in maximum access angle, overall tract length, or colon position between horizontal and vertical bolsters.
CONCLUSION: Orienting bolsters horizontally results in caudal kidney displacement without affecting access angle, overall tract length, or colon position. In comparison with vertical orientation, this may improve safety of percutaneous nephrolithotomy by decreasing the need for supracostal access and increasing the safety of supracostal access when required.
Copyright © 2017 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2017        PMID: 28733201     DOI: 10.1016/j.urology.2017.07.005

Source DB:  PubMed          Journal:  Urology        ISSN: 0090-4295            Impact factor:   2.649


  1 in total

1.  Effects of horizontal versus vertical bolster alignment on anatomical orientation of kidney as applied to prone percutaneous nephrolithotomy.

Authors:  Prashant Singh; Rishi Nayyar; Barun Bagga; Sanjay Sharma; Amlesh Seth; Prabhjot Singh; Brusabhanu Nayak
Journal:  World J Urol       Date:  2021-05-21       Impact factor: 4.226

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.