In vitro evaluation of microleakage under orthodontic brackets bonded with different adhesive systems.

Ramin Atash1, Ali Fneiche1, Sibel Cetik2, Babak Bahrami1, Alain Balon-Perin1, Maria Orellana1, Régine Glineur1.   

Abstract

OBJECTIVE: Adhesives systems have a drawback when utilized for bonding orthodontic brackets: they shrink during photopolymerization creating microleakage. The aim of this study was to assess the stability of different orthodontic adhesives around brackets and enamel.
MATERIALS AND METHODS: Sixty noncarious mandibular premolars extracted for orthodontic reasons were randomly divided into six groups of adhesives used for bonding brackets to dental enamel: NeoBond® Light Cure Adhesive Kit, Transbond™ Plus Self-Etching, Victory V-Slot APC PLUS® + Transbond™ MIP, Rely-A-Bond® Kit, Light Cure Orthodontic Adhesive Kit (OptiBond®), and Transbond™ MIP. Following bonding, all teeth underwent 2500 cycles of thermal cycling in baths ranging from 5°C to 55°C before being immersed in 2% methylene blue for 24 h. All samples were examined under a binocular microscope to assess the degree of microleakage at the "bracket-adhesive" and "adhesive-enamel" interfaces in the gingival and occlusal regions of the bracket.
RESULTS: A significant difference was found at the "occlusal bracket-adhesive" interface. The highest microleakage values were found in the occlusal region, although no significant. Microleakage was observed in all groups.
CONCLUSION: Group 2 had the highest microleakage values whereas Group 6 had the lowest values.

Entities:  

Keywords:  Adhesive; bracket bonding; microleakage; shrinkage

Year:  2017        PMID: 28729789      PMCID: PMC5502561          DOI: 10.4103/ejd.ejd_312_16

Source DB:  PubMed          Journal:  Eur J Dent


INTRODUCTION

There are several methods to prepare enamel for bonding: self-etching, which combines an etching acid and a primer in one single step, thereby reducing procedure time; “classic” etching, which involves applying a strong acid onto the enamel surface, followed by the application of a primer and a bonding agent. Another procedure is laser conditioning of the enamel, which is performed at a specified frequency and duration.[123456] One of the main drawbacks of adhesive materials is polymerization shrinkage during curing, which creates a space between the adhesive and the enamel surface, thus allowing the infiltration of bacteria, fluids, ions, and even air from the oral cavity.[78910] This phenomenon, called microleakage, could lead to secondary caries, pulpal inflammation, and the unpleasant “white spot lesions” commonly observed after orthodontic treatment.[1910111213] One of the causes of orthodontic bracket bond failure is the formation of space between the enamel and the bracket or between the bracket and the adhesive. In addition to photopolymerization shrinkage, bonding materials are exposed to temperature changes in the oral cavity caused by the ingestion of food and beverages that could also lead to volumetric changes. These events would produce fatigue in the adhesive joint, which in turn causes microleakage. Several protocols have been developed to prevent enamel demineralization and reduce bond failure. Despite these efforts, demineralization and bond failure continue to affect the outcome of orthodontic treatment. The preferred method to study microleakages in vitro continues to be thermal cycling. This method produces a thermal stress on the adhesive joint by recreating extreme temperatures in the teeth similar with those encountered in the oral environment.[914] The aim of this study was to assess and compare the stability of different orthodontic adhesive systems at the brackets and enamel junction.

MATERIALS AND METHODS

A total of sixty healthy mandibular premolars, which had been extracted for orthodontic reasons and immediately placed in normal saline solution (0.9% sodium chloride solution), were used in this study. All the teeth were then etched for 30 s with 37% phosphoric acid solution (Ormco Etching Solution, Ormco, Glendora, California) followed by 5 s of water rinsing and 5 s of air drying.[11] The prepared teeth were then randomly divided into six groups (n = 10) of different adhesive systems, which were assigned a color code [Table 1].
Table 1

Groups by adhesive

Groups by adhesive For this study, each orthodontic bracket (3M Victory series; 3M, St Paul, Minnesota) has been bonded to one tooth, particularly to the buccal surface, following manufacturer's instructions. This has been operated by a single operator. Photopolymerization was performed using the Elipar™ S10 LED Curing Light (3M ESPE, St Paul, Minnesota) at an intensity of 1200 mW/cm2, for 10 s on the mesial side and then 10 s on the distal side. Two layers of varnish were applied to the teeth based on the color code assigned to each system leaving a 1 mm margin around the edges of the bracket. Next, the teeth underwent accelerated aging by means of 2500 cycles of thermal cycling. They were alternately immersed in 5°C and 55°C baths; each bath lasted 30 s, and transferring the tooth from one bath to the other took 10 s. The teeth were then immersed in 2% methylene blue for 24 h away from light before rinsing with water and air dry. The bracket was then sectioned down the middle in a buccolingual direction using a low-speed diamond saw under continuous irrigation (Isomet® Low-Speed Saw, Springfield, Virginia). Microleakage in each sample was evaluated using a binocular microscope at 40X magnification (Olympus® SZH10, Tokyo, Japan) and an image was taken using a Canon® EOS 700D camera (Tokyo, Japan) connected to the microscope. The image obtained [Figure 1] was analyzed using ImageJ® software version 2006 (Broken Symmetry Software) which enabled measurements to be made using different tools [Figure 2]. Finally, a score was assigned to the different degrees of microleakage at the bracket-adhesive and adhesive-enamel interfaces in the occlusal and gingival regions of the bracket, as described in Table 2.
Figure 1

Cemented bracket through binocular microscope (×40)

Figure 2

Set scale and measure with ImageJ®

Table 2

Criteria and evaluation of microleakage

Cemented bracket through binocular microscope (×40) Set scale and measure with ImageJ® Criteria and evaluation of microleakage Statistical analysis was performed using IBM SPSS® Statistics software (IBM, Armonk, New York).

RESULTS

A Kruskal–Wallis test yielded a significant difference in the occlusal bracket-adhesive interface among groups depending on the type of adhesive, P = 0.033. No statistical significant difference was found between the “gingival bracket adhesive,” “occlusal adhesive enamel,” and “gingival adhesive enamel” groups (respectively, P = 0.197, 0.497, and 0.487; see Figure 3). The Score 1 was overrepresented with the “3M Transbond Plus SEP” system (adjusted residual of 2.2), while the Score 0 was overrepresented with the “3M Transbond MIP” adhesive (adjusted residual of 2.7) compared with the respective mean percentages of the Scores 1 and 0.
Figure 3

Mean scores according to each interface

Mean scores according to each interface Given that the penetration scores were only either 0 or 1, our data were analyzed by means of four contingency tables for each of the four variables. Results from the two statistical analyses (Kruskal–Wallis and Chi-squared test) were similar. The “occlusal bracket-adhesive” variable alone yielded a statistically significant Chi-squared result (P = 0.034) between type of adhesive and score, reflecting the dependence between these two variables. For the other three variables, as seen in Figure 4, there was no statistically significant difference (P = 0.232, 0.710, and 0.742, respectively).
Figure 4

Means adhesive interface scores according to each adhesive. (a) occlusal bracket interface; (b) gingival bracket-adhesive interface; (c) occlusal adhesive-enamel interface; (d) gingival adhesive-enamel interface

Means adhesive interface scores according to each adhesive. (a) occlusal bracket interface; (b) gingival bracket-adhesive interface; (c) occlusal adhesive-enamel interface; (d) gingival adhesive-enamel interface

DISCUSSION

The goal of this study was to determine whether the type of adhesive material used to bond brackets might play a role in the stability of the bracket-adhesive bonds. If the stability or “tightness” of a bonding material is compromised, the resulting outcome is microleakage. From an orthodontic perspective, microleakage could very well lead to the formation of white-spot lesions at the “adhesive-enamel” interface.[910] These lesions are characterized by enamel decalcification, a known consequence of bacterial plaque's remaining on the enamel surface for a long period of time. Teeth are daily exposed to temperature variations, due to the ingestion of food and hot and cold drinks and so would be adhesives on teeth. Thus, thermal expansion coefficient of the adhesive must be close to that of dental tissue; otherwise, the tooth and the material will contract and expand at different rates. These repeated movements at different values could cause influx of bacteria-rich fluids of the oral cavity into the spaces formed between the tooth and the filling material. this is known as percolation phenomenon. Adhesive materials shrink differently while polymerizing. This shrinking factor differs depending on the composition of the adhesive.[1] Transbond Plus Self-Etching, (Group 2), used in this study is a self-etching system. The advantage of this sort of systems is that it reduces the number of steps involved in cementing, thereby reducing procedure time. The etching process is simplified because the etching acid and primer are applied to the dental tissue in one step.[12] The “Transbond Plus Self-Etching” system contains phosphoric acid methacrylate, which serves as etching acid and primer. The depth of the demineralized area in the enamel will be the penetration area of the adhesive. Uysal et al. reported that brackets bonded using a self-etching system returned higher microleakage scores than brackets bonded using conventional total etching systems.[1] Their results are consistent with those obtained in our study. As observed in other studies, the gingival margin of the bracket showed a degree of microleakage. However, the occlusal margin of the bracket-adhesive interface showed more microleakage; this was not so in several other studies. Dye penetration was used for assessing microleakage. It is the easiest and most widely used technique. it is quick, directly measures microleakage, does not react with the hard tissues, is nontoxic, and is cost-effective.[4] The thermal cycling technique have been extensively used in this type of studies.[811] Thermal expansion is a factor that affects adhesion between the adhesive material and the tooth. The difference in expansion coefficients within the “bracket-adhesive-enamel” complex results in different dimensional changes during temperature variations that may produce fractures, cracks resulting in microleakage.[7] According to the results obtained in our study, the occlusal margin was prone to microleakage at each of the interfaces and with all of the cementing systems, but this difference was not statistically significant. Unlike other studies, the difference in microleakage at the occlusal margin of the “bracket-adhesive” interface was significant. In a previous study, microleakage scores were higher in the gingival margin of the brackets. Their interpretation of the results was that the differences in scores between the occlusal and gingival margins were due to the tooth morphology, which results in a narrower interface with the adhesive on the gingival side.[7] However, no indication was given of whether the study used maxillary or mandibular premolars. Further, they compared a total etching bonding system against an antibacterial self-etching bonding system on ceramic and metallic brackets.[7] The same results were also obtained by the work of Uysal et al. that compared two adhesive systems on ceramic and metallic brackets. However, they hypothesized that the low microleakage scores at the occlusal margin were due to the adhesive curing method, as they applied the curing light occlusally for 40 s.[1] Looking at our results, the significant difference in the “occlusal bracket-adhesive” variable may be due to the fact that we applied the curing light on the mesial and distal sides for 20 s each time. Microleakage scores were observed with all the cementing systems. The [Figure 5] shows the comparison between the mean values at the occlusal and gingival interface for each adhesive brands.
Figure 5

Mean scores of the different adhesive brands at each occlusal and gingival interface

Mean scores of the different adhesive brands at each occlusal and gingival interface Microleakage was present in all groups. We observed a significant difference in the “occlusal bracket adhesive” group. In the “gingival bracket adhesive,” “occlusal adhesive enamel,” and “gingival adhesive enamel” groups, there was no significant difference. The adhesive that returned the lowest microleakage score was Group 6, “Transbond MIP;” conversely, Group 2, “Transbond Plus Self-Etching,” returned the highest microleakage scores. Group 2 was a self-etching system whereas Group 6 was a conventional etching system. We can conclude that enamel bonding using conventional etching results in greater, better-quality adhesion.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.
  13 in total

1.  Depth of resin penetration into enamel with 3 types of enamel conditioning methods: a confocal microscopic study.

Authors:  K R Ramesh Kumar; K K Shanta Sundari; A Venkatesan; Shymalaa Chandrasekar
Journal:  Am J Orthod Dentofacial Orthop       Date:  2011-10       Impact factor: 2.650

2.  Scanning electron microscopy evaluation of the bonding mechanism of a self-etching primer on enamel.

Authors:  Julio P Cal-Neto; José Augusto M Miguel
Journal:  Angle Orthod       Date:  2006-01       Impact factor: 2.079

3.  Bond strength comparison and scanning electron microscopic evaluation of three orthodontic bonding systems.

Authors:  Masahiro Iijima; Shuichi Ito; Toshihiro Yuasa; Takeshi Muguruma; Takashi Saito; Itaru Mizoguchi
Journal:  Dent Mater J       Date:  2008-05       Impact factor: 2.102

4.  Microleakage under orthodontic brackets bonded with the custom base indirect bonding technique.

Authors:  Ahmet Yagci; Tancan Uysal; Mustafa Ulker; Sabri Ilhan Ramoglu
Journal:  Eur J Orthod       Date:  2009-09-13       Impact factor: 3.075

5.  Microleakage in relation to amalgam and composite restorations. A laboratory study.

Authors:  E A Kidd
Journal:  Br Dent J       Date:  1976-11-16       Impact factor: 1.626

Review 6.  State of the art etch-and-rinse adhesives.

Authors:  David H Pashley; Franklin R Tay; Lorenzo Breschi; Leo Tjäderhane; Ricardo M Carvalho; Marcela Carrilho; Arzu Tezvergil-Mutluay
Journal:  Dent Mater       Date:  2010-11-27       Impact factor: 5.304

7.  Microleakage beneath ceramic and metal brackets bonded with a conventional and an antibacterial adhesive system.

Authors:  Neslihan Arhun; Ayca Arman; Sevi Burçak Cehreli; Serdar Arikan; Erdem Karabulut; Kamran Gülşahi
Journal:  Angle Orthod       Date:  2006-11       Impact factor: 2.079

8.  Evaluation of bovine and human teeth exposed to thermocycling for microleakage under bonded metal brackets.

Authors:  Kerem Canbek; Mareike Karbach; Franziska Gottschalk; Christina Erbe; Heinrich Wehrbein
Journal:  J Orofac Orthop       Date:  2013-03-07       Impact factor: 1.938

9.  Are the low-shrinking composites suitable for orthodontic bracket bonding?

Authors:  Suleyman Kutalmis Buyuk; Kenan Cantekin; Sezer Demirbuga; Mehmet Ali Ozturk
Journal:  Eur J Dent       Date:  2013-07

10.  Microleakage under orthodontic brackets bonded with different adhesive systems.

Authors:  Huseyin Alkis; Hakan Turkkahraman; Necdet Adanir
Journal:  Eur J Dent       Date:  2015 Jan-Mar
View more
  2 in total

1.  Evaluation of microleakage for three types of light cure orthodontic band cement.

Authors:  Lara Riyadh Al-Banaa
Journal:  J Oral Biol Craniofac Res       Date:  2022-04-19

2.  A Novel Evaluation Method for Detecting Defects of the Bonded Orthodontic Bracket-Tooth Interface.

Authors:  Mona Aly Abbassy; Turki A Bakhsh; Ahmed Samir Bakry
Journal:  Biomed Res Int       Date:  2021-03-15       Impact factor: 3.411

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.