Literature DB >> 28729473

Automatic versus manual oxygen administration in the emergency department.

Erwan L'Her1,2,3,4, Patricia Dias5, Maelenn Gouillou5, Anne Riou6, Luc Souquiere6, Nicolas Paleiron6, Patrick Archambault7, Pierre-Alexandre Bouchard8, François Lellouche4,8.   

Abstract

Oxygen is commonly administered in hospitals, with poor adherence to treatment recommendations.We conducted a multicentre randomised controlled study in patients admitted to the emergency department requiring O2 ≥3 L·min-1 Patients were randomised to automated closed-loop or manual O2 titration during 3 h. Patients were stratified according to arterial carbon dioxide tension (PaCO2 ) (hypoxaemic PaCO2 ≤45 mmHg; or hypercapnic PaCO2 >45-≤55 mmHg) and study centre. Arterial oxygen saturation measured by pulse oximetry (SpO2 ) goals were 92-96% for hypoxaemic, or 88-92% for hypercapnic patients. Primary outcome was % time within SpO2 target. Secondary endpoints were hypoxaemia and hyperoxia prevalence, O2 weaning, O2 duration and hospital length of stay.187 patients were randomised (93 automated, 94 manual) and baseline characteristics were similar between the groups. Time within the SpO2 target was higher under automated titration (81±21% versus 51±30%, p<0.001). Time with hypoxaemia (3±9% versus 5±12%, p=0.04) and hyperoxia under O2 (4±9% versus 22±30%, p<0.001) were lower with automated titration. O2 could be weaned at the end of the study in 14.1% versus 4.3% patients in the automated and manual titration group, respectively (p<0.001). O2 duration during the hospital stay was significantly reduced (5.6±5.4 versus 7.1±6.3 days, p=0.002).Automated O2 titration in the emergency department improved oxygenation parameters and adherence to guidelines, with potential clinical benefits.
Copyright ©ERS 2017.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28729473     DOI: 10.1183/13993003.02552-2016

Source DB:  PubMed          Journal:  Eur Respir J        ISSN: 0903-1936            Impact factor:   16.671


  11 in total

1.  O2 saturation target of 96-100% should be abandoned.

Authors:  Jens Gottlieb; Anna Bertram; Christoph Duesberg; Gernot Beutel
Journal:  Dtsch Arztebl Int       Date:  2018-10-12       Impact factor: 5.594

2.  Use and misuse of oxygen administration.

Authors:  G A Marraro; C Spada
Journal:  J Postgrad Med       Date:  2020 Jul-Sep       Impact factor: 1.476

3.  Oxygen therapy in the pre-hospital setting for acute exacerbations of chronic obstructive pulmonary disease.

Authors:  Zoe Kopsaftis; Kristin V Carson-Chahhoud; Michael A Austin; Richard Wood-Baker
Journal:  Cochrane Database Syst Rev       Date:  2020-01-14

4.  Closed-loop oxygen control improves oxygen therapy in acute hypoxemic respiratory failure patients under high flow nasal oxygen: a randomized cross-over study (the HILOOP study).

Authors:  Oriol Roca; Oriol Caritg; Manel Santafé; Francisco J Ramos; Andrés Pacheco; Marina García-de-Acilu; Ricard Ferrer; Marcus J Schultz; Jean-Damien Ricard
Journal:  Crit Care       Date:  2022-04-14       Impact factor: 9.097

5.  COVID-19: Pulse oximeters in the spotlight.

Authors:  Frederic Michard; Kirk Shelley; Erwan L'Her
Journal:  J Clin Monit Comput       Date:  2020-06-23       Impact factor: 2.502

6.  Automated oxygen administration versus conventional oxygen therapy after major abdominal or thoracic surgery: study protocol for an international multicentre randomised controlled study.

Authors:  Erwan L'her; Samir Jaber; Daniel Verzilli; Christophe Jacob; Brigitte Huiban; Emmanuel Futier; Thomas Kerforne; Victoire Pateau; Pierre-Alexandre Bouchard; Maellen Gouillou; Emmanuel Nowak; François Lellouche
Journal:  BMJ Open       Date:  2019-01-17       Impact factor: 2.692

7.  Automated oxygen control with O2matic® during admission with exacerbation of COPD.

Authors:  Ejvind Frausing Hansen; Jens Dahlgaard Hove; Charlotte Sandau Bech; Jens-Ulrik Stæhr Jensen; Thomas Kallemose; Jørgen Vestbo
Journal:  Int J Chron Obstruct Pulmon Dis       Date:  2018-12-14

8.  Automated Oxygen Delivery in Hospitalized Patients with Acute Respiratory Failure: A Pilot Study.

Authors:  Foteini Malli; Stelios Boutlas; Nick Lioufas; Konstantinos I Gourgoulianis
Journal:  Can Respir J       Date:  2019-02-03       Impact factor: 2.409

9.  Determination of oxygen saturation compared to a prescribed target range using continuous pulse oximetry in acutely unwell medical patients.

Authors:  James C P Harper; Ruth Semprini; Nethmi A Kearns; Lee Hatter; Grace E Bird; Irene Braithwaite; Allie Eathorne; Mark Weatherall; Richard Beasley
Journal:  BMC Pulm Med       Date:  2021-10-26       Impact factor: 3.317

10.  Automatic oxygen titration with O2matic® to patients admitted with COVID-19 and hypoxemic respiratory failure.

Authors:  Ejvind Frausing Hansen; Charlotte Sandau Bech; Jørgen Vestbo; Ove Andersen; Linette Marie Kofod
Journal:  Eur Clin Respir J       Date:  2020-10-14
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.