Literature DB >> 28718772

Performance evaluation of MACACO: a multilayer Compton camera.

Enrique Muñoz1, John Barrio, Ane Etxebeste, Pablo G Ortega, Carlos Lacasta, Josep F Oliver, Carles Solaz, Gabriela Llosá.   

Abstract

Compton imaging devices have been proposed and studied for a wide range of applications. We have developed a Compton camera prototype which can be operated with two or three detector layers based on monolithic lanthanum bromide ([Formula: see text]) crystals coupled to silicon photomultipliers (SiPMs), to be used for proton range verification in hadron therapy. In this work, we present the results obtained with our prototype in laboratory tests with radioactive sources and in simulation studies. Images of a [Formula: see text]Na and an [Formula: see text]Y radioactive sources have been successfully reconstructed. The full width half maximum of the reconstructed images is below 4 mm for a [Formula: see text]Na source at a distance of 5 cm.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28718772     DOI: 10.1088/1361-6560/aa8070

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  6 in total

1.  Roadmap toward the 10 ps time-of-flight PET challenge.

Authors:  Paul Lecoq; Christian Morel; John O Prior; Dimitris Visvikis; Stefan Gundacker; Etiennette Auffray; Peter Križan; Rosana Martinez Turtos; Dominique Thers; Edoardo Charbon; Joao Varela; Christophe de La Taille; Angelo Rivetti; Dominique Breton; Jean-François Pratte; Johan Nuyts; Suleman Surti; Stefaan Vandenberghe; Paul Marsden; Katia Parodi; Jose Maria Benlloch; Mathieu Benoit
Journal:  Phys Med Biol       Date:  2020-10-22       Impact factor: 3.609

Review 2.  Compton imaging for medical applications.

Authors:  Hideaki Tashima; Taiga Yamaya
Journal:  Radiol Phys Technol       Date:  2022-07-22

3.  3D prompt gamma imaging for proton beam range verification.

Authors:  E Draeger; D Mackin; S Peterson; H Chen; S Avery; S Beddar; J C Polf
Journal:  Phys Med Biol       Date:  2018-01-30       Impact factor: 3.609

4.  Prompt gamma imaging for the identification of regional proton range deviations due to anatomic change in a heterogeneous region.

Authors:  Yunhe Xie; Johannes Petzoldt; Guillaume Janssens; Fionnbarr O'Grady; Lingshu Yin; El Hassane Bentefour; Julien Smeets; Damien Prieels; Robert A Lustig; Alexander Lin; Boon-Keng Teo
Journal:  Br J Radiol       Date:  2020-10-06       Impact factor: 3.039

5.  Electron-tracking Compton camera imaging of technetium-95m.

Authors:  Yuichi Hatsukawa; Takehito Hayakawa; Kazuaki Tsukada; Kazuyuki Hashimoto; Tetsuya Sato; Masato Asai; Atsushi Toyoshima; Toru Tanimori; Shinya Sonoda; Shigeto Kabuki; Hiroyuki Kimura; Atsushi Takada; Tetsuya Mizumoto; Seiya Takaki
Journal:  PLoS One       Date:  2018-12-10       Impact factor: 3.240

6.  Proton range verification with MACACO II Compton camera enhanced by a neural network for event selection.

Authors:  Enrique Muñoz; Ana Ros; Marina Borja-Lloret; John Barrio; Peter Dendooven; Josep F Oliver; Ikechi Ozoemelam; Jorge Roser; Gabriela Llosá
Journal:  Sci Rep       Date:  2021-04-29       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.