| Literature DB >> 28713460 |
Randy L Aldret1, Brittany A Trahan1, Greggory Davis1, Brian Campbell1, David M Bellar1.
Abstract
The purpose of this study was to determine the appropriateness of using an elastic hamstring assistance device to reduce perceived levels of soreness, increase isometric strength, increase passive range of motion, and decrease biomarkers of muscle damage after eccentric exercise, specifically, downhill running This study was conducted in a university exercise physiology laboratory placing sixteen apparently healthy males (X = 21.6 ± 2.5 years) into two groups using a pre-test/post-test design. Pre-intervention measures taken included participants' body height, body mass, body fat, capillary blood samples, VO2max, isometric hamstring strength at 45 and 90 degrees of flexion and passive hamstring range of motion. Post-intervention measures included blood biomarkers, passive range of motion, the perceived level of soreness and isometric strength. An analysis of normality of data was initially conducted followed by multivariate analysis of variance (MANOVA) of hamstring strength at 45 and 90 degrees of flexion, blood myoglobin and passive range of motion of the hamstrings. Statistically significant changes were noted in subject-perceived muscle soreness and isometric strength at 90 degrees at the 24-hour post-exercise trial measure between the two groups. Results would suggest the findings could be explained by the decrease in muscle soreness from utilizing the device during the exercise trial. Further research should be conducted to address sample size issues and to determine if the results are comparable on different surfaces.Entities:
Keywords: hamstring; isometrics; myoglobin; soreness
Year: 2017 PMID: 28713460 PMCID: PMC5504580 DOI: 10.1515/hukin-2017-0048
Source DB: PubMed Journal: J Hum Kinet ISSN: 1640-5544 Impact factor: 2.193
Participants’ Characteristics
| Group | N | Age (years) | Body | Body Mass | Body Fat % | VO2max | Running |
|---|---|---|---|---|---|---|---|
| Height (m) | (kg) | (ml/kg/min) | Speed (km/h) | ||||
| Device | 8 | 20.25 ± 1.75 | 1.78 ± .07 | 74.84 ± 8.53 | 13.13 ± 6.66 | 50.61 ± 3.95 | 10.59 ± .90 |
| Non-Device | 8 | 23.00 ± 2.45 | 1.76 ± .08 | 82.65 ± 10.96 | 18.36 ± 6.23 | 46.19 ± 6.14 | 9.61 ± 1.40 |
Passive Hamstring Range of Motion
| Group | n | Initial Hamstring ROM (° of hip flexion measured supine) | 1hr Post Hamstring ROM (° of hip flexion measured supine) | 12hr Post Hamstring ROM (° of hip flexion measured supine) | 24hr Post Hamstring ROM (° of hip flexion measured supine) |
|---|---|---|---|---|---|
| Right Leg | |||||
| Device | 8 | 72.75° ± 17.12° | 74.17° ± 12.91° | 79.42° ± 5.82° | 75.54° ± 17.07° |
| Non-Device | 8 | 75.96° ± 10.11° | 74.88° ± 9.59° | 79.33° ± 9.23° | 76.54° ± 12.36° |
| Left Leg | |||||
| Device | 8 | 73.79° ± 15.11° | 72.08° ± 15.92° | 80.25° ± 8.72° | 78.38° ± 9.43° |
| Non-Device | 8 | 74.29° ± 13.19° | 70.21°± 10.28° | 74.71° ± 7.45° | 72.67° ± 14.14° |
Isometric Hamstring Strength at 45° of Knee Flexion
| Group | n | Initial Isometric Strength (N) | 1hr Post Isometric Strength (N) | 12hr Post Isometric Strength (N) | 24hr Post Isometric Strength (N) |
|---|---|---|---|---|---|
| Right Leg | |||||
| Device | 8 | 377.68 ± 100.30 | 373.61 ± 96.46 | 405.67 ± 155.64 | 382.09 ± 160.84 |
| Non-Device | 8 | 380.98 ± 131.34 | 391.33 ± 179.59 | 335.18 ± 130.11 | 405.14 ± 135.89 |
| Left Leg | |||||
| Device | 8 | 368.07 ± 117.36 | 424.23 ± 151.83 | 421.12 ± 114.12 | 390.98 ± 120.70 |
| Non-Device | 8 | 426.02 ± 162.50 | 446.27 ± 163.24 | 414.11 ± 174.02 | 422.65 ± 159.89 |
Isometric Hamstring Strength at 90° of Knee Flexion
| Group | n | Initial Isometric Strength (N) | 1hr Post Isometric Strength (N) | 12hr Post Isometric Strength (N) | 24hr Post Isometric Strength (N) |
|---|---|---|---|---|---|
| Right Leg | |||||
| Device | 8 | 254.40 ± 108.55 | 296.49 ± 118.56 | 347.75 ± 136.86 | 330.98 ± 107.97 |
| Non-Device | 8 | 333.56 ± 103.43 | 375.96 ± 83.11 | 350.26 ± 100.82 | 332.64 ± 101.66 |
| Left Leg | |||||
| Device | 8 | 264.53 ± 121.30 | 303.64 ± 125.18 | 335.49 ± 121.59 | 316.43 ± 129.57 |
| Non-Device | 8 | 357.95 ± 121.11 | 381.70 ± 107.44 | 308.57 ± 127.50 | 339.20 ± 121.90 |
significant at p ≥ .05
Subjective Measure of Hamstring Muscle Soreness
| Group | n | Soreness Scale (1 = no soreness; 10 = worst pain ever experienced) |
|---|---|---|
| Device | 8 | 1.25 ± .71 |
| Non-Device | 8 | 4.63 ± 2.26 |
significant at p ≥.05
significant at p ≥.01
Blood Myoglobin concentration
| Device | 8 | 7.47 ± 6.29 | 29.80 ± 11.77 | 17.23 ± 10.74 | 15.22 ± 8.72 |