Literature DB >> 28709931

Non-invasive vibrometry-based diagnostic detection of acetabular cup loosening in total hip replacement (THR).

Abdullah A Alshuhri1, Timothy P Holsgrove2, Anthony W Miles3, James L Cunningham4.   

Abstract

Total hip replacement is aimed at relieving pain and restoring function. Currently, imaging techniques are primarily used as a clinical diagnosis and follow-up method. However, these are unreliable for detecting early loosening, and this has led to the proposal of novel techniques such as vibrometry. The present study had two aims, namely, the validation of the outcomes of a previous work related to loosening detection, and the provision of a more realistic anatomical representation of the clinical scenario. The acetabular cup loosening conditions (secure, and 1 and 2 mm spherical loosening) considered were simulated using Sawbones composite bones. The excitation signal was introduced in the femoral lateral condyle region using a frequency range of 100-1500 Hz. Both the 1 and 2 mm spherical loosening conditions were successfully distinguished from the secure condition, with a favourable frequency range of 500-1500 Hz. The results of this study represent a key advance on previous research into vibrometric detection of acetabular loosening using geometrically realistic model, and demonstrate the clinical potential of this technique. Crown
Copyright © 2017. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Acetabular cup loosening; Loosening diagnosis; Non-invasive diagnosis; Vibration analysis

Mesh:

Year:  2017        PMID: 28709931     DOI: 10.1016/j.medengphy.2017.06.037

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  4 in total

1.  Ex Vivo Evaluation of Cementless Acetabular Cup Stability Using Impact Analyses with a Hammer Instrumented with Strain Sensors.

Authors:  Antoine Tijou; Giuseppe Rosi; Philippe Hernigou; Charles-Henri Flouzat-Lachaniette; Guillaume Haïat
Journal:  Sensors (Basel)       Date:  2017-12-27       Impact factor: 3.576

2.  Relationship between use of screws and acetabular cup stability in total hip arthroplasty: a meta-analysis.

Authors:  Chen Fei; Peng-Fei Wang; Wei Wei; Shuang-Wei Qu; Kun Yang; Zhi Li; Yan Zhuang; Bin-Fei Zhang; Kun Zhang
Journal:  J Int Med Res       Date:  2020-02       Impact factor: 1.671

Review 3.  Altering the Course of Technologies to Monitor Loosening States of Endoprosthetic Implants.

Authors:  João Henrique Cachão; Marco P Soares Dos Santos; Rodrigo Bernardo; António Ramos; Rainer Bader; Jorge A F Ferreira; António Torres Marques; José A O Simões
Journal:  Sensors (Basel)       Date:  2019-12-23       Impact factor: 3.576

4.  Multiscale Sensing of Bone-Implant Loosening for Multifunctional Smart Bone Implants: Using Capacitive Technologies for Precision Controllability.

Authors:  Inês Peres; Pedro Rolo; Jorge A F Ferreira; Susana C Pinto; Paula A A P Marques; António Ramos; Marco P Soares Dos Santos
Journal:  Sensors (Basel)       Date:  2022-03-25       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.