Literature DB >> 28708924

Bone and Soft Tissue Response in Bone-Level Implants Restored with Platform Switching: A 5-Year Clinical Prospective Study.

Laura Lago, Luis da Silva, Francisco Gude, Benito Rilo.   

Abstract

PURPOSE: The aim of this prospective study was to evaluate radiographic levels of peri-implant bone crest as well as soft tissue response, papilla height, and buccal mucosa recession, in bone-level implants restored with platform switching after 1-year and 5-year follow-ups.
MATERIALS AND METHODS: This prospective study called for the placement of 59 implants to obtain a target of 90% power. To compensate for possible dropouts, the sample size was adjusted to 67 implants. To assess marginal bone level changes, periapical radiographs were taken at baseline, 1 year, and 5 years after the definitive restorations. Peri-implant soft tissue modifications were evaluated by performing a photographic sequence at 15 days, 1 year, and 5 years after implant restoration. Parameters measured were: (1) distance from the tip of the papilla to the contact point and (2) apicocoronal crown length.
RESULTS: A one-way analysis of variance (ANOVA rank test) was used to compare quantitative data among the three time points studied. Mean marginal bone level changes were as follows: -0.06 ± 0.32 mm from baseline to 1 year, -0.23 ± 0.38 mm from 1 to 5 years, and -0.28 ± 0.45 mm from baseline to 5 years. In bone-level outcomes, no statistically significant differences were found between baseline and 1 year, while the mean differences between 1 and 5 years and baseline and 5 years showed statistically significant differences. In the soft tissue analysis, the distance from the tip of the papilla to the contact point showed the following values: baseline, 2.08 mm; 1 year, 1.54 mm; 5 years, 1.31 mm. No statistically significant differences were found between baseline and 1 year, whereas statistically significant differences between 1 and 5 years and baseline and 5 years were found. Apicocoronal crown length measurements showed the following values: baseline, 9.44 mm; 1 year, 9.28 mm; 5 years, 9.81 mm. No significant differences were found between times studied.
CONCLUSION: This prospective clinical study of 67 bone-level implants restored according to the platform-switching concept reported that radiographic levels of peri-implant bone crest were statistically significant between 1 and 5 years and baseline and 5 years. For the soft tissue response, the greatest reduction in the distance from the papilla to the contact point from 1 to 5 years and baseline to 5 years was observed. No significant differences were shown in the buccal margin.

Entities:  

Mesh:

Year:  2017        PMID: 28708924     DOI: 10.11607/jomi.5859

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  4 in total

1.  Comparative Evaluation of Marginal Bone Loss and Implant Failure Rate in Smokers and Nonsmokers.

Authors:  Abhishek Kumar; Saba Nasreen; Subhash Bandgar; Devleena Bhowmick; Ritesh Vatsa; Priyanka Priyadarshni
Journal:  J Pharm Bioallied Sci       Date:  2021-06-05

2.  Peri-Implant Marginal Bone Changes around Dental Implants with Platform-Switched and Platform-Matched Abutments: A Retrospective 5-Year Radiographic Evaluation.

Authors:  Hsi-Kuei Lin; Jerry Chin-Yi Lin; Yu-Hwa Pan; Eisner Salamanca; Yi-Ting Chang; Yung-Szu Hsu; Yi-Fan Wu; Chin-Kai Lin; Odontuya Dorj; Wei-Jen Chang
Journal:  J Pers Med       Date:  2022-07-27

Review 3.  Bone loss-related factors in tissue and bone level dental implants: a systematic review of clinical trials.

Authors:  Hamed Mortazavi; Amin Khodadoustan; Aida Kheiri; Lida Kheiri
Journal:  J Korean Assoc Oral Maxillofac Surg       Date:  2021-06-30

4.  Influence of the implant-abutment connection on the ratio between height and thickness of tissues at the buccal zenith: a randomized controlled trial on 188 implants placed in 104 patients.

Authors:  Davide Farronato; Pietro Mario Pasini; Mattia Manfredini; Cristian Scognamiglio; Andrea Alain Orsina; Marco Farronato
Journal:  BMC Oral Health       Date:  2020-02-17       Impact factor: 2.757

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.