Literature DB >> 28708918

The Influence of Low Insertion Torque on Primary Stability, Implant Survival, and Maintenance of Marginal Bone Levels: A Closed-Cohort Prospective Study.

Michael R Norton.   

Abstract

PURPOSE: The purpose of this study was to evaluate the impact of low insertion torque on primary stability and the short-term clinical outcome of single-tooth implants placed into healed ridges and fresh extraction sockets.
MATERIALS AND METHODS: A cohort of n = 30 implants was self-selected on the basis that their insertion torque measured ≤ 20 Ncm. The cohort was closed with the follow-up set at 1 year. Resonance frequency analysis was evaluated in both mesiodistal (MD) and buccolingual (BL) directions at the time of implant insertion and at the time of restoration. Immediate temporization was determined by the esthetic need and a minimum implant stability quotient (ISQ) reading of 55. Implants were definitively restored after approximately 3 months. Implant survival was recorded along with changes in the level of the marginal bone relative to a fixed reference point, at the 1-year follow-up.
RESULTS: Twenty-two patients with a total of 30 implants were grouped by insertion torques of < 5 Ncm (spinners), > 5 < 10 Ncm, 10 Ncm, 15 Ncm, and 20 Ncm. One implant was excluded because follow-up data were unavailable. Of the remaining 29 implants, the mean ISQ measured 67 (MD) and 65 (BL) at surgery. The values increased to 80 (MD) and 79 (BL) after a period of 3 months. The survival rate at the end of the 1-year period was 96.7%, including the excluded implant, but 100% for the remaining 29 implants. The frequency of implants demonstrating no marginal bone loss was 71.4%, 0.1 to 0.5 mm bone loss was 21.4%, and bone loss > 0.5 mm (max = 2.82 mm) was only 7.2%. No implants were lost during the functional loading period. Data on immediate temporization revealed no significant difference in ISQ or marginal bone loss values for implants in this group.
CONCLUSION: Lower insertion torques yield favorable survival rates with optimal marginal bone levels compared with the accepted norm.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28708918     DOI: 10.11607/jomi.5889

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  8 in total

1.  [Immediate implantation following tooth extraction in fresh maxillary molar socket with poor bone quality].

Authors:  Jing Xu
Journal:  Nan Fang Yi Ke Da Xue Xue Bao       Date:  2019-01-30

2.  Effects of osseodensification protocol on insertion, removal torques, and resonance frequency analysis of BioHorizons® conical implants. An ex vivo study.

Authors:  Felipe Cáceres; Cristian Troncoso; Ramón Silva; Nelson Pinto
Journal:  J Oral Biol Craniofac Res       Date:  2020-08-31

3.  In vitro evaluation of the influence of bone cortical thickness on the primary stability of conventional- and short-sized implants.

Authors:  Luiz-Antônio-Borelli Barros; Caio-Fossalussa da Silva; Germana-de Villa Camargos; Elcio Marcantonio; Guilherme-José-Pimentel-Lopes de Oliveira; Luiz-Antônio-Borelli Barros-Filho
Journal:  J Clin Exp Dent       Date:  2022-02-01

4.  The Importance of Correlation between CBCT Analysis of Bone Density and Primary Stability When Choosing the Design of Dental Implants-Ex Vivo Study.

Authors:  Mirko Mikic; Zoran Vlahovic; Momir Stevanović; Zoran Arsic; Rasa Mladenovic
Journal:  Tomography       Date:  2022-05-11

5.  Influence of Insertion Torque on Clinical and Biological Outcomes before and after Loading of Mandibular Implant-Retained Overdentures in Atrophic Edentulous Mandibles.

Authors:  Fernanda Faot; Amália Machado Bielemann; Alessandra Julie Schuster; Raissa Micaella Marcello-Machado; Altair Antoninha Del Bel Cury; Gustavo G Nascimento; Otacílio Luiz Chagas-Junior
Journal:  Biomed Res Int       Date:  2019-06-02       Impact factor: 3.411

6.  Effects of insertion torque values on the marginal bone loss of dental implants installed in sheep mandibles.

Authors:  Sergio Alexandre Gehrke; Jaime Aramburú Júnior; Tiago Luis Eirles Treichel; Tales Dias do Prado; Berenice Anina Dedavid; Piedad N de Aza
Journal:  Sci Rep       Date:  2022-01-11       Impact factor: 4.996

7.  Correlation between Insertion Torque and Implant Stability Quotient in Tapered Implants with Knife-Edge Thread Design.

Authors:  Domenico Baldi; Teresa Lombardi; Jacopo Colombo; Gabriele Cervino; Giuseppe Perinetti; Roberto Di Lenarda; Claudio Stacchi
Journal:  Biomed Res Int       Date:  2018-05-15       Impact factor: 3.411

Review 8.  Dental Implants Inserted in Fresh Extraction Sockets versus Healed Sites: A Systematic Review and Meta-Analysis.

Authors:  Adam Ibrahim; Bruno Ramos Chrcanovic
Journal:  Materials (Basel)       Date:  2021-12-20       Impact factor: 3.623

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.