Clinical Performance of Dental Implants with a Moderately Rough (TiUnite) Surface: A Meta-Analysis of Prospective Clinical Studies.

Matthias Karl, Tomas Albrektsson.   

Abstract

PURPOSE: A moderately rough anodized titanium implant surface (TiUnite) was introduced in 2000. This review and meta-analysis aimed to assess implant survival and marginal bone level (MBL) changes documented in the literature.
MATERIALS AND METHODS: Repeated literature searches on dental implants were conducted, with the final search on October 7, 2016. The inclusion criteria were: prospective study, minimum of 20 patients, at least 12 months follow-up postloading, and TiUnite implant survival reported. Regression analysis was performed on implant survival and MBL change from implant surgery. Peri-implantitis as defined by the primary authors was reported at the patient level.
RESULTS: One hundred six out of 32,519 publications on dental implants met the inclusion criteria. Implant survival rates at 1 year were 99.50% at the implant level and 99.12% at the patient level, and survival rates at 10 years were 95.14% at the implant level and 91.50% at the patient level. Mean MBL change at 1 year was -0.409 mm at the implant level and -0.413 mm at the patient level, and at 5 years, it was -0.886 mm at the implant level and -1.029 mm at the patient level. Nineteen studies (18%) specifically reported peri-implantitis in 64 out of 1,229 patients with a mean follow-up of 47.89 months, indicating a prevalence of 5.20% at the patient level.
CONCLUSION: Based on a meta-analysis of prospective studies, implants with the TiUnite surface provide a predictable treatment modality in a variety of indications.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28708905     DOI: 10.11607/jomi.5699

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  6 in total

1.  An Osteotomy Tool That Preserves Bone Viability: Evaluation in Preclinical and Clinical Settings.

Authors:  Oded Bahat; Xing Yin; Stefan Holst; Ion Zabalegui; Eva Berroeta; Javier Pérez; Peter Wöhrle; Norbert Sörgel; John Brunski; Jill A Helms
Journal:  J Clin Med       Date:  2022-04-30       Impact factor: 4.964

2.  Intraosseous Temperature Change during Installation of Dental Implants with Two Different Surfaces and Different Drilling Protocols: An In Vivo Study in Sheep.

Authors:  Michele Stocchero; Yohei Jinno; Marco Toia; Marianne Ahmad; Evaggelia Papia; Satoshi Yamaguchi; Jonas P Becktor
Journal:  J Clin Med       Date:  2019-08-11       Impact factor: 4.241

3.  On the Cleanliness of Different Oral Implant Systems: A Pilot Study.

Authors:  Dirk U Duddeck; Tomas Albrektsson; Ann Wennerberg; Christel Larsson; Florian Beuer
Journal:  J Clin Med       Date:  2019-08-22       Impact factor: 4.241

4.  A Clinical and Radiographic Evaluation of Zirconia Dental Implants: 10-Year Follow-Up.

Authors:  Andrea Enrico Borgonovo; Susanna Ferrario; Carlo Maiorana; Virna Vavassori; Rachele Censi; Dino Re
Journal:  Int J Dent       Date:  2021-12-30

Review 5.  Innovative Concepts and Recent Breakthrough for Engineered Graft and Constructs for Bone Regeneration: A Literature Systematic Review.

Authors:  Francesco Inchingolo; Denisa Hazballa; Alessio Danilo Inchingolo; Giuseppina Malcangi; Grazia Marinelli; Antonio Mancini; Maria Elena Maggiore; Ioana Roxana Bordea; Antonio Scarano; Marco Farronato; Gianluca Martino Tartaglia; Felice Lorusso; Angelo Michele Inchingolo; Gianna Dipalma
Journal:  Materials (Basel)       Date:  2022-01-31       Impact factor: 3.623

6.  Sandblasting reduces dental implant failure rate but not marginal bone level loss: A systematic review and meta-analysis.

Authors:  László Márk Czumbel; Beáta Kerémi; Noémi Gede; Alexandra Mikó; Barbara Tóth; Dezső Csupor; Andrea Szabó; Sándor Farkasdi; Gábor Gerber; Márta Balaskó; Erika Pétervári; Róbert Sepp; Péter Hegyi; Gábor Varga
Journal:  PLoS One       Date:  2019-05-03       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.