Literature DB >> 28706000

Absence of compensatory vasodilation with perfusion pressure challenge in exercise: evidence for and implications of the noncompensator phenotype.

Robert F Bentley1, Jeremy J Walsh1, Patrick J Drouin1, Aleksandra Velickovic1, Sarah J Kitner1, Alyssa M Fenuta1, Michael E Tschakovsky1.   

Abstract

Compromising oxygen delivery (O2D) during exercise requires compensatory vasodilatory and/or pressor responses to protect O2D:demand matching. The purpose of the study was to determine whether compensatory vasodilation is absent in some healthy young individuals in the face of a sudden reduction in exercising forearm perfusion pressure and whether this affects the exercise pressor response. Twenty-one healthy young men (21.6 ± 2.0 yr) completed rhythmic forearm exercise at a work rate equivalent to 70% of their own maximal exercise vasodilation. During steady-state exercise, the exercising arm was rapidly adjusted from below to above heart level, resulting in a reduction in forearm perfusion pressure of -30.7 ± 0.9 mmHg. Forearm blood flow (ml/min; brachial artery Doppler and echo ultrasound), mean arterial blood pressure (mmHg; finger photoplethysmography), and exercising forearm venous effluent (antecubital vein catheter) measurements revealed distinct compensatory vasodilatory differences. Thirteen individuals responded with compensatory vasodilation (509 ± 128 vs. 632 ± 136 ml·min-1·100 mmHg-1; P < 0.001), while eight individuals did not (663 ± 165 vs. 667 ± 167 ml·min-1·100 mmHg-1; P = 0.6). Compensatory pressor responses between groups were not different (5.5 ± 5.5 and 9.7 ± 9.5 mmHg; P = 0.2). Forearm blood flow, O2D, and oxygen consumption were all protected in compensators (all P > 0.05) but not in noncompensators, who therefore suffered compromises to exercise performance (6 ± 14 vs. -36 ± 29 N; P = 0.004). Phenotypic differences were not explained by potassium or nitric oxide bioavailability. In conclusion, both compensator and noncompensator vasodilator phenotype responses to a sudden compromise to exercising muscle blood flow are evident. Interindividual differences in the mechanisms governing O2D:demand matching should be considered as factors influencing exercise tolerance. NEW &amp; NOTEWORTHY In healthy young individuals, compromising submaximally exercising muscle perfusion appears to evoke compensatory vasodilation to defend oxygen delivery. Here we report the absence of compensatory vasodilation in 8 of 21 such individuals, despite their vasodilatory capacity and increases in perfusion with increasing exercise intensity being indistinguishable from compensators. The absence of compensation impaired exercise tolerance. These findings suggest that interindividual differences in oxygen delivery:demand matching efficacy affect exercise tolerance and depend on the nature of a delivery:demand matching challenge.

Entities:  

Keywords:  compensatory vasodilation; oxygen delivery; perfusion pressure compromise

Mesh:

Substances:

Year:  2017        PMID: 28706000      PMCID: PMC5867373          DOI: 10.1152/japplphysiol.00952.2016

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  41 in total

1.  Measures of reliability in sports medicine and science.

Authors:  W G Hopkins
Journal:  Sports Med       Date:  2000-07       Impact factor: 11.136

2.  Alveolar oxygen uptake and femoral artery blood flow dynamics in upright and supine leg exercise in humans.

Authors:  M J MacDonald; J K Shoemaker; M E Tschakovsky; R L Hughson
Journal:  J Appl Physiol (1985)       Date:  1998-11

3.  Developing criteria for establishing interrater reliability of specific items: applications to assessment of adaptive behavior.

Authors:  D V Cicchetti; S A Sparrow
Journal:  Am J Ment Defic       Date:  1981-09

4.  Human muscle performance and PCr hydrolysis with varied inspired oxygen fractions: a 31P-MRS study.

Authors:  M C Hogan; R S Richardson; L J Haseler
Journal:  J Appl Physiol (1985)       Date:  1999-04

5.  Contribution of adenosine to compensatory dilation in hypoperfused contracting human muscles is independent of nitric oxide.

Authors:  Darren P Casey; Michael J Joyner
Journal:  J Appl Physiol (1985)       Date:  2011-02-03

Review 6.  Chemical physiology of blood flow regulation by red blood cells: the role of nitric oxide and S-nitrosohemoglobin.

Authors:  David J Singel; Jonathan S Stamler
Journal:  Annu Rev Physiol       Date:  2005       Impact factor: 19.318

7.  Nitric oxide contributes to the augmented vasodilatation during hypoxic exercise.

Authors:  Darren P Casey; Brandon D Madery; Timothy B Curry; John H Eisenach; Brad W Wilkins; Michael J Joyner
Journal:  J Physiol       Date:  2009-11-30       Impact factor: 5.182

8.  K+ is an endothelium-derived hyperpolarizing factor in rat arteries.

Authors:  G Edwards; K A Dora; M J Gardener; C J Garland; A H Weston
Journal:  Nature       Date:  1998-11-19       Impact factor: 49.962

Review 9.  Erythrocytes: oxygen sensors and modulators of vascular tone.

Authors:  Mary L Ellsworth; Christopher G Ellis; Daniel Goldman; Alan H Stephenson; Hans H Dietrich; Randy S Sprague
Journal:  Physiology (Bethesda)       Date:  2009-04

10.  NOS inhibition blunts and delays the compensatory dilation in hypoperfused contracting human muscles.

Authors:  Darren P Casey; Michael J Joyner
Journal:  J Appl Physiol (1985)       Date:  2009-09-03
View more
  3 in total

1.  Dietary nitrate restores compensatory vasodilation and exercise capacity in response to a compromise in oxygen delivery in the noncompensator phenotype.

Authors:  Robert F Bentley; Jeremy J Walsh; Patrick J Drouin; Aleksandra Velickovic; Sarah J Kitner; Alyssa M Fenuta; Michael E Tschakovsky
Journal:  J Appl Physiol (1985)       Date:  2017-06-08

2.  Fatigue-independent alterations in muscle activation and effort perception during forearm exercise: role of local oxygen delivery.

Authors:  P J Drouin; Z I N Kohoko; O K Mew; M J T Lynn; A M Fenuta; M E Tschakovsky
Journal:  J Appl Physiol (1985)       Date:  2019-05-09

3.  Passive hallux adduction decreases lateral plantar artery blood flow: a preliminary study of the potential influence of narrow toe box shoes.

Authors:  Julia L Jacobs; Sarah T Ridge; Dustin A Bruening; K Annie Brewerton; Jayson R Gifford; Daniel M Hoopes; A Wayne Johnson
Journal:  J Foot Ankle Res       Date:  2019-11-04       Impact factor: 2.303

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.