Literature DB >> 28704883

Validity and Reliability of a New Device (WIMU®) for Measuring Hamstring Muscle Extensibility.

José M Muyor1.   

Abstract

The aims of the current study were 1) to evaluate the validity of the WIMU® system for measuring hamstring muscle extensibility in the passive straight leg raise (PSLR) test using an inclinometer for the criterion and 2) to determine the test-retest reliability of the WIMU® system to measure hamstring muscle extensibility during the PSLR test. 55 subjects were evaluated on 2 separate occasions. Data from a Unilever inclinometer and WIMU® system were collected simultaneously. Intraclass correlation coefficients (ICCs) for the validity were very high (0.983-1); a very low systematic bias (-0.21°--0.42°), random error (0.05°-0.04°) and standard error of the estimate (0.43°-0.34°) were observed (left-right leg, respectively) between the 2 devices (inclinometer and the WIMU® system). The R2 between the devices was 0.999 (p<0.001) in both the left and right legs. The test-retest reliability of the WIMU® system was excellent, with ICCs ranging from 0.972-0.995, low coefficients of variation (0.01%), and a low standard error of the estimate (0.19-0.31°). The WIMU® system showed strong concurrent validity and excellent test-retest reliability for the evaluation of hamstring muscle extensibility in the PSLR test. © Georg Thieme Verlag KG Stuttgart · New York.

Mesh:

Year:  2017        PMID: 28704883     DOI: 10.1055/s-0043-108998

Source DB:  PubMed          Journal:  Int J Sports Med        ISSN: 0172-4622            Impact factor:   3.118


  4 in total

1.  Reliability of a Novel Video-Based Method for Assessing Age-Related Changes in Upper Limb Kinematics.

Authors:  Daniel A Pupo; John W Kakareka; Jonathan Krynitsky; Lorenzo Leggio; Tom Pohida; Stephanie Studenski; Brandon K Harvey
Journal:  Front Aging Neurosci       Date:  2018-09-24       Impact factor: 5.750

2.  Validity and Reliability of an Inertial Device for Measuring Dynamic Weight-Bearing Ankle Dorsiflexion.

Authors:  José M Oliva-Lozano; Isabel Martín-Fuentes; José M Muyor
Journal:  Sensors (Basel)       Date:  2020-01-10       Impact factor: 3.576

3.  Validity and Reliability of the Inertial Measurement Unit for Barbell Velocity Assessments: A Systematic Review.

Authors:  Filipe Manuel Clemente; Zeki Akyildiz; José Pino-Ortega; Markel Rico-González
Journal:  Sensors (Basel)       Date:  2021-04-03       Impact factor: 3.576

4.  Validity and Reliability of a New Inertial Device for Monitoring Range of Motion at the Pelvis during Sexual Intercourse.

Authors:  José M Oliva-Lozano; Isabel Martín-Fuentes; José M Muyor
Journal:  Int J Environ Res Public Health       Date:  2020-04-22       Impact factor: 3.390

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.