Literature DB >> 28703444

Comparison of acute toxicities between contemporary forward-planned 3D conformal radiotherapy and inverse-planned intensity-modulated radiotherapy for whole breast radiation.

David M Guttmann1, Peter Gabriel1, Christopher Kennedy1, William Rate1, William Grizos1, Suneel Nagda1, Lisa Wojtowicz1, Lilie Lin1, Gary M Freedman1.   

Abstract

The use of inverse-planned intensity-modulated radiation therapy for whole breast radiation treatment has become more prevalent, but this may impose an increased cost on the health system. We hypothesized that when applied with the same treatment planning goals, tangential forward-planned field-in-field 3D conformal radiotherapy and tangential inverse-planned intensity-modulated radiotherapy would be associated with comparable toxicities. Women who underwent tangential whole breast irradiation at our institution from 2011 to 2015 planned using either forward-planned field-in-field 3D conformal radiotherapy or intensity-modulated radiotherapy were retrospectively analyzed. Grade 2+ Radiation dermatitis was the primary endpoint. A total of 201 and 212 women had undergone field-in-field 3D conformal radiotherapy and intensity-modulated radiotherapy, respectively. No differences were observed between the two modalities regarding acute radiation dermatitis, breast pain, or fatigue. In a multivariable logistic regression that incorporated the use of boost, hypofractionation, use of chemotherapy, patient positioning, use of a supraclavicular field, and breast planning target volume, intensity-modulated radiotherapy was not correlated with different rates of Grade 2+ radiation dermatitis. This study supports the routine first-line use of field-in-field 3D conformal radiotherapy for whole breast radiation instead of tangential intensity-modulated radiotherapy from the standpoint of equivalence in acute toxicity. Further investigation is needed to assess whether there are subgroups of women who may still benefit from intensity-modulated radiotherapy.
© 2017 Wiley Periodicals, Inc.

Entities:  

Keywords:  3D conformal radiation; breast cancer; intensity-modulated radiation therapy; radiation therapy; toxicity

Mesh:

Year:  2017        PMID: 28703444     DOI: 10.1111/tbj.12857

Source DB:  PubMed          Journal:  Breast J        ISSN: 1075-122X            Impact factor:   2.431


  3 in total

1.  Repeat breast-conserving treatment of ipsilateral breast cancer recurrence: a nationwide survey amongst breast surgeons and radiation oncologists in the Netherlands.

Authors:  Coco J E F Walstra; Robert-Jan Schipper; Yvonne E van Riet; Peter-Paul G van der Toorn; Marjolein L Smidt; Maurice J C Vd Sangen; Adri C Voogd; Grard A P Nieuwenhuijzen
Journal:  Breast Cancer Res Treat       Date:  2021-03-13       Impact factor: 4.872

2.  Increase in Superficial Dose in Whole-Breast Irradiation With Halcyon Straight-Through Linac Compared With Traditional C-arm Linac With Flattening Filter: In vivo Dosimetry and Planning Study.

Authors:  Fionnbarr O'Grady; Andrew R Barsky; Shibu Anamalayil; Gary M Freedman; Christopher Kennedy; Bin Cai; Eric Laugeman; Lei Dong; Geoffrey D Hugo; James M Metz; Sasa Mutic; Neil K Taunk; Taoran Li
Journal:  Adv Radiat Oncol       Date:  2019-08-21

3.  Risk Factors Related to Acute Radiation Dermatitis in Breast Cancer Patients After Radiotherapy: A Systematic Review and Meta-Analysis.

Authors:  Yuxiu Xie; Qiong Wang; Ting Hu; Renwang Chen; Jue Wang; Haiyan Chang; Jing Cheng
Journal:  Front Oncol       Date:  2021-11-29       Impact factor: 6.244

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.