Christian Bjurman, Matteus Zywczyk, Bertil Lindahl, Tobias Carlsson, Per Johanson, Max Petzold, Martin Holzmann, Michael Lx Fu, Ola Hammarsten1. 1. Ola Hammarsten, MD, PhD, Professor Senior Physician Conjoint Professor, Newcastle University, Australia Institution of Biochemistry Department of clinical chemistry and transfusion medicine Bruna straket 16 Sahlgrenska academy at the University of Gothenburg SE 413 45 Gothenburg Sweden Email: ola.hammarsten@clinchem.gu.se Phone Lab:+46-31-342 9941 Mobile: +46-733-200834 Fax:+46-31-82 84 58. ola.hammarsten@clinchem.gu.se.
Abstract
BACKGROUND: The implementation of high-sensitivity cardiac troponin T (hs-cTnT) assays and a cutoff based on the 99th cTnT percentile in the evaluation of patients with suspected acute coronary syndrome has not been uniform due to uncertain effects on health benefits and utilization of limited resources. METHODS: Clinical and laboratory data from patients with chest pain or dyspnea at the emergency de¬partment (ED) were evaluated before (n = 20516) and after (n = 18485) the lowering of the hs-cTnT cutoff point from 40 ng/L to the 99th hs-cTnT percentile of 14 ng/L in February 2012. Myocardial infarction (MI) was diagnosed at the discretion of the attending clinicians responsible for the patient. RESULTS: Following lowering of the hs-cTnT cutoff point fewer ED patients with chest pain or dyspnea as the principal complaint were analyzed with an hs-cTnT sample (81% vs. 72%, p < 0.001). Overall 30-day mortality was unaffected but increased among patients not analyzed with an hs-cTnT sample (5.3% vs. 7.6%, p < 0.001). The MI frequency was unchanged (4.0% vs. 3.9%, p = 0.72) whereas admission rates decreased (51% vs. 45%, p < 0.001) as well as hospital costs. Coronary angiographies were used more frequently (2.8% vs. 3.3%, p = 0.004) but with no corresponding change in coronary interventions. CONCLUSIONS: At the participating hospital, lowering of the hs-cTnT cutoff point to the 99th percentile decreased admissions and hospital costs but did not result in any apparent prognostic or treatment benefits for the patients.
BACKGROUND: The implementation of high-sensitivity cardiac troponin T (hs-cTnT) assays and a cutoff based on the 99th cTnT percentile in the evaluation of patients with suspected acute coronary syndrome has not been uniform due to uncertain effects on health benefits and utilization of limited resources. METHODS: Clinical and laboratory data from patients with chest pain or dyspnea at the emergency de¬partment (ED) were evaluated before (n = 20516) and after (n = 18485) the lowering of the hs-cTnT cutoff point from 40 ng/L to the 99th hs-cTnT percentile of 14 ng/L in February 2012. Myocardial infarction (MI) was diagnosed at the discretion of the attending clinicians responsible for the patient. RESULTS: Following lowering of the hs-cTnT cutoff point fewer ED patients with chest pain or dyspnea as the principal complaint were analyzed with an hs-cTnT sample (81% vs. 72%, p < 0.001). Overall 30-day mortality was unaffected but increased among patients not analyzed with an hs-cTnT sample (5.3% vs. 7.6%, p < 0.001). The MI frequency was unchanged (4.0% vs. 3.9%, p = 0.72) whereas admission rates decreased (51% vs. 45%, p < 0.001) as well as hospital costs. Coronary angiographies were used more frequently (2.8% vs. 3.3%, p = 0.004) but with no corresponding change in coronary interventions. CONCLUSIONS: At the participating hospital, lowering of the hs-cTnT cutoff point to the 99th percentile decreased admissions and hospital costs but did not result in any apparent prognostic or treatment benefits for the patients.