Literature DB >> 28695406

Quantification of intramyocardial blood volume with 99mTc-RBC SPECT-CT imaging: A preclinical study.

Hassan Mohy-Ud-Din1,2, Nabil E Boutagy3, John C Stendahl3, Zhen W Zhuang3, Albert J Sinusas4,3, Chi Liu5.   

Abstract

BACKGROUND: Currently, there is no established non-invasive imaging approach to directly evaluate myocardial microcirculatory function in order to diagnose microvascular disease independent of co-existing epicardial disease. In this work, we developed a methodological framework for quantification of intramyocardial blood volume (IMBV) as a novel index of microcirculatory function with SPECT/CT imaging of 99mTc-labeled red blood cells (RBCs).
METHODS: Dual-gated myocardial SPECT/CT equilibrium imaging of 99mTc-RBCs was performed on twelve canines under resting conditions. Five correction schemes were studied: cardiac gating with no other corrections (CG), CG with attenuation correction (CG + AC), CG + AC with scatter correction (CG + AC + SC), dual cardiorespiratory gating with AC + SC (DG + AC + SC), and DG + AC + SC with partial volume correction (DG + AC + SC + PVC). Quantification of IMBV using each approach was evaluated in comparison to those obtained from all corrections. The in vivo SPECT estimates of IMBV values were validated against those obtained from ex vivo microCT imaging of the casted hearts.
RESULTS: The estimated IMBV with all corrections was 0.15 ± 0.03 for the end-diastolic phase and 0.11 ± 0.03 for the end-systolic phase. The cycle-dependent change in IMBVIMBV) with all corrections was 23.9 ± 8.6%. Schemes that applied no correction or partial correction resulted in significant over-estimation of IMBV and significant under-underestimation of ΔIMBV. Estimates of IMBV and ΔIMBV using all corrections were consistent with values reported in the literature using invasive techniques. In vivo SPECT estimates of IMBV strongly correlated (R2 ≥ 0.70) with ex vivo measures for the various correction schemes, while the fully corrected scheme yielded the smallest bias.
CONCLUSIONS: Non-invasive quantification of IMBV is feasible using 99mTc-RBCs SPECT/CT imaging, however, requires full compensation of physical degradation factors.

Entities:  

Keywords:  Intramyocardial blood volume; SPECT-CT imaging; cardio-respiratory motion correction; coronary microcirculation; microCT; partial volume correction

Mesh:

Substances:

Year:  2017        PMID: 28695406      PMCID: PMC5985225          DOI: 10.1007/s12350-017-0970-4

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  2 in total

Review 1.  Nuclear cardiology in the context of multimodality imaging to detect cardiac toxicity from cancer therapeutics: Established and emerging methods.

Authors:  Aaron Soufer; Chi Liu; Mariana L Henry; Lauren A Baldassarre
Journal:  J Nucl Cardiol       Date:  2019-03-13       Impact factor: 3.872

2.  Feasibility study of PET dynamic imaging of [18F]DHMT for quantification of reactive oxygen species in the myocardium of large animals.

Authors:  Jing Wu; Nabil E Boutagy; Zhengxin Cai; Shu-Fei Lin; Ming-Qiang Zheng; Attila Feher; John C Stendahl; Michael Kapinos; Jean-Dominique Gallezot; Hui Liu; Tim Mulnix; Wenjie Zhang; Marcel Lindemann; Jo-Ku Teng; Edward J Miller; Yiyun Huang; Richard E Carson; Albert J Sinusas; Chi Liu
Journal:  J Nucl Cardiol       Date:  2020-05-15       Impact factor: 5.952

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.