Purpose: To determine the effective dynamic range (EDR), retest reliability, and number of discriminable steps (DS) for mesopic and dark-adapted two-color fundus-controlled perimetry (FCP) using the S-MAIA (Scotopic-Macular Integrity Assessment) "micro-perimeter." Methods: In this prospective cross-sectional study, each of the 52 eyes of 52 subjects with various macular diseases (mean age 62.0 ± 16.9 years; range, 19.1-90.1 years) underwent duplicate mesopic (achromatic stimuli, 400-800 nm), dark-adapted cyan (505 nm), and dark-adapted red (627 nm) FCP using a grid of 61 stimuli covering 18° of the central retina. The EDR, the number of DS, and the retest reliability for point-wise sensitivity (PWS) were analyzed. The effects of fixation stability, sensitivity, and age on retest reliability were examined using mixed-effects models. Results: The EDR was 10 to 30 dB with five DS for mesopic and 4 to 17 dB with four DS for dark-adapted cyan and red testing. PWS retest reliability was good among all three types of retinal sensitivity assessments (coefficient of repeatability ±5.79, ±4.72, and ±4.77 dB, respectively) and did not depend on fixation stability or age. PWS had no effect on retest variability in dark-adapted cyan and dark-adapted red testing but had a minor effect in mesopic testing. Conclusions: Combined mesopic and dark-adapted two-color FCP allows for reliable topographic testing of cone and rod function in patients with various macular diseases with and without foveal fixation. Retest reliability is homogeneous across eccentricities and various degrees of scotoma depth, including zones at risk for disease progression. These reliability estimates can serve for the design of future clinical trials.
Purpose: To determine the effective dynamic range (EDR), retest reliability, and number of discriminable steps (DS) for mesopic and dark-adapted two-color fundus-controlled perimetry (FCP) using the S-MAIA (Scotopic-Macular Integrity Assessment) "micro-perimeter." Methods: In this prospective cross-sectional study, each of the 52 eyes of 52 subjects with various macular diseases (mean age 62.0 ± 16.9 years; range, 19.1-90.1 years) underwent duplicate mesopic (achromatic stimuli, 400-800 nm), dark-adapted cyan (505 nm), and dark-adapted red (627 nm) FCP using a grid of 61 stimuli covering 18° of the central retina. The EDR, the number of DS, and the retest reliability for point-wise sensitivity (PWS) were analyzed. The effects of fixation stability, sensitivity, and age on retest reliability were examined using mixed-effects models. Results: The EDR was 10 to 30 dB with five DS for mesopic and 4 to 17 dB with four DS for dark-adapted cyan and red testing. PWS retest reliability was good among all three types of retinal sensitivity assessments (coefficient of repeatability ±5.79, ±4.72, and ±4.77 dB, respectively) and did not depend on fixation stability or age. PWS had no effect on retest variability in dark-adapted cyan and dark-adapted red testing but had a minor effect in mesopic testing. Conclusions: Combined mesopic and dark-adapted two-color FCP allows for reliable topographic testing of cone and rod function in patients with various macular diseases with and without foveal fixation. Retest reliability is homogeneous across eccentricities and various degrees of scotoma depth, including zones at risk for disease progression. These reliability estimates can serve for the design of future clinical trials.
Authors: Maximilian Pfau; Moritz Lindner; Martin Gliem; Julia S Steinberg; Sarah Thiele; Robert P Finger; Monika Fleckenstein; Frank G Holz; Steffen Schmitz-Valckenberg Journal: Eye (Lond) Date: 2018-08-01 Impact factor: 3.775
Authors: Karl G Csaky; Praveen J Patel; Yasir J Sepah; David G Birch; Diana V Do; Michael S Ip; Robyn H Guymer; Chi D Luu; Shamika Gune; Hugh Lin; Daniela Ferrara Journal: Surv Ophthalmol Date: 2019-01-28 Impact factor: 6.048
Authors: Lea D Bennett; Georgiana Metz; Martin Klein; Kirsten G Locke; Areeba Khwaja; David G Birch Journal: Invest Ophthalmol Vis Sci Date: 2019-03-01 Impact factor: 4.799
Authors: Leon von der Emde; Maximilian Pfau; Sarah Thiele; Philipp T Möller; Ruth Hassenrik; Monika Fleckenstein; Frank G Holz; Steffen Schmitz-Valckenberg Journal: Transl Vis Sci Technol Date: 2018-01-09 Impact factor: 3.283
Authors: Leon von der Emde; Maximilian Pfau; Chantal Dysli; Sarah Thiele; Philipp T Möller; Moritz Lindner; Matthias Schmid; Monika Fleckenstein; Frank G Holz; Steffen Schmitz-Valckenberg Journal: Sci Rep Date: 2019-07-31 Impact factor: 4.379
Authors: Evelyn P Semenov; Rebecca Sheplock; Alejandro J Roman; David B McGuigan; Malgorzata Swider; Artur V Cideciyan; Samuel G Jacobson Journal: Transl Vis Sci Technol Date: 2020-12-08 Impact factor: 3.283
Authors: Michalis Georgiou; Navjit Singh; Thomas Kane; Serena Zaman; Nashila Hirji; Jonathan Aboshiha; Neruban Kumaran; Angelos Kalitzeos; Joseph Carroll; Richard G Weleber; Michel Michaelides Journal: Invest Ophthalmol Vis Sci Date: 2020-09-01 Impact factor: 4.925