Literature DB >> 28692170

Expulsions and adverse events following immediate and later insertion of a levonorgestrel-releasing intrauterine system after medical termination of late first- and second-trimester pregnancy: a randomised controlled trial.

R Korjamo1, M Mentula1, O Heikinheimo1.   

Abstract

OBJECTIVES: To compare expulsions and adverse events (AEs) between immediate and delayed insertion of a levonorgestrel-releasing intrauterine system (LNG-IUS) following medical termination of pregnancy (MTOP).
DESIGN: Randomised controlled trial.
SETTING: Helsinki University Hospital, Finland, January 2013-December 2014. POPULATION: Cohorts of 102 (gestational age 64-84 days, late first trimester) and 57 (gestational age 85-140 days, second trimester) women requesting MTOP and LNG-IUS contraception.
METHODS: LNG-IUS insertion occurred immediately (same day) or 2-4 weeks following MTOP. Follow-up visits were at 2-4 weeks, 3 months, and 1 year. MAIN OUTCOME MEASURES: LNG-IUS expulsion by 3 months and 1 year. AEs and bleeding profiles within 3 months.
RESULTS: Following late first-trimester MTOP the LNG-IUS expulsion rates by 3 months were 14 (27.5%) in the immediate-insertion group and two (4.0%) in the delayed-insertion group (risk ratio, RR 6.86; 95% confidence interval, 95% CI 1.64-28.66). By 1 year the expulsion rates were 17 (33.3%) and six (12.0%) (RR 2.78, 95% CI 1.19-6.47). Following second-trimester MTOP LNG-IUS expulsion rates by 3 months and 1 year were five (18.5%) in the immediate-insertion group and one (3.6%) in the delayed-insertion group (RR 5.19, 95% CI 0.65-41.54). No differences in AEs and bleeding profiles emerged between the groups.
CONCLUSIONS: Immediate LNG-IUS insertion after late first- or second-trimester MTOP is feasible, does not increase the complication rate, or alter the uterine bleeding patterns; however, immediate insertion increased the expulsion rate, which may limit the cost-effectiveness. TWEETABLE ABSTRACT: Immediate insertion of LNG-IUS following MTOP at 9-20 weeks of gestation is feasible and safe.
© 2017 Royal College of Obstetricians and Gynaecologists.

Entities:  

Keywords:  Contraception; contraceptive devices; induced termination of pregnancy; intrauterine devices; medical termination of pregnancy

Mesh:

Substances:

Year:  2017        PMID: 28692170     DOI: 10.1111/1471-0528.14813

Source DB:  PubMed          Journal:  BJOG        ISSN: 1470-0328            Impact factor:   6.531


  1 in total

1.  Discontinuation rates of intrauterine contraception due to unfavourable bleeding: a systematic review.

Authors:  Dustin Costescu; Rajinder Chawla; Rowena Hughes; Stephanie Teal; Martin Merz
Journal:  BMC Womens Health       Date:  2022-03-21       Impact factor: 2.809

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.