Literature DB >> 28691308

Assessment of hypertensive cerebrovascular alterations with multiband Look-Locker arterial spin labeling.

Yoojin Lee1, Tae Kim1,2.   

Abstract

PURPOSE: To quantitatively assess the hypertension-induced cerebrovascular alterations by measuring the dynamics of arterial spin labeling (ASL) signals.
MATERIALS AND METHODS: The multiband Look-Locker ASL (MB LL-ASL) technique was evaluated in comparison to a single-band LL-ASL for three healthy subjects. Also, seven healthy subjects were scanned to determine the strength of the vascular crushing gradients applied to separate arterial from tissue ASL signal. With the optimized MB LL-ASL technique, multiple parameters, cerebral blood flow (CBF), transit times to artery (tA ), and capillary (tC ), delivery duration of labeled blood (τ), and arterial blood volume (CBVa ), were simultaneously quantified for age-matched eight control and eight hypertensive subjects with 259 msec of temporal resolution and 20 slices covering the whole-brain region at 3T.
RESULTS: While CBF of hypertensives were comparable with those of normotensives (CBF of normotensives vs. hypertensives = 62.2 ± 6.87 vs. 61.9 ± 8.94 ml/100g/min, P = 0.960 for the whole gray matter), tC and τ were prolonged in hypertensives in most brain regions (tC  = 1.30 ± 0.09 vs. 1.76 ± 0.16 sec, P = 0.034; τ = 1.46 ± 0.10 vs. 2.30 ± 0.22 sec, P = 0.006 for the whole gray matter). Two regions showed the increased CBVa in hypertensives compared to normotensives (hippocampus and thalamus with P = 0.009 and 0.035, respectively).
CONCLUSION: Hypertension slows the perfusion dynamics, while the remaining CBF is unchanged. A detailed characterization of regional cerebrovascular impairments by MB-LL-ASL technique provides better understanding of hypertension-induced cerebrovascular modifications. LEVEL OF EVIDENCE: 1 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;47:663-672.
© 2017 International Society for Magnetic Resonance in Medicine.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28691308     DOI: 10.1002/jmri.25812

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  1 in total

1.  High temporal resolution arterial spin labeling MRI with whole-brain coverage by combining time-encoding with Look-Locker and simultaneous multi-slice imaging.

Authors:  Merlijn C E van der Plas; Wouter M Teeuwisse; Sophie Schmid; Michael Chappell; Matthias J P van Osch
Journal:  Magn Reson Med       Date:  2019-03-03       Impact factor: 4.668

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.