T Preijers1, H C A M Hazendonk2, K Fijnvandraat3, F W G Leebeek4, M H Cnossen2, R A A Mathôt1. 1. Hospital Pharmacy-Clinical Pharmacology, Academic Medical Center Amsterdam, Amsterdam, the Netherlands. 2. Department of Pediatric Hematology, Erasmus University Medical Center - Sophia Children's Hospital Rotterdam, Rotterdam, the Netherlands. 3. Department of Pediatric Hematology, Academic Medical Center Amsterdam, Amsterdam, the Netherlands. 4. Department of Hematology, Erasmus University Medical Center, Rotterdam, the Netherlands.
Abstract
Essentials Individual pharmacokinetic (PK) parameters can be obtained by limited sampling strategies (LSSs). Following 100 IU kg-1 rFIX, LSSs with 1 to 3 samples were evaluated in 5000 simulated subjects. For all LSSs, estimated individual PK parameters showed acceptable bias and precision. One sample between 10 min-3 h and two between 48 h-56 h showed best predictive performance. SUMMARY: Background Patients with severe hemophilia B regularly administer prophylactic intravenous doses of clotting factor IX concentrate to maintain a trough level of at least 0.01 IU mL-1 in order to prevent joint bleeds. Assessment of individual pharmacokinetic (PK) parameters allows individualization of the recombinant factor IX (rFIX) dose. Aim To evaluate the predictive performance of limited sampling strategies (LSSs) with one to three samples to estimate individual PK parameters of rFIX. Methods Monte Carlo simulations were performed to obtain 5000 concentration-time profiles by the use of population PK parameters for rFIX from literature. Eleven LSSs were developed with one, two or three samples taken within an 80-h interval following administration of 100 IU kg-1 rFIX. Clearance (CL), half-life (t1/2 ), time to 1% and steady-state distribution volume (Vss ) were estimated for each simulated individual by the use of Bayesian analysis. Results For each LSS, average bias was small for CL (range - 1.5% to 1.4%), t1/2 (range - 4.5% to - 0.7%), time to 1% (range - 2.9% to 0%), and Vss (range - 3.7% to 0.3%). Imprecision for these parameters ranged from 6.4% to 11.9%, from 10.3% to 15.6%, from 7.3% to 10.9%, and from 9% to 20.1%, respectively. The best predictive performance was achieved with one sample taken between 10 min and 3 h and two samples taken between 48 h and 56 h after administration of rFIX. Conclusions This study demonstrates that limited sampling strategies, used for individualized dosing of rFIX in hemophilia B patients, can be developed and evaluated by in silico simulation.
Essentials Individual pharmacokinetic (PK) parameters can be obtained by limited sampling strategies (LSSs). Following 100 IU kg-1 rFIX, LSSs with 1 to 3 samples were evaluated in 5000 simulated subjects. For all LSSs, estimated individual PK parameters showed acceptable bias and precision. One sample between 10 min-3 h and two between 48 h-56 h showed best predictive performance. SUMMARY: Background Patients with severe hemophilia B regularly administer prophylactic intravenous doses of clotting factor IX concentrate to maintain a trough level of at least 0.01 IU mL-1 in order to prevent joint bleeds. Assessment of individual pharmacokinetic (PK) parameters allows individualization of the recombinant factor IX (rFIX) dose. Aim To evaluate the predictive performance of limited sampling strategies (LSSs) with one to three samples to estimate individual PK parameters of rFIX. Methods Monte Carlo simulations were performed to obtain 5000 concentration-time profiles by the use of population PK parameters for rFIX from literature. Eleven LSSs were developed with one, two or three samples taken within an 80-h interval following administration of 100 IU kg-1 rFIX. Clearance (CL), half-life (t1/2 ), time to 1% and steady-state distribution volume (Vss ) were estimated for each simulated individual by the use of Bayesian analysis. Results For each LSS, average bias was small for CL (range - 1.5% to 1.4%), t1/2 (range - 4.5% to - 0.7%), time to 1% (range - 2.9% to 0%), and Vss (range - 3.7% to 0.3%). Imprecision for these parameters ranged from 6.4% to 11.9%, from 10.3% to 15.6%, from 7.3% to 10.9%, and from 9% to 20.1%, respectively. The best predictive performance was achieved with one sample taken between 10 min and 3 h and two samples taken between 48 h and 56 h after administration of rFIX. Conclusions This study demonstrates that limited sampling strategies, used for individualized dosing of rFIX in hemophilia Bpatients, can be developed and evaluated by in silico simulation.
Authors: Pierre Chelle; Cindy H T Yeung; Stacy E Croteau; Jennifer Lissick; Vinod Balasa; Christina Ashburner; Young Shil Park; Santiago Bonanad; Juan Eduardo Megías-Vericat; Azusa Nagao; Tung Wynn; Fernando Corrales-Medina; Huyen Tran; Anjali Sharathkumar; Meera Chitlur; Samuel Sarmiento; Andrea Edginton; Alfonso Iorio Journal: Clin Pharmacokinet Date: 2020-02 Impact factor: 6.447
Authors: Pierre Chelle; Cindy H T Yeung; Santiago Bonanad; Juan Cristóbal Morales Muñoz; Margareth C Ozelo; Juan Eduardo Megías Vericat; Alfonso Iorio; Jeffrey Spears; Roser Mir; Andrea Edginton Journal: J Pharmacokinet Pharmacodyn Date: 2019-05-21 Impact factor: 2.745
Authors: T Preijers; M W F van Spengler; K Meijer; K Fijnvandraat; K Fischer; F W G Leebeek; M H Cnossen; R A A Mathôt Journal: Eur J Clin Pharmacol Date: 2021-10-15 Impact factor: 2.953
Authors: Tim Preijers; Lisette M Schütte; Marieke J H A Kruip; Marjon H Cnossen; Frank W G Leebeek; Reinier M van Hest; Ron A A Mathôt Journal: Clin Pharmacokinet Date: 2021-01 Impact factor: 6.447