Literature DB >> 28684530

Assessing the use of magnetic resonance imaging virtopsy as an alternative to autopsy: a systematic review and meta-analysis.

Mohammad Usman Ahmad1,2, Kamal Ali Sharif3, Haisum Qayyum1,2, Bushra Ehsanullah4, Svetlana Balyasnikova5,6, Anita Wale5,6, Arun Shanmuganandan7, Muhammed Rafay Sameem Siddiqui7, Thanos Athanasiou8, Graham John Kemp9.   

Abstract

BACKGROUND: The post mortem examination or autopsy is a trusted method of identifying the cause of death. Patients and their families may oppose an autopsy for a variety of reasons, including fear of mutilation or owing to religious and personal beliefs. Imaging alternatives to autopsy have been explored, which may provide a viable alternative.
OBJECTIVE: To explore the possibility of using MRI virtopsy to establish the cause of death as an alternative to the traditional post mortem examination or autopsy.
METHODS: Systematic review was carried out of all studies, without language restriction, identified from Medline, Cochrane (1960-2016) and Embase (1991-2016) up to December 2016. Further searches were performed using the bibliographies of articles and abstracts. All studies reporting the diagnosis of the cause of death by both MRI virtopsy and traditional autopsy were included.
RESULTS: Five studies with 107 patients, contributed to a summative quantitative outcome in adults. The combined sensitivity of MRI virtopsy was 0.82 (95% CI 0.56 to 0.94) with a diagnostic odds ratio (DOR) of 11.1 (95% CI 2.2 to 57.0). There was no significant heterogeneity between studies (Q=1.96, df=4, p=0.75, I2=0). Eight studies, with 953 patients contributed to a summative quantitative outcome in children. The combined sensitivity of MRI virtopsy was 0.73 (95% CI 0.59 to 0.84) with a DOR of 6.44 (95% CI 1.36 to 30.51). There was significant heterogeneity between studies (Q=34.95, df=7, p<0.01, I2=80).
CONCLUSION: MRI virtopsy may offer a viable alternative to traditional autopsy. By using MRI virtopsy, a potential cost reduction of at least 33% is feasible, and therefore ought to be considered in eligible patients. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

Entities:  

Keywords:  MRI; autopsy; imaging; virtopsy

Mesh:

Year:  2017        PMID: 28684530     DOI: 10.1136/postgradmedj-2017-134945

Source DB:  PubMed          Journal:  Postgrad Med J        ISSN: 0032-5473            Impact factor:   2.401


  6 in total

Review 1.  Review: The past, present and future challenges in epilepsy-related and sudden deaths and biobanking.

Authors:  M Thom; M Boldrini; E Bundock; M N Sheppard; O Devinsky
Journal:  Neuropathol Appl Neurobiol       Date:  2018-02       Impact factor: 8.090

2.  Postmortem imaging findings and cause of death determination compared with autopsy: a systematic review of diagnostic test accuracy and meta-analysis.

Authors:  Garyfalia Ampanozi; Delaja Halbheer; Lars C Ebert; Michael J Thali; Ulrike Held
Journal:  Int J Legal Med       Date:  2019-08-27       Impact factor: 2.686

3.  Hospital implementation of minimally invasive autopsy: A prospective cohort study of clinical performance and costs.

Authors:  Ivo M Wagensveld; M G Myriam Hunink; Piotr A Wielopolski; Folkert J van Kemenade; Gabriel P Krestin; Britt M Blokker; J Wolter Oosterhuis; Annick C Weustink
Journal:  PLoS One       Date:  2019-07-16       Impact factor: 3.240

4.  Maceration determines diagnostic yield of fetal and neonatal whole body post-mortem ultrasound.

Authors:  Susan Cheng Shelmerdine; Dean Langan; Uday Mandalia; Neil James Sebire; Owen John Arthurs
Journal:  Prenat Diagn       Date:  2019-11-29       Impact factor: 3.050

5.  Diagnostic accuracy of perinatal post-mortem ultrasound (PMUS): a systematic review.

Authors:  Susan Shelmerdine; Dean Langan; Neil J Sebire; Owen Arthurs
Journal:  BMJ Paediatr Open       Date:  2019-11-11

6.  Diagnostic accuracy of postmortem ultrasound vs postmortem 1.5-T MRI for non-invasive perinatal autopsy.

Authors:  S C Shelmerdine; N J Sebire; O J Arthurs
Journal:  Ultrasound Obstet Gynecol       Date:  2021-03       Impact factor: 7.299

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.