The sutureless Perceval aortic valve (Sorin Group, Saluggia, Italy) is a device increasingly used in many European cardiac surgery centers. Since the first reports evaluating implantation feasibility and valve safety in humans in 2007, an increasing amount of data have become available, including premarketing clinical results and experience in particular conditions. Overall, excellent performances have been demonstrated in hemodynamic outcomes, safety, and versatility of use. However, several questions remain unanswered, especially regarding long-term durability, risk for endocarditis, and the need for postoperative pacemaker implantation. In this article, the most important studies published until now in the literature will be described, providing a state-of-the-art overview of current knowledge as well as future directions and indications for the use of the Perceval valve based on preliminary results of ongoing studies.
Copyright © 2016 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  aortic valve replacement; biological heart prosthesis; minimally invasive surgery; review

Mesh:

Year:  2016        PMID: 28683983     DOI: 10.1053/j.semtcvs.2016.02.013

Source DB:  PubMed          Journal:  Semin Thorac Cardiovasc Surg        ISSN: 1043-0679


  4 in total

1.  Transcatheter valve-in-valve implantation for sutureless bioprosthetic aortic paravalvular leak in the era of COVID-19.

Authors:  Şakir Arslan; Nermin Bayar; Zehra Erkal; Erkan Köklü; Göksel Çağırcı
Journal:  Anatol J Cardiol       Date:  2021-03       Impact factor: 1.596

2.  First experience in Turkey with Meril's MyValTM transcatheter aortic valve-in valve replacement for degenerated PERCEVALTM bioprothesis valve.

Authors:  Mehmet Erdoğan; Ahmet Kasapkara; Selçuk Öztürk; Cem Çöteli; Serdal Baştuğ; Nihal Akar Bayram; Murat Akçay; Tahir Durmaz
Journal:  Anatol J Cardiol       Date:  2022-02       Impact factor: 1.596

3.  Use of a sutureless aortic valve in reoperative aortic valve replacement.

Authors:  Arjune S Dhanekula; Thamanna Nishath; Garbiel S Aldea; Christopher R Burke
Journal:  JTCVS Tech       Date:  2022-02-26

4.  Degenerated Suturless Perceval with (Paravalvular Leak and AS) Treated by Valve in Valve using S3 Edward Valve.

Authors:  Mohammed Ali Balghith
Journal:  Heart Views       Date:  2019-11-14