Literature DB >> 28682132

Inadequate pelvic radiographs: implications of not getting it right the first time.

S Parker1, N S Nagra2, K Kulkarni3, J Pegrum4, S Barry5, R Hughes6, Y Ghani7.   

Abstract

Introduction Pelvic radiography is a frequent investigation. European guidelines aim to ensure appropriate use and adequate quality. When initial images are inadequate, repeat radiographs are often required, which may have significant patient safety and economic implications. Objectives The study aimed to assess the adequacy of pelvic imaging across three orthopaedic centres, to identify causes for inadequate imaging and to establish the cost of inadequate imaging from financial and patient safety perspectives. Methods Pelvic radiographs were identified on Picture Archiving and Communication System software at three UK hospitals. Radiographs were assessed against European guidelines and indications for repeat imaging were analysed. Results A total of 1,531 sequential pelvic radiographs were reviewed. The mean age of patients was 60 years (range 5 months to 101 years). Of this total, 51.9% of images were suboptimal, with no significant difference across the three hospitals (P > 0.05). Hospital 3 repeated radiographs in 6.3% of cases, compare with 18.1% and 19.7% at hospitals 1 and 2, respectively (P > 0.05). Hospital 3 identified pathology missed on the initial radiograph in 1% of cases, compared with 5.4% and 5.5% at hospitals 1 and 2, respectively (P > 0.05). Out-of-hours imaging is associated with a higher rate of suboptimal quality (69.1%) compared with normal working hours (51.3%; P = 0.006). Adequacy rates vary with age (χ 2 = 43.62, P < 0.001). Risk of having a suboptimal radiograph increases above the age of 60-years (χ 2 = 4.45, P < 0.05). The annual cost of repeat radiographs was £56,200 per hospital. Discussion and conclusion High rates of pelvic radiograph inadequacy can lead to missed pathology and the requirement for repeat imaging, which has significant patient safety and financial implications. Risk factors for inadequate radiographs include older patients and those having out-of-hours imaging.

Entities:  

Keywords:  Economics; Orthopaedics; Patient safety; Pelvis

Mesh:

Year:  2017        PMID: 28682132      PMCID: PMC5697041          DOI: 10.1308/rcsann.2017.0095

Source DB:  PubMed          Journal:  Ann R Coll Surg Engl        ISSN: 0035-8843            Impact factor:   1.891


  7 in total

1.  Revised radiation doses for typical X-ray examinations. Report on a recent review of doses to patients from medical X-ray examinations in the UK by NRPB. National Radiological Protection Board.

Authors:  B F Wall; D Hart
Journal:  Br J Radiol       Date:  1997-05       Impact factor: 3.039

2.  England's NHS faces a funding crisis, report says.

Authors:  Nigel Hawkes
Journal:  BMJ       Date:  2014-07-09

3.  RSNA centennial article: ALARA 1912: "As low a dose as possible" a century ago.

Authors:  Alan E Oestreich
Journal:  Radiographics       Date:  2014 Sep-Oct       Impact factor: 5.333

4.  Radiographic assessment of ground-level falls in elderly patients: Is the "PAN-SCAN" overdoing it?

Authors:  Christopher R Dwyer; Aaron M Scifres; Kurt R Stahlfeld; Alain C Corcos; Jenny A Ziembicki; Jessica I Summers; Andrew B Peitzman; Timothy R Billiar; Jason L Sperry
Journal:  Surgery       Date:  2013-10       Impact factor: 3.982

5.  Effective dose and risks from medical X-ray procedures.

Authors:  M I Balonov; P C Shrimpton
Journal:  Ann ICRP       Date:  2012-08-22

6.  Ground-level geriatric falls: a not-so-minor mechanism of injury.

Authors:  Simon Parker; Arash Afsharpad
Journal:  Case Rep Orthop       Date:  2014-11-06

Review 7.  Digital radiography exposure indices: A review.

Authors:  Ursula Mothiram; Patrick C Brennan; Sarah J Lewis; Bernadette Moran; John Robinson
Journal:  J Med Radiat Sci       Date:  2014-05-11
  7 in total
  2 in total

1.  Retrospective Review of Arthroplasty Radiographs: How to Define an Adequate Radiograph.

Authors:  Ahmad Faraz; Mohammad Al-Ashqar; Shoaib Khan; Qamar Zaman; Joshua Smyth; James Parker; Nikhil Bhuskute
Journal:  Cureus       Date:  2022-07-09

2.  Neglected Monteggia Fracture Dislocations in Children: A Case Series.

Authors:  Turki Abdullah S Alajmi
Journal:  J Orthop Case Rep       Date:  2020-10
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.