Integration of deployable fluid lenses and reflectors with endoluminal therapeutic ultrasound applicators: Preliminary investigations of enhanced penetration depth and focal gain.

Matthew S Adams1,2, Vasant A Salgaonkar1, Serena J Scott1, Graham Sommer3, Chris J Diederich1,2.   

Abstract

PURPOSE: Catheter-based ultrasound applicators can generate thermal ablation of tissues adjacent to body lumens, but have limited focusing and penetration capabilities due to the small profile of integrated transducers required for the applicator to traverse anatomical passages. This study investigates a design for an endoluminal or laparoscopic ultrasound applicator with deployable acoustic reflector and fluid lens components, which can be expanded after device delivery to increase the effective acoustic aperture and allow for deeper and dynamically adjustable target depths. Acoustic and biothermal theoretical studies, along with benchtop proof-of-concept measurements, were performed to investigate the proposed design.
METHODS: The design schema consists of an array of tubular transducer(s) situated at the end of a catheter assembly, surrounded by an expandable water-filled conical balloon with a secondary reflective compartment that redirects acoustic energy distally through a plano-convex fluid lens. By controlling the lens fluid volume, the convex surface can be altered to adjust the focal length or collapsed for device insertion or removal. Acoustic output of the expanded applicator assembly was modeled using the rectangular radiator method and secondary sources, accounting for reflection and refraction at interfaces. Parametric studies of transducer radius (1-5 mm), height (3-25 mm), frequency (1.5-3 MHz), expanded balloon diameter (10-50 mm), lens focal length (10-100 mm), lens fluid (silicone oil, perfluorocarbon), and tissue attenuation (0-10 Np/m/MHz) on beam distributions and focal gain were performed. A proof-of-concept applicator assembly was fabricated and characterized using hydrophone-based intensity profile measurements. Biothermal simulations of endoluminal ablation in liver and pancreatic tissue were performed for target depths between 2 and 10 cm.
RESULTS: Simulations indicate that focal gain and penetration depth scale with the expanded reflector-lens balloon diameter, with greater achievable performance using perfluorocarbon lens fluid. Simulations of a 50 mm balloon OD, 10 mm transducer outer diameter (OD), 1.5 MHz assembly in water resulted in maximum intensity gain of ~170 (focal dimensions: ~12 mm length × 1.4 mm width) at ~5 cm focal depth and focal gains above 100 between 24 and 84 mm depths. A smaller (10 mm balloon OD, 4 mm transducer OD, 1.5 MHz) configuration produced a maximum gain of 6 at 9 mm depth. Compared to a conventional applicator with a fixed spherically focused transducer of 12 mm diameter, focal gain was enhanced at depths beyond 20 mm for assembly configurations with balloon diameters ≥ 20 mm. Hydrophone characterizations of the experimental assembly (31 mm reflector/lens diameter, 4.75 mm transducer radius, 1.7 MHz) illustrated focusing at variable depths between 10-70 mm with a maximum gain of ~60 and demonstrated agreement with theoretical simulations. Biothermal simulations (30 s sonication, 75 °C maximum) indicate that investigated applicator assembly configurations, at 30 mm and 50 mm balloon diameters, could create localized ellipsoidal thermal lesions increasing in size from 10 to 55 mm length × 3-6 mm width in liver tissue as target depth increased from 2 to 10 cm.
CONCLUSIONS: Preliminary theoretical and experimental analysis demonstrates that combining endoluminal ultrasound with an expandable acoustic reflector and fluid lens assembly can significantly enhance acoustic focal gain and penetration from inherently smaller diameter catheter-based applicators.
© 2017 American Association of Physicists in Medicine.

Entities:  

Keywords:  acoustic; deployable; endoluminal ultrasound; fluid lens; reflector; therapeutic ultrasound; thermal ablation

Mesh:

Year:  2017        PMID: 28681404      PMCID: PMC5646230          DOI: 10.1002/mp.12458

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  31 in total

1.  Ultrasound power deposition model for the chest wall.

Authors:  E G Moros; X Fan; W L Straube
Journal:  Ultrasound Med Biol       Date:  1999-10       Impact factor: 2.998

2.  Method for MRI-guided conformal thermal therapy of prostate with planar transurethral ultrasound heating applicators.

Authors:  Rajiv Chopra; Mathieu Burtnyk; Masoom A Haider; Michael J Bronskill
Journal:  Phys Med Biol       Date:  2005-10-12       Impact factor: 3.609

3.  Ultrasonic phased arrays with variable geometric focusing for hyperthermia applications.

Authors:  Y J Yoon; P J Benkeser
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1992       Impact factor: 2.725

4.  First experience with endovascular ultrasound renal denervation for the treatment of resistant hypertension.

Authors:  Tom Mabin; Marc Sapoval; Vincent Cabane; Joanne Stemmett; Mano Iyer
Journal:  EuroIntervention       Date:  2012-05-15       Impact factor: 6.534

5.  Endoscopic high-intensity focused US: technical aspects and studies in an in vivo porcine model (with video).

Authors:  Tong Li; Tatiana Khokhlova; Ezekiel Maloney; Yak-Nam Wang; Samantha D'Andrea; Frank Starr; Navid Farr; Kyle Morrison; George Keilman; Joo Ha Hwang
Journal:  Gastrointest Endosc       Date:  2015-03-07       Impact factor: 9.427

6.  Treatment of localised prostate cancer with transrectal high intensity focused ultrasound.

Authors:  J Y Chapelon; M Ribault; F Vernier; R Souchon; A Gelet
Journal:  Eur J Ultrasound       Date:  1999-03

7.  The effects of curved tissue layers on the power deposition patterns of therapeutic ultrasound beams.

Authors:  X Fan; K Hynynen
Journal:  Med Phys       Date:  1994-01       Impact factor: 4.071

8.  Transrectal high-intensity focused ultrasound: minimally invasive therapy of localized prostate cancer.

Authors:  A Gelet; J Y Chapelon; R Bouvier; O Rouvière; Y Lasne; D Lyonnet; J M Dubernard
Journal:  J Endourol       Date:  2000-08       Impact factor: 2.942

9.  Applicators for magnetic resonance-guided ultrasonic ablation of benign prostatic hyperplasia.

Authors:  Graham Sommer; Kim Butts Pauly; Andrew Holbrook; Juan Plata; Bruce Daniel; Donna Bouley; Harcharan Gill; Punit Prakash; Vasant Salgaonkar; Peter Jones; Chris Diederich
Journal:  Invest Radiol       Date:  2013-06       Impact factor: 6.016

10.  Treatment of esophageal tumors using high intensity intraluminal ultrasound: first clinical results.

Authors:  David Melodelima; Frederic Prat; Jacques Fritsch; Yves Theillere; Dominique Cathignol
Journal:  J Transl Med       Date:  2008-06-05       Impact factor: 5.531

View more
  1 in total

1.  Deployable ultrasound applicators for endoluminal delivery of volumetric hyperthermia.

Authors:  Muhammad Zubair; Matthew S Adams; Chris J Diederich
Journal:  Int J Hyperthermia       Date:  2021-08-10       Impact factor: 3.914

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.