Literature DB >> 28680011

Bioresorbable Vascular Scaffolds - Are We Facing a Time of Crisis or One of Breakthrough?

Jeehoon Kang1, Jung-Kyu Han1, Han-Mo Yang1, Kyung Woo Park1, Hyun-Jae Kang1, Bon-Kwon Koo1, Hyo-Soo Kim1.   

Abstract

Current 2nd-generation drug-eluting stents (DES) have dramatically improved clinical outcomes after percutaneous coronary intervention for coronary artery disease. However, DES implantation has major long-term limitations related to the permanent presence of foreign material in the coronary artery. Bioresorbable vascular scaffolds (BVS) were designed to overcome this limitation of permanent metal-based DES. However, because of immature manufacturing technology, BVS have several drawbacks, such as the thicker strut, poor deliverability, poor radio-opacity, poor radial strength, and cumbersome procedure to meet the principle of PSP (Preparation, Sizing, and Post-dilatation). Initial studies indicated that BVS outcomes were non-inferior to those of current DES and recent follow-up data of trials have revealed an additional critical drawback, higher rate of scaffold thrombosis, on the top of the existing limitations of BVS. Thus attention must be paid to the appropriate BVS-specific implantation protocols (i.e., PSP), as well as adequate intensity and duration of dual antiplatelet therapy. In any case, current BVS need further technical evolution to replace current metallic DES in routine clinical use.

Entities:  

Keywords:  Bioresorbable vascular scaffolds; Drug-eluting stents; PSP (Preparation, Sizing, and Post-dilatation); Scaffold thrombosis

Mesh:

Substances:

Year:  2017        PMID: 28680011     DOI: 10.1253/circj.CJ-17-0152

Source DB:  PubMed          Journal:  Circ J        ISSN: 1346-9843            Impact factor:   2.993


  3 in total

1.  Crimping-induced structural gradients explain the lasting strength of poly l-lactide bioresorbable vascular scaffolds during hydrolysis.

Authors:  Karthik Ramachandran; Tiziana Di Luccio; Artemis Ailianou; Mary Beth Kossuth; James P Oberhauser; Julia A Kornfield
Journal:  Proc Natl Acad Sci U S A       Date:  2018-09-17       Impact factor: 11.205

2.  Two-year longitudinal evaluation of a second-generation thin-strut sirolimus-eluting bioresorbable coronary scaffold with hybrid cell design in porcine coronary arteries.

Authors:  Pawel Gasior; Yanping Cheng; Jinggang Xia; Gerard B Conditt; Jennifer C McGregor; Renu Virmani; Juan F Granada; Grzegorz L Kaluza
Journal:  Cardiol J       Date:  2018-08-29       Impact factor: 2.737

Review 3.  Systems, Properties, Surface Modification and Applications of Biodegradable Magnesium-Based Alloys: A Review.

Authors:  Junxiu Chen; Yu Xu; Sharafadeen Kunle Kolawole; Jianhua Wang; Xuping Su; Lili Tan; Ke Yang
Journal:  Materials (Basel)       Date:  2022-07-20       Impact factor: 3.748

  3 in total