| Literature DB >> 28679359 |
Fei Liu1, HuanKai Zhang2, Yunxia Zuo3.
Abstract
BACKGROUND: To investigate the feasibility, effectiveness and safety of bilateral thoracic paravertebral block (TPVB) in the post anesthesia care unit (PACU) for pain relief in participants after laparotomy.Entities:
Keywords: Post anesthesia care unit; Postoperative pain; Thoracic paravertebral block
Mesh:
Substances:
Year: 2017 PMID: 28679359 PMCID: PMC5499096 DOI: 10.1186/s12871-017-0378-3
Source DB: PubMed Journal: BMC Anesthesiol ISSN: 1471-2253 Impact factor: 2.217
Fig. 1Participant recruitment flow chart
Fig. 2Ultrasound guided baliteral thoracic paravertebral block at T8 level. a and b illustrating the plane needle insertion to the right T8 paravertebral space. c and d illustrating the plane needle insertion to the left T8 paravertebral space. TP = Transverse process, TPV = Thoracic paravertebral space
Fig. 3VAS pain scores at rest and cough before and after bilateral TPVB
Fig. 4The changes of systolic blood pressure, diastolic blood pressure and mean blood pressure before and post bilateral TPVB
Binary logistic regression model for risk factors of hypotension after bilateral TPVB
| Variable | Hypotensive group 24 | Non-Hypotensive group 177 | P | OR |
|---|---|---|---|---|
| Sex(male/female) | 18/6 | 120/57 | 0.477 | 1.425 |
| Age | 51 ± 11 | 53 ± 12 | 0.465 | 0.987 |
| Body weight | 63.9 ± 8.8 | 58.8 ± 9.4 | 0.015* | 1.059 |
| Height | 166.2 ± 6.8 | 164.1 ± 7.4 | 0.202 | 1.039 |
| BMI | 22.9 ± 2.6 | 21.8 ± 2.8 | 0.053 | 1.170 |
| Operative time | 205 ± 49 | 174 ± 66 | 0.030* | 1.007 |
| Heart rate | 82 ± 14 | 80 ± 14 | 0.674 | 1.007 |
| Systolic blood pressure | 107 ± 16 | 125 ± 19 | <0.001* | 0.938 |
| Diastolic blood pressure | 71 ± 15 | 78 ± 13 | 0.011* | 0.957 |
| Mean blood pressure | 83 ± 14 | 94 ± 14 | 0.001* | 0.938 |
| VAS pain score rest | 7.6 ± 1.9 | 7.8 ± 1.6 | 0.618 | 0.937 |
| VAS pain score cough | 8.4 ± 1.6 | 8.7 ± 1.3 | 0.381 | 0.873 |
BMI Body Mass Index, VAS Visual Analog Scale,* P < 0.05
Multivariate logistic regression model for risk factors of hypotension
| Variable | Estimate | StdErr | Wald | P | OR |
|---|---|---|---|---|---|
| BW | 0.066 | 0.026 | 6.357 | 0.012 | 1.068 |
| Systolic blood pressure | −0.066 | 0.017 | 15.567 | <0.001 | 0.936 |
BW Body Weight
Fig. 5Heart rate and SPO2 before and after bilateral TPVB