Literature DB >> 28675598

MR-based truncation and attenuation correction in integrated PET/MR hybrid imaging using HUGE with continuous table motion.

Maike E Lindemann1, Mark Oehmigen1, Jan O Blumhagen2, Marcel Gratz1,3, Harald H Quick1,3.   

Abstract

PURPOSE: The objective of this study was to introduce and evaluate a method for MR-based attenuation and truncation correction in phantom and patient measurements to improve PET quantification in PET/MR hybrid imaging.
METHODS: The fully MR-based method HUGE (B0 Homogenization using gradient enhancement) provides field-of-view extension in MR imaging, which can be used for truncation correction and improved PET quantification in PET/MR hybrid imaging. The HUGE method in this recent implementation is combined with continuously moving table data acquisition to provide a seamless nontruncated whole-body data set of the outer patient contours to complete the established standard MR-based Dixon-VIBE data for attenuation correction. The method was systematically evaluated in NEMA standard phantom experiments to investigate the impact of HUGE truncation correction on PET quantification. The method was then applied to 24 oncologic patients in whole-body PET/MR hybrid imaging. The impact of MR-based truncation correction with HUGE on PET data was compared to the impact of the established PET-based MLAA algorithm for contour detection.
RESULTS: In phantom and in all patient measurements, the standard Dixon-VIBE attenuation correction data show geometric distortions and signal truncations at the edges of the MR imaging field-of-view. In contrast, the Dixon-VIBE-based attenuation correction data additionally extended by applying HUGE shows significantly less distortion and truncations and due to the continuously moving table acquisition robustly provides smooth outer contours of the patient arms. In the investigated patient cases, MLAA frequently showed an overestimation of arm volume and associated artifacts limiting contour detection. When applying HUGE, an average relative increase in SUVmean in patients' lesion of 4.2% and for MLAA of 4.6% were measured, when compared to standard Dixon-VIBE only. In specific lesions maximal differences in SUVmean up to 13% for HUGE and 14% for MLAA were measured. Quantification in truncated regions showed maximal differences up to 40% for both, MLAA and HUGE. Average differences in those regions in SUVmean for HUGE are 13.3% and 14.6% for MLAA. In a patient with I-124 radiotracer PET-based MLAA contour detection completely failed in this specific case, whereas HUGE as MR-based approach provided accurate truncation correction.
CONCLUSIONS: The HUGE method for truncation correction combined with continuous table movement extends the lateral MR field-of-view and effectively reduces truncations along the outer contours of the patient's arms in whole-body PET/MR imaging. HUGE as a fully MR-based approach is independent of the choice of radiotracer, thus also offering robust truncation correction in patients that are not injected with Fluordesoxyglucose (FDG) as radiotracer. Therefore, this method improves the standard Dixon MR-based attenuation correction and PET image quantification in whole-body PET/MR imaging applications.
© 2017 American Association of Physicists in Medicine.

Entities:  

Keywords:  FOV extension; PET quantification; attenuation correction; continuous table motion; truncation correction; whole-body PET/MR

Mesh:

Year:  2017        PMID: 28675598     DOI: 10.1002/mp.12449

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  10 in total

1.  MRI-guided attenuation correction in torso PET/MRI: Assessment of segmentation-, atlas-, and deep learning-based approaches in the presence of outliers.

Authors:  Hossein Arabi; Habib Zaidi
Journal:  Magn Reson Med       Date:  2021-09-04       Impact factor: 3.737

Review 2.  Whole-body magnetic resonance imaging: techniques and non-oncologic indications.

Authors:  Mary-Louise C Greer
Journal:  Pediatr Radiol       Date:  2018-08-04

3.  Impact of improved attenuation correction featuring a bone atlas and truncation correction on PET quantification in whole-body PET/MR.

Authors:  Mark Oehmigen; Maike E Lindemann; Marcel Gratz; Julian Kirchner; Verena Ruhlmann; Lale Umutlu; Jan Ole Blumhagen; Matthias Fenchel; Harald H Quick
Journal:  Eur J Nucl Med Mol Imaging       Date:  2017-11-09       Impact factor: 9.236

4.  Evaluation of improved attenuation correction in whole-body PET/MR on patients with bone metastasis using various radiotracers.

Authors:  Hong Grafe; Maike E Lindemann; Verena Ruhlmann; Mark Oehmigen; Nader Hirmas; Lale Umutlu; Ken Herrmann; Harald H Quick
Journal:  Eur J Nucl Med Mol Imaging       Date:  2020-03-03       Impact factor: 9.236

5.  Impact of improved attenuation correction on 18F-FDG PET/MR hybrid imaging of the heart.

Authors:  Maike E Lindemann; Felix Nensa; Harald H Quick
Journal:  PLoS One       Date:  2019-03-25       Impact factor: 3.240

6.  Free-breathing 3D Stack of Stars GRE (StarVIBE) sequence for detecting pulmonary nodules in 18F-FDG PET/MRI.

Authors:  Nils Martin Bruckmann; Julian Kirchner; Janna Morawitz; Lale Umutlu; Wolfgang P Fendler; Ken Herrmann; Ann-Kathrin Bittner; Oliver Hoffmann; Tanja Fehm; Maike E Lindemann; Christian Buchbender; Gerald Antoch; Lino M Sawicki
Journal:  EJNMMI Phys       Date:  2022-02-07

7.  A deep learning-based whole-body solution for PET/MRI attenuation correction.

Authors:  Sahar Ahangari; Anders Beck Olin; Marianne Kinggård Federspiel; Bjoern Jakoby; Thomas Lund Andersen; Adam Espe Hansen; Barbara Malene Fischer; Flemming Littrup Andersen
Journal:  EJNMMI Phys       Date:  2022-08-17

Review 8.  Cardiac PET/MRI-an update.

Authors:  C Rischpler; S G Nekolla; G Heusch; L Umutlu; T Rassaf; P Heusch; K Herrmann; F Nensa
Journal:  Eur J Hybrid Imaging       Date:  2019-01-22

Review 9.  Hybrid cardiac imaging using PET/MRI: a joint position statement by the European Society of Cardiovascular Radiology (ESCR) and the European Association of Nuclear Medicine (EANM).

Authors:  Felix Nensa; Fabian Bamberg; Christoph Rischpler; Leon Menezes; Thorsten D Poeppel; Christian la Fougère; Dietrich Beitzke; Sazan Rasul; Christian Loewe; Konstantin Nikolaou; Jan Bucerius; Andreas Kjaer; Matthias Gutberlet; Niek H Prakken; Rozemarijn Vliegenthart; Riemer H J A Slart; Stephan G Nekolla; Martin L Lassen; Bernd J Pichler; Thomas Schlosser; Alexis Jacquier; Harald H Quick; Michael Schäfers; Marcus Hacker
Journal:  Eur Radiol       Date:  2018-05-02       Impact factor: 5.315

10.  Cardiovascular 18F-fluoride positron emission tomography-magnetic resonance imaging: A comparison study.

Authors:  Jack P M Andrews; Gillian MacNaught; Alastair J Moss; Mhairi K Doris; Tania Pawade; Philip D Adamson; Edwin J R van Beek; Christophe Lucatelli; Martin L Lassen; Philip M Robson; Zahi A Fayad; Jacek Kwiecinski; Piotr J Slomka; Daniel S Berman; David E Newby; Marc R Dweck
Journal:  J Nucl Cardiol       Date:  2019-12-02       Impact factor: 5.952

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.