Application of dual-energy CT to suppression of metal artefact caused by pedicle screw fixation in radiotherapy: a feasibility study using original phantom.

Tianyuan Wang1, Takeaki Ishihara, Atsushi Kono, Naoki Yoshida, Hiroaki Akasaka, Naritoshi Mukumoto, Ryuichi Yada, Yasuo Ejima, Kenji Yoshida, Daisuke Miyawaki, Kenichiro Kakutani, Kotaro Nishida, Noriyuki Negi, Toshiaki Minami, Yuuichi Aoyama, Satoru Takahashi, Ryohei Sasaki.   

Abstract

The objective of the present study was the determination of the potential dosimetric benefits of using metal-artefact-suppressed dual-energy computed tomography (DECT) images for cases involving pedicle screw implants in spinal sites. A heterogeneous spinal phantom was designed for the investigation of the dosimetric effect of the pedicle-screw-related artefacts. The dosimetric comparisons were first performed using a conventional two-directional opposed (AP-PA) plan, and then a volumetric modulated arc therapy (VMAT) plan, which are both used for the treatment of spinal metastases in our institution. The results of Acuros® XB dose-to-medium (Dm) and dose-to-water (Dw) calculations using different imaging options were compared with experimental measurements including the chamber and film dosimetries in the spinal phantom. A dual-energy composition image with a weight factor of  -0.2 and a dual-energy monochromatic image (DEMI) with an energy level of 180 keV were found to have superior abilities for artefact suppression. The Dm calculations revealed greater dosimetric effects of the pedicle screw-related artefacts compared to the Dw calculations. The results of conventional single-energy computed tomography showed that, although the pedicle screws were made from low-Z titanium alloy, the metal artefacts still have dosimetric effects, namely, an average (maximum) Dm error of 4.4% (5.6%) inside the spinal cord for a complex VMAT treatment plan. Our findings indicate that metal-artefact suppression using the proposed DECT (DEMI) approach is promising for improving the dosimetric accuracy near the implants and inside the spinal cord (average (maximum) Dm error of 1.1% (2.0%)).

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28675378     DOI: 10.1088/1361-6560/aa7d7f

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  2 in total

Review 1.  Improving radiation physics, tumor visualisation, and treatment quantification in radiotherapy with spectral or dual-energy CT.

Authors:  Matthijs Ferdinand Kruis
Journal:  J Appl Clin Med Phys       Date:  2021-11-07       Impact factor: 2.102

2.  The advantages of carbon fiber based orthopedic devices in patients who have to undergo radiotherapy.

Authors:  Antonella Soriani; Lidia Strigari; Maria Grazia Petrongari; Vincenzo Anelli; Jacopo Baldi; Nicola Salducca; Roberto Biagini; Carmine Zoccali
Journal:  Acta Biomed       Date:  2020-09-07
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.