Literature DB >> 28675070

Validity of heart rate measurements by the Garmin Forerunner 225 at different walking intensities.

Jomme Claes1, Roselien Buys2, Andrea Avila2, Dewar Finlay3, Alan Kennedy3, Daniel Guldenring3, Werner Budts1, Véronique Cornelissen2.   

Abstract

The accuracy of wrist worn heart rate monitors based on photoplethysmography (PPG) is not fully clinically accepted. Therefore, we aimed to validate heart rate measurements of a commercially available PPG heart rate monitor, i.e. the Garmin Forerunner® 225. Twelve healthy volunteers (six women; mean age: 28 years) performed a treadmill protocol consisting of: five minutes sitting, five minutes standing, 10 minutes walking at 4 km/h, 10 minutes walking at a gradient of 5% and intensity of 4-6 metabolic equivalents (METs), 10 minutes walking at a gradient of 8% and intensity of seven METs or more. Walking speeds were individually determined. Walking bouts were separated by a standardised five minute rest period. Heart rate was measured as the average of the last three minutes standing and of each walking bout. A three lead patch-based electrocardiogram (ECG; Zensor®) was used as criterion method. Statistical analyses included Pearson's correlation (r), paired t-tests, root mean squared error (RMSE) and Bland?Altman plots. The mean values per three minutes of every condition did not differ significantly between the Garmin Forerunner® 225 and the Zensor®. RMSE was 3.01 beats per minute (bpm) or 2.89%. The Bland-Altman bias was 1.57 bpm. Limits of agreement (LoA) were wide, ranging from 32.53 to 29.40 bpm. However, Pearson's r ranged from 0.650 to 0.868 suggesting moderate to strong validity. Generally, mean heart rates, r values, RMSE and the Bland-Altman bias indicated good overall agreement in this sample of healthy adults, but wide LoA are making it difficult to trust individual measurements.

Entities:  

Keywords:  Garmin; Validity; heart rate; photoplethysmography; sports watch

Mesh:

Year:  2017        PMID: 28675070     DOI: 10.1080/03091902.2017.1333166

Source DB:  PubMed          Journal:  J Med Eng Technol        ISSN: 0309-1902


  9 in total

1.  Review of Validity and Reliability of Garmin Activity Trackers.

Authors:  Kelly R Evenson; Camden L Spade
Journal:  J Meas Phys Behav       Date:  2020-06

2.  Recommendations for determining the validity of consumer wearable heart rate devices: expert statement and checklist of the INTERLIVE Network.

Authors:  Jan M Mühlen; Julie Stang; Esben Lykke Skovgaard; Pedro B Judice; Pablo Molina-Garcia; William Johnston; Luís B Sardinha; Francisco B Ortega; Brian Caulfield; Wilhelm Bloch; Sulin Cheng; Ulf Ekelund; Jan Christian Brønd; Anders Grøntved; Moritz Schumann
Journal:  Br J Sports Med       Date:  2021-01-04       Impact factor: 13.800

3.  Using Fitness Trackers and Smartwatches to Measure Physical Activity in Research: Analysis of Consumer Wrist-Worn Wearables.

Authors:  André Henriksen; Martin Haugen Mikalsen; Ashenafi Zebene Woldaregay; Miroslav Muzny; Gunnar Hartvigsen; Laila Arnesdatter Hopstock; Sameline Grimsgaard
Journal:  J Med Internet Res       Date:  2018-03-22       Impact factor: 5.428

4.  Accuracy of Apple Watch Measurements for Heart Rate and Energy Expenditure in Patients With Cardiovascular Disease: Cross-Sectional Study.

Authors:  Roselien Buys; Maarten Falter; Werner Budts; Kaatje Goetschalckx; Véronique Cornelissen
Journal:  JMIR Mhealth Uhealth       Date:  2019-03-19       Impact factor: 4.773

5.  Validity and Reliability of Three Commercially Available Smart Sports Bras during Treadmill Walking and Running.

Authors:  James W Navalta; Gabriela Guzman Ramirez; Crystal Maxwell; Kara N Radzak; Graham R McGinnis
Journal:  Sci Rep       Date:  2020-04-30       Impact factor: 4.379

6.  Feasibility of a home-based physiotherapy intervention to promote post-stroke mobility: A randomized controlled pilot study.

Authors:  Ameerani Jarbandhan; Jerry Toelsie; DirkJan Veeger; Robbert Bipat; Luc Vanhees; Roselien Buys
Journal:  PLoS One       Date:  2022-03-07       Impact factor: 3.240

7.  Accuracy of wrist-worn wearable devices for determining exercise intensity.

Authors:  Wei-Te Ho; Yi-Jen Yang; Tung-Chou Li
Journal:  Digit Health       Date:  2022-09-04

8.  Reliability and Validity of Commercially Available Wearable Devices for Measuring Steps, Energy Expenditure, and Heart Rate: Systematic Review.

Authors:  Daniel Fuller; Emily Colwell; Jonathan Low; Kassia Orychock; Melissa Ann Tobin; Bo Simango; Richard Buote; Desiree Van Heerden; Hui Luan; Kimberley Cullen; Logan Slade; Nathan G A Taylor
Journal:  JMIR Mhealth Uhealth       Date:  2020-09-08       Impact factor: 4.773

9.  Validity of the Polar Vantage M watch when measuring heart rate at different exercise intensities.

Authors:  Tricia Shumate; Magdalen Link; James Furness; Kevin Kemp-Smith; Vini Simas; Mike Climstein
Journal:  PeerJ       Date:  2021-02-09       Impact factor: 2.984

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.