Literature DB >> 28668772

Field-effect transition sensor for KI detection based on self-assembled calixtube monolayers.

Kirill Puchnin1, Mariia Andrianova2, Alexander Kuznetsov2, Vladimir Kovalev3.   

Abstract

A series of novel calixarene-based tubes comprising different numbers of silatrane anchoring groups was synthesized. For the first time, a self-assembled monolayer (SAM) derived from calixtubes was formed on a SiO2 surface. The formation of the SAM was confirmed by X-ray photoelectron spectroscopy, scanning electron microscopy-energy dispersive X-ray analysis, and contact angle measurements. Modification of the sensitive surface of a conventional ion-selective field effect transistor (ISFET) with the afforded SAM resulted in the production of a KI-sensitive sensor. This sensor selectively determined KI compare to different alkali metal iodides: NaI, RbI, CsI; also investigation of different potassium salts (acetate, iodide, nitrate, chloride, dihydrophosphate, perchlorate) showed the highest response to KI. This sensor was successfully employed to determine the presence of KI in artificial saliva with a limit of detection of ~3 × 10-8 М. In addition, it was found that the detection limit of the sensor could be increased by combining the sensor with a microfluidic system. Due to the obtained sensor sensitivity and its ability to detect KI in artificial saliva, we could conclude that this sensor shows great potential for application in the determination of KI in different media, such as the human body and in biological liquids, such as saliva or urine.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Calixarene; Host-guest system; ISFET; Potassium iodide; Self-assembled monolayer; Thin film

Mesh:

Substances:

Year:  2017        PMID: 28668772     DOI: 10.1016/j.bios.2017.06.050

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  2 in total

Review 1.  Recent advances in nanowires-based field-effect transistors for biological sensor applications.

Authors:  Rafiq Ahmad; Tahmineh Mahmoudi; Min-Sang Ahn; Yoon-Bong Hahn
Journal:  Biosens Bioelectron       Date:  2017-09-18       Impact factor: 10.618

2.  In Situ Vapor Polymerization of Poly(3,4-ethylenedioxythiophene) Coated SnO₂-Fe₂O₃ Continuous Electrospun Nanotubes for Rapid Detection of Iodide Ions.

Authors:  Xiuru Xu; Wei Wang; Bolun Sun; Xue Zhang; Rui Zhao; Ce Wang
Journal:  Materials (Basel)       Date:  2018-10-24       Impact factor: 3.623

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.