Literature DB >> 28668063

Highly accurate intensity factors of pure CO2 lines near 2 μm.

T A Odintsova1, E Fasci1, L Moretti1, E J Zak2, O L Polyansky2, J Tennyson2, L Gianfrani1, A Castrillo1.   

Abstract

Line intensities for carbon dioxide are measured with a novel spectroscopic approach, assisted by an optical frequency comb synthesizer for frequency calibration purposes. The main feature of the spectrometer consists in the exploitation of optical feedback from a V-shaped high-finesse optical resonator to effectively narrow a distributed feedback diode laser at the wavelength of 2 μm. Laser-gas interaction takes place inside an isothermal cell, which is placed on the transmission from the cavity. High quality, self-calibrated, absorption spectra are observed in pure CO2 samples at different gas pressures, in coincidence with three lines of the R-branch of the ν1 + 2ν2 + ν3 band. Line intensities are determined using a global fitting approach in which a manifold of spectra are simultaneously analyzed across the range of pressures between 5 and 100 Torr, sharing a restricted number of unknown parameters. Various sources of uncertainty have been identified and carefully quantified, thus leading to an overall uncertainty ranging between 0.17% and 0.23%. The measured values are in a very good agreement with recent ab initio predictions.

Entities:  

Year:  2017        PMID: 28668063     DOI: 10.1063/1.4989925

Source DB:  PubMed          Journal:  J Chem Phys        ISSN: 0021-9606            Impact factor:   3.488


  4 in total

1.  High-accuracy 12C16O2 line intensities in the 2 μm wavelength region measured by frequency-stabilized cavity ring-down spectroscopy.

Authors:  Hongming Yi; Qingnan Liu; Lyn Gameson; Adam J Fleisher; Joseph T Hodges
Journal:  J Quant Spectrosc Radiat Transf       Date:  2017-12-13       Impact factor: 2.468

2.  High-accuracy water potential energy surface for the calculation of infrared spectra.

Authors:  Irina I Mizus; Aleksandra A Kyuberis; Nikolai F Zobov; Vladimir Yu Makhnev; Oleg L Polyansky; Jonathan Tennyson
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2018-03-13       Impact factor: 4.226

3.  Optical Measurement of Radiocarbon below Unity Fraction Modern by Linear Absorption Spectroscopy.

Authors:  Adam J Fleisher; David A Long; Qingnan Liu; Lyn Gameson; Joseph T Hodges
Journal:  J Phys Chem Lett       Date:  2017-09-11       Impact factor: 6.475

4.  Cavity ring-down spectroscopy of CO2 near λ = 2.06 μm: Accurate transition intensities for the Orbiting Carbon Observatory-2 (OCO-2) "strong band".

Authors:  Hélène Fleurbaey; Hongming Yi; Erin M Adkins; Adam J Fleisher; Joseph T Hodges
Journal:  J Quant Spectrosc Radiat Transf       Date:  2020       Impact factor: 2.468

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.