| Literature DB >> 28665636 |
M Endrizzi1, F A Vittoria1, L Rigon2,3, D Dreossi4, F Iacoviello5, P R Shearing5, A Olivo1.
Abstract
We present a multiaperture analyzer setup for performing x-ray phase contrast imaging in planar and three-dimensional modalities. The method is based on strongly structuring the x-ray beam with an amplitude modulator, before it reaches the sample, and on a multiaperture analyzing element before detection. A multislice representation of the sample is used to establish a quantitative relation between projection images and the corresponding three-dimensional distributions, leading to successful tomographic reconstruction. Sample absorption, phase, and scattering are retrieved from the measurement of five intensity projections. The method is tested on custom-built phantoms with synchrotron radiation: sample absorption and phase can be reliably retrieved also in combination with strong scatterers, simultaneously attaining high sensitivity and dynamic range.Year: 2017 PMID: 28665636 DOI: 10.1103/PhysRevLett.118.243902
Source DB: PubMed Journal: Phys Rev Lett ISSN: 0031-9007 Impact factor: 9.161