Literature DB >> 28661912

Favorable Effects on Pulmonary Vascular Hemodynamics with Continuous-Flow Left Ventricular Assist Devices Are Sustained 5 Years After Heart Transplantation.

Abdulfattah Saidi1, Craig H Selzman, Abdulmohsin Ahmadjee, Mohammad Al-Sarie, Gregory L Snow, Omar Wever-Pinzon, Rami Alharethi, Bruce Reid, Josef Stehlik, Abdallah G Kfoury, Feras Bader.   

Abstract

It is unclear whether pulmonary hemodynamics improvement with left ventricle unloading with left ventricular assist devices (LVADs) is sustained long term after heart transplant (HT). We sought to assess the effects on pulmonary vascular hemodynamics during continuous-flow (CF-LVAD) and pulsatile flow (PF-LVAD) support up to 5 years after HT. Invasive hemodynamics were evaluated before LVAD, before HT, and at 3 months, 1, and 3-5 years posttransplant. Thirty-eight patients were included in the study and divided into two groups according to the type of LVAD support. The two groups were well matched in age and gender. Mean pulmonary artery pressure (PAPm) and systolic PAP (PAPs) improved significantly in the PF-LVAD group (40 ± 10.6 to 19.8 ± 4.4 mm Hg and 62.7 ± 14.9 to 31.8 ± 5.9 mm Hg, respectively) and in the CF-LVAD group (37.4 ± 11.6 to 22.4 ± 7.7 mm Hg and 53.7 ± 18.0 to 34.6 ± 11.8 mm Hg, respectively). Reductions in PAPm and PAPs were more pronounced in PF-LVAD group than in CF-LVAD group (p = 0.005 and p = 0.03, respectively). After HT, the improvement in PAPm and PAPs was sustained after 3-5 years in patients who received PF-LVAD (22.6 ± 6.5 and 32.2 ± 9.2 mm Hg, respectively) and in patients who received CF-LVAD (22.2 ± 8.4 and 33.8 ± 9.6 mm Hg, respectively). In conclusion, long-term LVAD support resulted in significant improvement in PAPm and PAPs regardless of the pump generation. The improvement in hemodynamics observed during LVAD support was sustained 3-5 years posttransplant.

Entities:  

Mesh:

Year:  2018        PMID: 28661912     DOI: 10.1097/MAT.0000000000000614

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  3 in total

1.  Computational analysis of the hemodynamic characteristics under interaction influence of β-blocker and LVAD.

Authors:  Kaiyun Gu; Zhe Zhang; Yu Chang; Bin Gao; Feng Wan
Journal:  Biomed Eng Online       Date:  2018-12-03       Impact factor: 2.819

2.  Impact of bridging with left ventricular assist device on right ventricular function following heart transplantation.

Authors:  Annika Ingvarsson; Grunde Gjesdal; Saeideh Borgenvik; Anna Werther Evaldsson; Johan Waktare; Oscar Braun; Gustav J Smith; Anders Roijer; Göran Rådegran; Carl Meurling
Journal:  ESC Heart Fail       Date:  2022-03-23

3.  Changes in pulmonary artery pressure before and after left ventricular assist device implantation in patients utilizing remote haemodynamic monitoring.

Authors:  Ahmet Kilic; Jason N Katz; Susan M Joseph; Meredith A Brisco-Bacik; Nir Uriel; Brian Lima; Rahul Agarwal; Rupinder Bharmi; David J Farrar; Sangjin Lee
Journal:  ESC Heart Fail       Date:  2018-10-23
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.