Literature DB >> 28660675

Objectively improving appropriateness of absorbent products provision to patients with urinary incontinence: The DIAPPER study.

Emilio Sacco1, Riccardo Bientinesi1, Carlo Gandi1, Giuseppe Palermo1, Francesco Pierconti1, Pierfrancesco Bassi1.   

Abstract

AIMS: To objectively assess and enhance the appropriateness of continence products provision to sufferers from urinary incontinence (UI) managed with containment strategies.
METHODS: Incontinent patients of five Italian continence care services were included in this industry-supported study from 01/2012 to 03/2016. All patients/carers have been invited to perform a 48-h home-based pad test and to fill in a diary. The primary outcome was the product appropriateness defined as the use of a pad with maximum absorbent capacity (MAC) from 30% to 50% higher than the individually measured urine load. Pads provision was corrected accordingly. Meaningful factors affecting products appropriateness and patient's satisfaction with the new products were also assessed.
RESULTS: The study included 14 493 subjects (mean age 78 years; 26% males, 74% females) using overall during the study days 98 362 pads. Sixty percent of the products were found to be not appropriate. In most of cases, (75%) products were inappropriate because too large. Age and pad weight gain, followed by gender, body weight, waist circumference, level of autonomy and mobility, pad wearing time, skin health status, and health district were independently associated to the propensity to inappropriateness. After correction of products prescription, a significant reduction (-31%) of the use of largest products was observed. At 6 months evaluation, 88% of evaluable participants were satisfied with the new prescription.
CONCLUSIONS: Most of patients are provided with not appropriate containment products. The use of the 48-h pad test allows improving on an individual basis the appropriateness of products provision.
© 2017 Wiley Periodicals, Inc.

Entities:  

Keywords:  continence products; pad test; pads provision; urinary incontinence

Mesh:

Year:  2017        PMID: 28660675     DOI: 10.1002/nau.23335

Source DB:  PubMed          Journal:  Neurourol Urodyn        ISSN: 0733-2467            Impact factor:   2.696


  1 in total

1.  Association of Supply Source with Continence Product and Care Satisfaction in Patients with Urinary Incontinence.

Authors:  Nina Grotenhuis; Miranda C Schreuder; Tine W L van den Bos; Henk van der Worp; Marco H Blanker
Journal:  Patient Prefer Adherence       Date:  2022-08-15       Impact factor: 2.314

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.