Literature DB >> 28658908

An In vitro Comparative Evaluation of Disinfectants on Standard and Clinical Microbial Strains on Heat Cure Resins.

Karuna Gajanan Pawashe1, Shivsagar Tewary2, Pronob Kumar Sanyal3, Kumar Nilesh4.   

Abstract

INTRODUCTION: Oral cavity is colonised by numerous micro-organisms that form a biofilm on the acrylic resin. Hence, routine hygiene is essential to prevent oral mucosal inflammation and lesions. Knowledge of appropriate disinfecting agents for acrylic resins is crucial in this context. AIM: To compare and evaluate the effectiveness of four commercially available disinfectants on heat cure acrylic resin specimens contaminated with standard and clinical strains of two micro-organisms commonly inhabiting the oral microflora.
MATERIALS AND METHODS: Two hundred acrylic resin specimens (n=200), 10 in each group were contaminated in vitro with 1x106 cells/ml suspensions of standard and clinical strains of micro-organisms (Candida albicans and Streptococcus mutans) and were immersed in four disinfectants (1% sodium hypochlorite, 2% chlorhexidine digluconate, 2% glutaraldehyde and 3.8% sodium perborate) for 10 minutes. The control group was not subjected to any disinfection process. For collection of clinical strains, oral swab was passed over the buccal mucosa and grown on blood agar culture media. Organism confirmation was done by growing them on selective culture media. Final counts of micro-organisms per ml were performed by plating method for evaluation of microbial level reduction. Results obtained were subjected to ANOVA and Tukey's test.
RESULTS: Standard strains of Candida albicans (C) and Streptoccocus mutans (S) subjected to various disinfectants showed varied mean Colony Forming Units per ml (CFU/ml) from <10,000 to 25,000 and <10000 to <50,000 respectively. Clinical strains and of Candida albicans (C) and Streptococcus mutans (S) subjected to various disinfectants showed varied mean CFU/ml from <10,000 to 50,000 and from 10,000 to 50,000 respectively. Control groups showed maximum mean CFU/ml (>105). All intergroup comparisons were highly significant (p<0.001; HS) and intragroup comparisons were significant (p<0.05; S) except the comparison of clinical strains of Streptococcusmutans subjected to 2% chlorhexidine digluconate and 2% glutaraldehyde which was found to be non significant (p>0.05; NS).
CONCLUSION: Almost 1% sodium hypochlorite was found to be the most effective disinfectant for both Candida albicans and Streptococcus mutans. The least effective disinfectant being: 3.8% sodium perborate.

Entities:  

Keywords:  Acrylic resin denture; Candida albicans; Chlorhexidine; Disinfection; Glutaraldehyde; Sodium hypochlorite; Sodium perborate; Streptococcus mutans

Year:  2017        PMID: 28658908      PMCID: PMC5483810          DOI: 10.7860/JCDR/2017/24759.9866

Source DB:  PubMed          Journal:  J Clin Diagn Res        ISSN: 0973-709X


  26 in total

1.  An infection control protocol: effectiveness of immersion solutions to reduce the microbial growth on dental prostheses.

Authors:  A C Pavarina; A C Pizzolitto; A L Machado; C E Vergani; E T Giampaolo
Journal:  J Oral Rehabil       Date:  2003-05       Impact factor: 3.837

2.  The presence and identification of organisms transmitted to dental laboratories.

Authors:  G L Powell; R D Runnells; B A Saxon; B K Whisenant
Journal:  J Prosthet Dent       Date:  1990-08       Impact factor: 3.426

Review 3.  Role of disinfectants in infection control.

Authors:  J A Molinari; R R Runnells
Journal:  Dent Clin North Am       Date:  1991-04

4.  Use of microwave energy to disinfect a long-term soft lining material contaminated with Candida albicans or Staphylococcus aureus.

Authors:  A Baysan; R Whiley; P S Wright
Journal:  J Prosthet Dent       Date:  1998-04       Impact factor: 3.426

Review 5.  The significance of Candida albicans in denture stomatitis.

Authors:  E Budtz-Jörgensen
Journal:  Scand J Dent Res       Date:  1974

6.  Effect of disinfectants on the hardness and roughness of reline acrylic resins.

Authors:  Andrea Azevedo; Ana Lucia Machado; Carlos Eduardo Vergani; Eunice Teresinha Giampaolo; Ana Cláudia Pavarina; Romeo Magnani
Journal:  J Prosthodont       Date:  2006 Jul-Aug       Impact factor: 2.752

7.  Denture plaque and denture cleansers.

Authors:  D C Abelson
Journal:  J Prosthet Dent       Date:  1981-04       Impact factor: 3.426

8.  Adherence of Candida albicans to experimental denture soft lining materials.

Authors:  M G Waters; D W Williams; R G Jagger; M A Lewis
Journal:  J Prosthet Dent       Date:  1997-03       Impact factor: 3.426

9.  An in vitro study into the effect of a limited range of denture cleaners on surface roughness and removal of Candida albicans from conventional heat-cured acrylic resin denture base material.

Authors:  Z Harrison; A Johnson; C W I Douglas
Journal:  J Oral Rehabil       Date:  2004-05       Impact factor: 3.837

10.  Adherence of Candida species to newly polymerized and water-stored denture base polymers.

Authors:  T Waltimo; P Vallittu; M Haapasalo
Journal:  Int J Prosthodont       Date:  2001 Sep-Oct       Impact factor: 1.681

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.