Literature DB >> 28657140

Evaluation of microextraction by packed sorbent, liquid-liquid microextraction and derivatization pretreatment of diet-derived phenolic acids in plasma by gas chromatography with triple quadrupole mass spectrometry.

Luis Bustamante1, Diana Cárdenas1, Dietrich von Baer1, Edgar Pastene2, Daniel Duran-Sandoval3, Carola Vergara1, Claudia Mardones1.   

Abstract

Miniaturized sample pretreatments for the analysis of phenolic metabolites in plasma, involving protein precipitation, enzymatic deconjugation, extraction procedures, and different derivatization reactions were systematically evaluated. The analyses were conducted by gas chromatography with mass spectrometry for the evaluation of 40 diet-derived phenolic compounds. Enzyme purification was necessary for the phenolic deconjugation before extraction. Trimethylsilanization reagent and two different tetrabutylammonium salts for derivatization reactions were compared. The optimum reaction conditions were 50 μL of trimethylsilanization reagent at 90°C for 30 min, while tetrabutylammonium salts were associated with loss of sensitivity due to rapid activation of the inert gas chromatograph liner. Phenolic acids extractions from plasma were optimized. Optimal microextraction by packed sorbent performance was achieved using an octadecylsilyl packed bed and better recoveries for less polar compounds, such as methoxylated derivatives, were observed. Despite the low recovery for many analytes, repeatability using an automated extraction procedure in the gas chromatograph inlet was 2.5%. Instead, using liquid-liquid microextraction, better recoveries (80-110%) for all analytes were observed at the expense of repeatability (3.8-18.4%). The phenolic compounds in gerbil plasma samples, collected before and 4 h after the administration of a calafate extract, were analyzed with the optimized methodology.
© 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

Entities:  

Keywords:  derivatization; microextraction; phenolic acids; plasma; targeted metabolomics

Mesh:

Substances:

Year:  2017        PMID: 28657140     DOI: 10.1002/jssc.201700343

Source DB:  PubMed          Journal:  J Sep Sci        ISSN: 1615-9306            Impact factor:   3.645


  2 in total

1.  Analysis of phenylcarboxylic acid-type microbial metabolites by microextraction by packed sorbent from blood serum followed by GC-MS detection.

Authors:  Alisa K Pautova; Pavel D Sobolev; Alexander I Revelsky
Journal:  Clin Mass Spectrom       Date:  2019-05-23

2.  [Research progress of microextraction by packed sorbent and its application in microvolume sample extraction].

Authors:  Jianan Wei; Molin Qin; Junchao Yang; Liu Yang
Journal:  Se Pu       Date:  2021-03
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.