Revisiting the Cramér Rao Lower Bound for Elastography: Predicting the Performance of Axial, Lateral and Polar Strain Elastograms.

Prashant Verma1, Marvin M Doyley2.   

Abstract

We derived the Cramér Rao lower bound for 2-D estimators employed in quasi-static elastography. To illustrate the theory, we modeled the 2-D point spread function as a sinc-modulated sine pulse in the axial direction and as a sinc function in the lateral direction. We compared theoretical predictions of the variance incurred in displacements and strains when quasi-static elastography was performed under varying conditions (different scanning methods, different configuration of conventional linear array imaging and different-size kernels) with those measured from simulated or experimentally acquired data. We performed studies to illustrate the application of the derived expressions when performing vascular elastography with plane wave and compounded plane wave imaging. Standard deviations in lateral displacements were an order higher than those in axial. Additionally, the derived expressions predicted that peak performance should occur when 2% strain is applied, the same order of magnitude as observed in simulations (1%) and experiments (1%-2%). We assessed how different configurations of conventional linear array imaging (number of active reception and transmission elements) influenced the quality of axial and lateral strain elastograms. The theoretical expressions predicted that 2-D echo tracking should be performed with wide kernels, but the length of the kernels should be selected using knowledge of the magnitude of the applied strain: specifically, longer kernels for small strains (<5%) and shorter kernels for larger strains. Although the general trends of theoretical predictions and experimental observations were similar, biases incurred during beamforming and subsample displacement estimation produced noticeable differences.
Copyright © 2017 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

Keywords:  Cramér Rao lower bound; Elastography; Quasi-static; Strain filter

Mesh:

Year:  2017        PMID: 28655468     DOI: 10.1016/j.ultrasmedbio.2017.05.019

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  3 in total

1.  Locally optimized correlation-guided Bayesian adaptive regularization for ultrasound strain imaging.

Authors:  Rashid Al Mukaddim; Nirvedh H Meshram; Tomy Varghese
Journal:  Phys Med Biol       Date:  2020-03-19       Impact factor: 3.609

2.  Visualizing Angle-Independent Principal Strains in the Longitudinal View of the Carotid Artery: Phantom and In Vivo Evaluation.

Authors:  Rohit Nayak; Giovanni Schifitto; Marvin M Doyley
Journal:  Ultrasound Med Biol       Date:  2018-04-22       Impact factor: 2.998

3.  A comparison between unfocused and focused transmit strategies in cardiac strain imaging.

Authors:  Vincent Sayseng; Julien Grondin; Rachel A Weber; Elisa Konofagou
Journal:  Phys Med Biol       Date:  2020-01-24       Impact factor: 3.609

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.