Literature DB >> 28653507

T1 nuclear magnetic relaxation dispersion of hyperpolarized sodium and cesium hydrogencarbonate-13 C.

Francisco M Martínez-Santiesteban1, Thien Phuoc Dang1, Heeseung Lim1, Albert P Chen2, Timothy J Scholl1,3.   

Abstract

In vivo pH mapping in tissue using hyperpolarized hydrogencarbonate-13 C has been proposed as a method to study tumor growth and treatment and other pathological conditions related to pH changes. The finite spin-lattice relaxation times (T1 ) of hyperpolarized media are a significant limiting factor for in vivo imaging. Relaxation times can be measured at standard magnetic fields (1.5 T, 3.0 T etc.), but no such data are available at low fields, where T1 values can be significantly shorter. This information is required to determine the potential loss of polarization as the agent is dispensed and transported from the polarizer to the MRI scanner. The purpose of this study is to measure T1 dispersion from low to clinical magnetic fields (0.4 mT to 3.0 T) of different hyperpolarized hydrogencarbonate formulations previously proposed in the literature for in vivo pH measurements. 13 C-enriched cesium and sodium hydrogencarbonate preparations were hyperpolarized using dynamic nuclear polarization, and the T1 values of different samples were measured at different magnetic field strengths using a fast field-cycling relaxometer and a 3.0 T clinical MRI system. The effects of deuterium oxide as a dissolution medium for sodium hydrogencarbonate were also analyzed. This study finds that the cesium formulation has slightly shorter T1 values compared with the sodium preparation. However, the higher solubility of cesium hydrogencarbonate-13 C means it can be polarized at greater concentration, using less trityl radical than sodium hydrogencarbonate-13 C. This study also establishes that the preparation and handling of sodium hydrogencarbonate formulations in relation to cesium hydrogencarbonate is more difficult, due to the higher viscosity and lower achievable concentrations, and that deuterium oxide significantly increases the T1 of sodium hydrogencarbonate solutions. Finally, this work also investigates the influence of pH on the spin-lattice relaxation of cesium hydrogencarbonate-13 C measured over a pH range of 7 to 9 at 0.47 T.
Copyright © 2017 John Wiley & Sons, Ltd.

Entities:  

Keywords:  13C-cesium bicarbonate; 13C-sodium bicarbonate; MRS and MRSI methods; T1 nuclear magnetic relaxation dispersion; hyperpolarized 13C; relaxometry

Mesh:

Substances:

Year:  2017        PMID: 28653507     DOI: 10.1002/nbm.3749

Source DB:  PubMed          Journal:  NMR Biomed        ISSN: 0952-3480            Impact factor:   4.044


  3 in total

1.  Using bidirectional chemical exchange for improved hyperpolarized [13 C]bicarbonate pH imaging.

Authors:  David E Korenchan; Jeremy W Gordon; Sukumar Subramaniam; Renuka Sriram; Celine Baligand; Mark VanCriekinge; Robert Bok; Daniel B Vigneron; David M Wilson; Peder E Z Larson; John Kurhanewicz; Robert R Flavell
Journal:  Magn Reson Med       Date:  2019-05-03       Impact factor: 4.668

2.  Multi-sample measurement of hyperpolarized pyruvate-to-lactate flux in melanoma cells.

Authors:  Hannah Lees; Micaela Millan; Fayyaz Ahamed; Roozbeh Eskandari; Kristin L Granlund; Sangmoo Jeong; Kayvan R Keshari
Journal:  NMR Biomed       Date:  2020-12-12       Impact factor: 4.044

3.  Longitudinal Measurements of Intra- and Extracellular pH Gradient in a Rat Model of Glioma.

Authors:  Heeseung Lim; Mohammed Albatany; Francisco Martínez-Santiesteban; Robert Bartha; Timothy J Scholl
Journal:  Tomography       Date:  2018-06
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.