A Robust and Affordable Table Indexing Approach for Multi-isocenter Dosimetrically Matched Fields.

Amy Yu1, Benjamin Fahimian1, Lynn Million1, Annie Hsu1.   

Abstract

Purpose  Radiotherapy treatment planning of extended volume typically necessitates the utilization of multiple field isocenters and abutting dosimetrically matched fields in order to enable coverage beyond the field size limits. A common example includes total lymphoid irradiation (TLI) treatments, which are conventionally planned using dosimetric matching of the mantle, para-aortic/spleen, and pelvic fields. Due to the large irradiated volume and system limitations, such as field size and couch extension, a combination of couch shifts and sliding of patients are necessary to be correctly executed for accurate delivery of the plan. However, shifting of patients presents a substantial safety issue and has been shown to be prone to errors ranging from minor deviations to geometrical misses warranting a medical event. To address this complex setup and mitigate the safety issues relating to delivery, a practical technique for couch indexing of TLI treatments has been developed and evaluated through a retrospective analysis of couch position. Methods The indexing technique is based on the modification of the commonly available slide board to enable indexing of the patient position. Modifications include notching to enable coupling with indexing bars, and the addition of a headrest used to fixate the head of the patient relative to the slide board. For the clinical setup, a Varian Exact CouchTM (Varian Medical Systems, Inc, Palo Alto, CA) was utilized. Two groups of patients were treated: 20 patients with table indexing and 10 patients without. The standard deviations (SDs) of the couch positions in longitudinal, lateral, and vertical directions through the entire treatment cycle for each patient were calculated and differences in both groups were analyzed with Student's t-test. Results The longitudinal direction showed the largest improvement. In the non-indexed group, the positioning SD ranged from 2.0 to 7.9 cm. With the indexing device, the positioning SD was reduced to a range of 0.4 to 1.3 cm (p < 0.05 with 95% confidence level). The lateral positioning was slightly improved (p < 0.05 with 95% confidence level), while no improvement was observed in the vertical direction. Conclusions The conventional matched field TLI treatment is error-prone to geometrical setup error. The feasibility of full indexing TLI treatments was validated and shown to result in a significant reduction of positioning and shifting errors.

Entities:  

Keywords:  dosimetric match fields; safety; shift error; table indexing; tli

Year:  2017        PMID: 28652953      PMCID: PMC5481188          DOI: 10.7759/cureus.1270

Source DB:  PubMed          Journal:  Cureus        ISSN: 2168-8184


  12 in total

Review 1.  Facilitation of radiotherapeutic error by computerized record and verify systems.

Authors:  Gregory A Patton; David K Gaffney; John H Moeller
Journal:  Int J Radiat Oncol Biol Phys       Date:  2003-05-01       Impact factor: 7.038

2.  Effect of a carbon fiber tabletop on the surface dose and attenuation for high-energy photon beams.

Authors:  Tülay P Meydanci; Gönül Kemikler
Journal:  Radiat Med       Date:  2008-11-22

3.  The matching of adjacent fields in radiotherapy.

Authors:  D I Armstrong; J J Tait
Journal:  Radiology       Date:  1973-08       Impact factor: 11.105

4.  Physical and dosimetric aspects of the radiotherapy of malignant lymphomas. II. The inverted-Y technique.

Authors:  V Page; A Gardner; C J Karzmark
Journal:  Radiology       Date:  1970-09       Impact factor: 11.105

5.  Physical and dosimetric aspects of the radiotherapy of malignant lymphomas. I. The mantle technique.

Authors:  V Page; A Gardner; C J Karzmark
Journal:  Radiology       Date:  1970-09       Impact factor: 11.105

6.  A computerized record and verify system for radiation treatments.

Authors:  R Mohan; K C Podmaniczky; R Caley; A Lapidus; J S Laughlin
Journal:  Int J Radiat Oncol Biol Phys       Date:  1984-10       Impact factor: 7.038

7.  Immunosuppression and tolerance after total lymphoid irradiation (TLI).

Authors:  S Strober; M Gottlieb; S Slavin; D P King; R T Hoppe; Z U Fuks; C P Bieber; H S Kaplan
Journal:  Transplant Proc       Date:  1980-09       Impact factor: 1.066

8.  Reproducibility of patient positioning for fractionated extracranial stereotactic radiotherapy using a double-vacuum technique.

Authors:  Meinhard Nevinny-Stickel; Reinhart A Sweeney; Reto J Bale; Andrea Posch; Thomas Auberger; Peter Lukas
Journal:  Strahlenther Onkol       Date:  2004-02       Impact factor: 3.621

9.  Site-specific tolerance tables and indexing device to improve patient setup reproducibility.

Authors:  Kiernan T McCullough; Joshua A James; Ashley J Cetnar; Mark A McCullough; Brian Wang
Journal:  J Appl Clin Med Phys       Date:  2015-05-08       Impact factor: 2.102

10.  Analysis of couch position tolerance limits to detect mistakes in patient setup.

Authors:  Scott W Hadley; James M Balter; Kwok L Lam
Journal:  J Appl Clin Med Phys       Date:  2009-10-29       Impact factor: 2.102

View more
  1 in total

1.  A method to predict patient-specific table coordinates for quality assurance in external beam radiation therapy.

Authors:  Daniel L Saenz; Nestor Rodrigo Astorga; Neil Kirby; Mohamad Fakhreddine; Karl Rasmussen; Sotirios Stathakis; Niko Papanikolaou
Journal:  J Appl Clin Med Phys       Date:  2018-08-07       Impact factor: 2.102

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.