| Literature DB >> 28652817 |
Jéssica Dias Theobaldo1, Flávio Henrique Baggio Aguiar1, Núbia Inocencya Pavesi Pini2, Débora Alves Nunes Leite Lima1, Priscila Christiane Suzy Liporoni3, Anderson Catelan3.
Abstract
OBJECTIVE: The aim of this study is to evaluate the effect of composite preheating and polymerization mode on degree of conversion (DC), microhardness (KHN), plasticization (P), and depth of polymerization (DP) of a bulk fill composite.Entities:
Keywords: composite resins; hardness; heating; physicochemical phenomena; polymerization
Year: 2017 PMID: 28652817 PMCID: PMC5477166 DOI: 10.2147/CCIDE.S130803
Source DB: PubMed Journal: Clin Cosmet Investig Dent ISSN: 1179-1357
Means (SD) of degree of conversion (%) of composites in terms of light-curing unit, preheating temperature, and surface analyzed
| Curing unit | Temperature (°C) | Surface
| Polled data | |
|---|---|---|---|---|
| Top | Bottom | |||
| LED | 23 | 85.63 (2.12) (Aa) | 81.09 (2.11) (Bb) | 84.18 (2.75) |
| 54 | 85.92 (2.11) (Aa) | 84.16 (2.13) (Aa) | ||
| QTH | 23 | 80.90 (1.96) (Aa) | 79.97 (1.07) (Bb) | 81.65 (2.01) |
| 54 | 82.83 (1.76) (Aa) | 82.90 (1.79) (Aa) | ||
| Control | 66.99 (1.25) | 65.82 (2.05) | ||
Notes: Distinct capital letters comparing the top and bottom surface and the lower case letters comparing the different preheating temperatures within each curing unit are statistically different (p ≤ 0.05).
Differs from QTH unit (p ≤ 0.05).
Differs from control group (p ≤ 0.05).
Abbreviations: SD, standard deviation; LED, light-emitting diode; QTH, quartz–tungsten–halogen.
Means (SD) of Knoop hardness number (KHN, kg F/mm2) and plasticization (%KHNRed) of composites in terms of light-curing unit, preheating temperature, and surface analyzed
| Curing unit | Temperature (°C) | Microhardness
| Plasticization
| ||
|---|---|---|---|---|---|
| Top | Bottom | Top | Bottom | ||
| LED | 23 | 49.15 (6.10) (Aa) | 47.40 (5.22) (Ba) | 71.54 (2.49) (Aa) | 78.34 (3.41) (Ba) |
| 54 | 48.88 (3.39) (Aa) | 48.39 (5.07) (Ba) | 71.47 (8.40) (Aa) | 78.92 (2.59) (Ba) | |
| QTH | 23 | 49.24 (7.12) (Aa) | 44.60 (3.55) (Ba) | 74.19 (5.16) (Aa) | 74.98 (0.89) (Ba) |
| 54 | 47.20 (5.67) (Aa) | 43.54 (3.25) (Ba) | 73.12 (3.65) (Aa) | 78.31 (2.06) (Ba) | |
| Control | 52.72 (2.56) | 52.58 (2.84) | 47.96 (4.23) | 53.88 (1.70) | |
Notes: Distinct capital letters comparing the top and bottom surfaces and the lower case letters comparing the different preheating temperatures within each curing unit are statistically different (p ≤ 0.05) for each assay performed.
Differs from control group (p ≤ 0.05).
Abbreviations: SD, standard deviation; LED, light-emitting diode; QTH, quartz–tungsten–halogen.
Means (SD) of depth of polymerization of composites in terms of light-curing unit and preheating temperature
| 23 °C | 54 °C | |
|---|---|---|
| LED | 0.97 (0.06) | 0.99 (0.10) |
| QTH | 0.92 (0.13) | 0.93 (0.07) |
| Control | 1.00 (0.04) |
Notes: There was no statistical difference between light-curing units, preheating temperatures, and experimental groups compared to control group (p > 0.05).
Abbreviations: SD, standard deviation; LED, light-emitting diode; QTH, quartz–tungsten–halogen.