VFQ-25 subscale scores for scleral buckle and pneumatic retinopexy
| VFQ-25 subscale score | Mean (standard deviation)
| 95% confidence interval of the difference
| |||
|---|---|---|---|---|---|
| Scleral buckle (N=31) | Pneumatic retinopexy (N=28) | Lower | Upper | ||
| General health | 66.9 (25.3) | 73.2 (25.4) | −19.5 | 7.0 | 0.35 |
| General vision | 71.8 (14.3) | 75.7 (15.7) | −11.7 | 3.9 | 0.33 |
| Ocular pain | 76.6 (23.9) | 82.6 (21.1) | −17.8 | 5.8 | 0.31 |
| Near activities | 79.3 (21.4) | 75.1 (20.7) | −6.8 | 15.1 | 0.45 |
| Distance activities | 77.6 (21.0) | 81.0 (20.0) | −14.1 | 7.3 | 0.53 |
| Social functioning | 89.9 (20.0) | 92.0 (17.1) | −11.8 | 7.7 | 0.68 |
| Mental health | 71.4 (28.5) | 79.0 (24.0) | −21.5 | 6.2 | 0.27 |
| Role difficulty | 72.7 (20.2) | 77.2 (25.9) | −16.5 | 7.5 | 0.46 |
| Dependency | 88.0 (24.3) | 90.6 (24.1) | −15.2 | 10.1 | 0.68 |
| Driving | 74.9 (21.3) | 75.0 (27.0) | −12.8 | 12.5 | 0.98 |
| Color vision | 94.8 (16.4) | 93.3 (16.1) | −7.0 | 9.9 | 0.73 |
| Peripheral vision | 71.5 (28.7) | 72.3 (28.3) | −15.8 | 14.0 | 0.91 |
Notes: The VFQ-25 consists of 25 questions that ask the patient to rate their general health and vision, the difficulty of completing different tasks because of vision limitations, and how well they have responded to their level of vision. Questions are assigned to one of 12 subscales. Each item is translated to a score from 0 to 100, with 100 being the best functioning. Scores from questions within each subscale are averaged together to create a score from 0 to 100 for each subscale. Finally, a composite score for the VFQ-25 is calculated by averaging all of the subscale scores, except the general health rating question. No significant differences were found for any of the subscale scores.
Abbreviation: VFQ-25, National Eye Institute Visual Function Questionnaire-25.
Additional question scores for scleral buckle and pneumatic retinopexy
| Additional questions | Mean (standard deviation)
| 95% confidence interval of the difference
| |||
|---|---|---|---|---|---|
| Scleral buckle (N=29) | Pneumatic retinopexy (N=26) | Lower | Upper | ||
| Difficulty with activities | 2.9 (1.9) | 2.7 (2.1) | −0.8 | 1.4 | 0.61 |
| Limitations | 2.7 (1.8) | 2.8 (2.2) | −1.2 | 0.9 | 0.78 |
| Pain | 2.3 (2.4) | 2.0 (2.2) | −0.9 | 1.5 | 0.62 |
| Early pain | 4.2 (3.0) | 3.7 (2.6) | −1.0 | 2.1 | 0.49 |
| Pain 48 hours postoperative | 5.3 (3.1) | 4.4 (3.2) | −0.8 | 2.6 | 0.29 |
| Difficulty postoperative | 5.3 (2.8) | 4.9 (3.0) | −1.2 | 1.9 | 0.66 |
| Resume normal activity (weeks) | 3.4 (1.5) | 3.1 (1.2) | −0.5 | 1.0 | 0.46 |
| Choosing the same operation (%) | 59 | 85 | NA | NA | 0.06 |
Notes: Eight questions were added to the VFQ-25 in order to create a modified survey targeted to patients who have undergone retinal detachment procedures. Scores ranged from 1 to 10, with higher numbers indicating increased difficulty or pain. No significant differences were found for any of the questions, but chi-squared analysis revealed a trend toward a higher percentage of patients choosing the same procedure for their fellow eye in the pneumatic retinopexy group compared to the scleral buckle group (P=0.06).
Abbreviations: VFQ-25, National Eye Institute Visual Function Questionnaire-25; NA, not applicable.