Literature DB >> 28646721

Biochemical-immunological hybrid biosensor based on two-dimensional chromatography for on-site sepsis diagnosis.

Seung-Wan Kim1, Il-Hoon Cho2, Guei-Sam Lim3, Gi-Na Park1, Se-Hwan Paek4.   

Abstract

A hybrid-biosensor system that can simultaneously fulfill the immunoassay for protein markers (e.g., C-reactive protein (CRP) and procalcitonin (PCT)) and the enzyme assay for metabolic substances (e.g., lactate) in the same sepsis-based sample has been devised. Such a challenge was pursued through the installation of an enzyme-reaction zone on the signal pad of the typical immuno-strip for the rapid two-dimensional (2-D)-chromatography test. To minimize the mutual interference in the hybrid assays, a pre-determined membrane site was etched in a pattern and mounted with a biochemical-reaction pad, thereby allowing a loaded sample to enter and then stay in the pad for a colored-signal production over the course of an immunoassay. By employing such a constructed system, a serum sample was analyzed according to the vertical direction flowing along the strip, which supplied lactate to the biochemical-reaction zone and then protein markers to the immunological-binding area that was pre-coated with capture antibodies. Thereafter, the enzyme-signal tracers for the immunoassay and the substrate solution were sequentially furnished using a horizontal path for the tracing of the immune complexes that were formed with CRP or PCT. The color signal that was produced from each assay was detected at a pre-determined time and quantified on a smartphone-based detector. Under the optimal conditions, the dynamic ranges for the analytes covered the respective clinical ranges, and the total coefficient of variation was between 8.6% and 13.3%. The hybrid biosensor further showed a high correlation (R2 > 0.95) with the reference systems for the target markers.
Copyright © 2017 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Heterogeneous analytes; Multiplexed biosensing; Rapid sepsis diagnosis; Smartphone detector; Two-dimensional chromatography

Mesh:

Substances:

Year:  2017        PMID: 28646721     DOI: 10.1016/j.bios.2017.06.032

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  4 in total

1.  Simultaneous Detection of Inflammatory Biomarkers by SERS Nanotag-Based Lateral Flow Assay with Portable Cloud Raman Spectrometer.

Authors:  Yang Li; Xiaojia Liu; Jiuchuan Guo; Yueting Zhang; Jinhong Guo; Xinggui Wu; Bo Wang; Xing Ma
Journal:  Nanomaterials (Basel)       Date:  2021-06-05       Impact factor: 5.076

Review 2.  Micro- and nanosensors for detecting blood pathogens and biomarkers at different points of sepsis care.

Authors:  Alejandra Alba-Patiño; Andreu Vaquer; Enrique Barón; Steven M Russell; Marcio Borges; Roberto de la Rica
Journal:  Mikrochim Acta       Date:  2022-01-26       Impact factor: 5.833

3.  A simple and compact smartphone-based device for the quantitative readout of colloidal gold lateral flow immunoassay strips.

Authors:  Wei Xiao; Caihong Huang; Fei Xu; Junjie Yan; Hongfen Bian; Qiangqiang Fu; Kaixin Xie; Lei Wang; Yong Tang
Journal:  Sens Actuators B Chem       Date:  2018-03-20       Impact factor: 7.460

Review 4.  The Role of Soft Robotic Micromachines in the Future of Medical Devices and Personalized Medicine.

Authors:  Lourdes Garcia; Genevieve Kerns; Kaitlin O'Reilley; Omolola Okesanjo; Jacob Lozano; Jairaj Narendran; Conor Broeking; Xiaoxiao Ma; Hannah Thompson; Preston Njapa Njeuha; Drashti Sikligar; Reed Brockstein; Holly M Golecki
Journal:  Micromachines (Basel)       Date:  2021-12-26       Impact factor: 2.891

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.